My compressor works itermittantly. I was holding suction line to see if it felt cold. It felt kinda cool. Then all of a sudden it went COLD. A minute or two later it was kinda cool again. Could my compressor motor be going off and on. If so, could a hard start kit help? Motor is cscr. Its on a Goodman 2 ton, r22 unit. Model ck24-1

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 614 Answers

A hard start kit always helps. Take a reading inside. Temp at the return air and temp at the closest grille. Subtract and that temp should be between 19 to 23 degrees. If not you have other problems. Contact service tech for free estimate. Possibly a little low on refigerat, Rus

Posted on Jul 05, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

AC compressor clicks on and off while running?


the compressor will cycle on/off when the cabin temperature is reached
the larger pipe will be cold to touch as it is the suction line for the compressor
if you have a problem with the ac ,it will not work the compressor at all and the lines will not get cold
When in doubt take it to an accredited ac specialist shop and have the system check out.

Aug 11, 2015 | 2000 Cadillac Escalade

1 Answer

Mitsubishi ac keeps on turning itself off


If the compressor overheats, the clixon circuit will shut off the power to the motor to prevent damage. Then when it cools it will close the circuit and the compressor will again run to only shut down again.
The suction line going to the compressor should be cold - the cold gas returning to unit cools the hermetically sealed motor. If that line is hot you may be low on refrigerant.

Feb 19, 2014 | Heating & Cooling

1 Answer

HVAC American Allegiance 11 not cooling


The low and high pressure lines temperatures are backwards the large one should be cold and the small one should be warm. Sounds like a piston issue may be a restriction in the suction line

Jul 28, 2012 | Heating & Cooling

1 Answer

After installing my Klimaire 30912-H216 mini split, one of the three evaporators is cooling but not as much as the other two.


actually the hi side smaller line should be hot to the touch and the low side larger line should be cool or cold, sounds like a low charge without any further information, the small line coming off the compressor is the liquid compressed it should be hot, the large line low side returning to the compressor is the gas after the coils and returning it should be cool or cold depending on load

Jul 06, 2012 | Heating & Cooling

1 Answer

8 year old side by side, refrigerator and freezer not cold, compressor running, condenser fan running, discarge line not hot suction line not cold


discharge line not hot suction line not cold. This indicates the compressor is not working properly. It could be out of freon or just not pumping.

Nov 03, 2010 | Maytag Refrigerators

1 Answer

I have a kemore coldspot side by side maufacture date 04/07 that is not cooling properly. Freezer gets cold but won't freeze and fridge section gets cool. I have checked condenser fan runs and compressor...


Hi,

Many times a freezer and/or refrigeratordo not work right because of a dirty condenser coil...there are also many otherthings that can go wrong. If you are hearing a clicking or buzzing then check out thelast two tips.

If your refrigerator is running but warm, then...

Check out these tips that I wrote about that... it is a great place to starttrouble shooting your unit...and something that you can do rather then callinga repair person to do a simple thing for you...

Refrigerator Condenser Coil Cleaning Refrigerator Repair

Refrigerator Troubleshooting Refrigerator Compressor

Refrigerator Compressor Start Capacitor and Start Relay
Refrigerator or Freezer not Cooling or Getting Cold

heatman101

Oct 24, 2010 | Kenmore 53642 / 53644 Side by Side...

1 Answer

Both the freezer and refrigerator are warm (Superba model). This happened all of the sudden. I felt the tank and lines at the back and the tank was hot and the lines were not cold. The fan motor is blowing...


Hi,

Many times a freezer and/or refrigerator do not work right because of a dirty condenser coil...there are also many other things that can go wrong.


If you are hearing a clicking or buzzing then check out the last two tips.

If your refrigerator is running but warm, then...

Check out these tips that I wrote about that... it is a great place to start trouble shooting your unit...and something that you can do rather then calling a repair person to do a simple thing for you...

Refrigerator Condenser Coil Cleaning Refrigerator Repair

Refrigerator Troubleshooting Refrigerator Compressor

Refrigerator Compressor Start Capacitor and Start Relay


Refrigerator or Freezer not Cooling or Getting Cold

heatman101
///////////////

Sep 01, 2010 | KitchenAid Superba Architect KSCS25INSS...

1 Answer

Liquid line is cool coming from condenser indoor air not cold enough. Unit runs constantly at temps of 90 to maintain 80 inside


If the compressor is running at 90 there should be hot air coming out of the condensing units fan, if not it could be damaged valves in the compressor especially if the suction line is colder than normal like ice cold.
Obviously if the compressor is not running then you have other electrical problems.

Jun 02, 2010 | Bryant 463AAC005BA Air Conditioner

Not finding what you are looking for?

Open Questions:

Heating & Cooling Logo

Related Topics:

127 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2463 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...