How to replace heater switch
F51
Heater pressure switch
The program is interrupted and the drain pump is operated. The display
shows Technical fault F51. Call Service Department. The buzzer is
activated for 2 minutes.
Background information:
Start position:
One second after the program start, heater relay K1/1 is activated. This
enables a check as to whether the contacts on heater pressure switch B1/13
have closed on switching steps 21/22 or 11/12.
Cause:
Heater relay defective; contact open.
Remedy:
Replace the heater relay.
Cause:
Heater relay solenoid defective.
Remedy:
Replace the heater relay.
Cause:
Connection from heater relay to electronic module open-circuited.
Remedy:
1. Check plug connections.
2. Check the connection wires for continuity.
Cause:
Heater pressure switch open- or short-circuited.
Remedy:
Replace the heater pressure switch.
Cause:
Connection from heater pressure switch to electronic open-circuited.
Remedy:
1. Check plug connections.
2. Check the connection wires for continuity.
Cause:
Foreign objects in heater pressure switch.
Remedy:
Replace the heater pressure switch