Fluidmaster Water Saving Easy Fix 400 400EZi-LS Logo
Rick Molen Posted on Sep 01, 2014

Fluidmaster 400 manual

Whenever the water gets below the waterline the toilet will make a noise that produces air bubbles and brings the tank back to the level of the waterline ? What can be done to fix this ?

1 Answer

Richard Delisle

Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Corporal:

An expert that hasĀ over 10 points.

Problem Solver:

An expert who has answered 5 questions.

  • Contributor 6 Answers
  • Posted on Mar 22, 2015
Richard Delisle
Contributor
Level 1:

An expert who has achieved level 1.

New Friend:

An expert that has 1 follower.

Corporal:

An expert that hasĀ over 10 points.

Problem Solver:

An expert who has answered 5 questions.

Joined: Mar 19, 2015
Answers
6
Questions
1
Helped
5834
Points
13

Why is the water leaking out of the tank? There's only reason for that, the water is slowly leaking by the plunger.check the plunger aT The bottom of the tank it's activated by the handle.shut the water supply off empty the tank,clean the bottom of the plunger refill tank .problem should be fixed if not replace plunger.. Happy plumbing.

  • Richard Delisle Mar 22, 2015

    Why is the water leaking out of the tank? There's only reason for that, the water is slowly leaking by the plunger.check the plunger aT The bottom of the tank it's activated by the handle.shut the water supply off empty the tank,clean the bottom of the plunger refill tank .problem should be fixed if not replace plunger.. Happy plumbing.

×

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

I installed brand new Kohler toilet w/ a Fluidmaster float. From the beginning the tank empties just enough to fill back up. I also noticed air bubbles on bolt caps and the rest of the parts.

Check the flapper and seat. Ensure that the flapper chain is not tight or caught underneath flapper. Check floor underneath tank for any sighs of water leaking or seeping from tank. tight tank to bowl nuts. good luck
Apr 03, 2018 • Kohler Home
0helpful
1answer

Fluidmaster

First shut water off at stop than flush all the water out of the tank next take a sponge and get all the water out of tank next unsrew the supply line from the valve under tank than move out of the way next unsrew the nut on the valve of fluidmaster than pull the fluidmaster out of tank stick the new fluidmaster in tighten nut srew the supply line back on turn on stop and let the tank fill up thats it if the fluidmaster dont shut off press the handle let some water out and adjust the fluidmaster screw Tip the water should stop a 1/4 inch below the flush valve tube in center of toilet
0helpful
1answer

What do I do if the toilet continues to draw water and the water level on the fluidmaster 400 is properly set?

First is the water overflowing the overflow tube? This would indicate that the ballcock or flow master needs a seal or that it is rubbing the side of the tank (if it is rubbing the side of the tank twist it slightly). If the water level is always below the top of the tube but the flow master keeps on filling in bursts then you need to replace the flapper. Flappers will decompose slowly and black residue will come off to the touch. Wear gloves because this black will be on your hands for days. The flapper gets a slight ripple or curve that allows water to get by.
0helpful
1answer

Fluidmaster 400

Change flush valve, it comes with tank to toilet gasket, which sounds like your problem.

If you need further help, reach me via phone at https://www.6ya.com/expert/frankie_091f536560a54e12

Aug 11, 2013 • Plumbing
0helpful
1answer

Brand new fluidmaster 400 installed but toilet still leaking

Is The water leaking in or out check the stopper is good and that it is seating right
8helpful
2answers

My fluidmaster 400 anti siphon for toilet will not stop filling making pump run over and over

Hi turtlerose07...

Sounds like you have one or two problems with the fluidmaster 400.
1...The float is set too high allowing the water to overflow into the overflow pipe and allowing your pump to run too much.
2...Flapper valve inside at the bottom of the tank is not sealing properly, thus allowing water to leak and causing the fluidmaster to keep trying to fill the tank with water and causing the pump to run too much.
Please take time to rate me
Aug 24, 2011 • Home
0helpful
2answers

We replaced our 3 toilets with the Fluidmaster 400 and have had problems ever since. All the toilets are running water every 5 to 10 minutes and my water bill has doubled. What can we do?

Hello- If you replaced old ball and rod set with new fluidmasters they will most likely need to be adjusted, not all toilet tanks are of equal height. You will have to adjust water height,meaning you must keep water level below fill tube located in center of the toilet tank. Adjustment is done from bottom of the fluidmaster, they screw in and out to adjust height. You will notice threads along the bottom part of the fluid master, on the inside of the tank,they adjust up & down! Goodluck!
May 19, 2011 • Home
0helpful
2answers

I installed a new complete Fluidmaster and filled it up with water but when flushing water comes out under the tank not under the toilet though.

probably needs a "doughnut" tank washer under tank..or try tightening the tank bolt..fluid master comes with a little rubber hose that goes to overflow tube
0helpful
1answer

The lever must be held all the way down until all water leaves toilet or toilet does not flush and re-fill

Have you recently replaced the fill valve and flapper ?If so make sure they are interchagable and can produce close to the same GPF as original hardware.Fluidmaster has a tall tube that can be cut according to tank depth to accomidate water volume in tanksome times a little more water volume will do the trick.Also make sure flapper is staying open long enough to produce the required results.
1helpful
1answer

I have installed a fluidmaster 400 bottom inlet

I have installed 400A or 400LS valves on systems as low as 30psi, but below that I don't know that it would work very well if you needed it to fill faster.

Keep in mind that your pressure to the toilet will be 1/2psi for every foot above the fill level of the tank, which is reduced by friction loss in the pipe and fittings on the way to the toilet.
Not finding what you are looking for?

1,548 views

Ask a Question

Usually answered in minutes!

Top Fluidmaster Home Experts

john h

Level 3 Expert

29494 Answers

Brad Brown

Level 3 Expert

19187 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66957 Answers

Are you a Fluidmaster Home Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides