Problems with my bonaire evap

The problem is it keeps releasin the water so it just blows hot air and the water just runs down the drain,

Posted by on

2 Answers

  • Level 1:

    An expert who has achieved level 1.


    An expert whose answer got voted for 2 times.

  • Contributor
  • 1 Answer
Re: problems with my bonaire evap

Air con keeps shuting down takes about an hour before its cranks back up.

Posted on Jan 03, 2009

  • Level 2:

    An expert who has achieved level 2 by getting 100 points


    An expert who has answered 20 questions.


    An expert that has over 10 points.


    An expert whose answer got voted for 2 times.

  • Expert
  • 86 Answers
Re: problems with my bonaire evap - Air Conditioners

Compressure not working

Posted on Mar 17, 2008

Add Your Answer

0 characters

Uploading: 0%


Complete. Click "Add" to insert your video. Add


3 Points

Related Questions:

1 Answer

After switching on the ac unit water start dripping

I assume inside the air handler closet, underneath the unit, or wherever unit is located.
Sounds like condensate line is stopped up.
You need to blow out with compressed air. You must make sure that you block air from exiting from open end of line. I use a plastic shopping sack. May have to remove cover to evaporator and insert hose in condensate drain connection in drain pan. Stuff the bag in around hose and opening to seal and blast air into line. Be sure that if there is a "T" fitting with riser and cap on the end, that it is secure, otherwise you may get a shower. You also may use the riser with the cap remove to blow out. insert hose past opening leading back to evaporator drain push bag down past opening leading back to evap drain, then seal around inserted hose and blast. The riser with the cap is where you would pour some bleach every couple of months to keep line clear.

Aug 24, 2013 | Hitachi Air Conditioners

1 Answer

A6K32E7C part number for kit to keep water from blowing out thru the evaporator

you may just need to pull the unit out and clean the small drain pipe that goes from the evap pan its the pan under the front coil and should drain toward the back of the a/c toward the condensor coil ..the coil on the back of the unit

Sep 30, 2010 | Fedders A6K32E7C Thru-Wall/Window Air...

2 Answers

Our Bonaire Evap Cooler stopped after power failure

Turn the power of to both the heater and the cooler. Turn the power back on to the heater and the cooler at the same time then reset codes on controller.

Feb 07, 2010 | Mastercool 67471 Evaporative Cooler Air...

1 Answer

Dimplex leaks from the bottom front

Hi, I have been through this many times. Locate the drain lines on the units. Check the filters and if they are foam, wash them in your sink. You will need to clean the drain hoses out as the have something in them, dirt build up most likely. If they have a drain trough for the condensation to drain to the hose, clean this also. If you have no compressed air tank to blow them out, you can try and lay something down to keep things dry, and try and poor hot water down the drains to open them up. Your best bet would be to spend $14.00 dollars and buy an air tank that comes with a hose and nozzle. Fill it with air and blow them out. This will solve this condensation problem. Best of luck to you, and happy Holidays,

Dec 16, 2009 | Air Conditioners

1 Answer

Vulcan bonair evaperative cooling unit will not operaate when switched on

If shut down at end of season by air con person may be switched off in roof unit. just remove one side and should have switch in unit usually near pump

Nov 01, 2009 | Mastercool 67471 Evaporative Cooler Air...

2 Answers

Ive got a mildewy smell coming from my evaporative cooler how do i get rid of it?

This unit needs to be serviced. Try replacing the pads with the sponge like pads.Drain the old water and clean up the pan and pump area. Go down to a pool supply store and buy some chlorine tablets and add to the water. In fact, they make these tablets just for the evaporator units. There are 3 states to water, solid, liquid and gas,
. This will get rid of the smell.
Sincerely, shastalaker7

Oct 28, 2009 | Mastercool 67471 Evaporative Cooler Air...

1 Answer

Compressor problem

sounds to me like the capacitor is no good.

Aug 23, 2008 | Goodman CKL60AR60 Air Conditioner

2 Answers

Thru wall GE A/C

Hi, If this is a new unit I would check the filter first and make sure it is clean. Also check and make sure it is slightly tilted to the outside. If its an older unit it probably needs cleaned. Window units naturally create water in the evaporator area. The water is suppose to drain to the back of the unit to the condensing area where the slinger ring on the condenser fan blade slings it into the condenser coil making it more efficient. There is usually a drain hole to drain excess water from the back of the unit. Any dirt in the pathway of this water or the wrong tilt will cause water to build up and drip or blow out the front. Anything touching the evaporator coil allowing water to run down the obstacle into the wrong area will cause the same thing. reduced air flow will cause the evap to freeze which could also cause a water problem.

Aug 27, 2007 | Air Conditioners

Not finding what you are looking for?
Air Conditioners Logo

Related Topics:

426 people viewed this question

Ask a Question

Usually answered in minutes!

Top Air Conditioners Experts

Mike Butler
Mike Butler

Level 3 Expert

6674 Answers


Level 3 Expert

1033 Answers

Dan Webster
Dan Webster

Level 3 Expert

8147 Answers

Are you an Air Conditioner Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides