Casio TE-2000 Cash Register Logo
B
Bikash Posted on Aug 26, 2014

Need help.... I reached the point where the register read IPL 0000 and I could not find any way to get out of this mode. So, I just pulled the plug. Now plugging the register back in, it does nothing and no display. When I connect the power line some LCD's light on for fraction of second and a blank screen. Please let me know how to fix this. I was trying to program it using cv-22 and was getting 198 error. Then some how went to IPL 0000 mode. I will appreciate any help you could provide.

1 Answer

John Sheehan

Level 1:

An expert who has achieved level 1.

MVP:

An expert that got 5 achievements.

New Friend:

An expert that has 1 follower.

Hot-Shot:

An expert who has answered 20 questions.

  • Contributor 28 Answers
  • Posted on Aug 27, 2014
John Sheehan
Contributor
Level 1:

An expert who has achieved level 1.

MVP:

An expert that got 5 achievements.

New Friend:

An expert that has 1 follower.

Hot-Shot:

An expert who has answered 20 questions.

Joined: Aug 27, 2014
Answers
28
Questions
0
Helped
8624
Points
67

This is a communication error. There are two thpes os serial cable. You are using a straight thru cable you need a "null modem cable or you will get no communication. Confirmed. our serial cable needs to be a crossover "null Modem" type if I remember correctly. you probably have a straight through cable which wont work. Also make sure you are using the correct port number for your serial converter (often port 4). Check it in device manager.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
1answer

I have te-2400 frozen ... lcd works not showing any digits ... anyone can help

You have halted the firmware due to a failure to load IPL. This is recoverable if you do a hard reset. See your service and programming manuals for hard reset and IPL instructions. Make sure you have the correct IPL and loader for your region. If you don't need to replace the IPL then do not attempt it
tip

How to fix Blank Device manager

RESOLUTION:
==========

----------------------------------------------------------------------
CREATE A RESTORE POINT BEFORE ANY OF THESE STEPS
----------------------------------------------------------------------

STEP 1:
======
Check if Plug and Play service is started.Check the settings of the same in the
registry

HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\PlugPlay

ImagePath = %SystemRoot%\system32\services.exe
ObjectName = LocalSystem
PlugPlayServiceType = 3
Start = 2
Type = 20

STEP 2:
======
Advanced cleanboot (316434) and Hardware cleanboot (SOX051008700004)

STEP 3:
======
System restore (306084)
If we know when the issue started, read the system restore point information for
that day prior to trying the restore

STEP 4:
======
Look for the update KB905749 and try uninstalling it. Be sure to shut the system
down and wait 10 seconds before restarting.

STEP 5:
======
Go to safe mode - check for bangs in hidden devices in System devices - Uninstall
PnP BIOS Extension and any other device having a bang

STEP 6:
======
- Follow SOX041029700032
check the permissions on
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Enum
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Enum\Root
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Enum\Root\LEGACY_RASAUTO
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Enum\Root\LEGACY_RASAUTO\0000
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Enum\Root\LEGACY_RASAUTO\0000\Control
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Enum\Root\LEGACY_RASMAN
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Enum\Root\LEGACY_RASMAN\0000
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Enum\Root\LEGACY_RASMAN\0000\Control
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Enum\Root\LEGACY_TAPISRV
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Enum\Root\LEGACY_TAPISRV\0000
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Enum\Root\LEGACY_TAPISRV\0000\Control

If Administrators is listed, then remove Administrators. The default permissions
for these keys are:

System : Full Control : This key and subkeys
Everyone : Read Only : This key and subkeys

Change the permissions so that they apply to "This key and subkeys" and not just
"This key only".

STEP 7:
======
We could try to register the following files
regsvr32 devmgr.dll
regsvr32 dmocx.dll
If the files are missing, extract a copy from Windows XP CD-ROM or the
ServicePackFiles folder

STEP 8:
======
Copy the following on a notepad.Save it as dev.reg.Double click on the same.Restart
the computer.
on May 03, 2010 • Computers & Internet
tip

Error code CANON iR2200 / iR2800 / iR3300 / IR3100

Normal 0 MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Обычная таблица"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman";} E000
0000
The reading of the main thermistor does not reach 30°C 1 sec after the main power switch is turned on. Or, it does not reach 70°C 2 sec thereafter.
E001
0000
The main thermistor detects 250°C or higher.
0001
The main thermistor or the sub thermistor detects overheating (hardware circuit detection).
0002
The sub thermistor detects about 295°C or higher.
E002
0000
The temperature of the fixing film is as follows:
· has exceeded 100°C, but does not reach 115°C within 1 sec thereafter.
· has exceeded 140°C, but does not reach 150°C within 1 sec thereafter.
· has exceeded 160°C, but does not reach 165°C within 1 sec thereafter.
E003
0000
The main thermistor reading is lower than 140°C when paper is moved.
0001
Low fixing temperature detection after standby (by sub thermistor)
E007
0000
An error in the rotation of the fixing film is detected.
The reading of the main thermistor is 100°C or higher and, in addition, the fixing film sensor does not detect the rotation of the film for 6 sec or more while the fixing motor is driven.

E010
0000
After the main motor drive signal is generated, the clock signal does to arrive within 1.3 sec.
1helpful
1answer

IPL fault, TE22000 how to troubleshoot?

Why were you trying to change the IPL? If you didn't have the new IPL and flashing software, you may have lost the firmware. Do you have the dealer IPL flashing software?
0helpful
1answer

How do I load the IPL to a CASIO TE-2400?

that is the correct way . Maybe you need to activate sdcard option on the new machine it could be off
0helpful
1answer

Hi, I have a few Casio TE-4500F cash registers, and I am trying to copy the programming from one of the registers to the others using a CF card. I seem to have managed to format the card and save the data...

Oh dear. Why are you wiping the IPL? You are seriously screwing up the firmware in the machine. It might be best to see a dealer to have them change IPLs for you
16helpful
2answers

Ipl for sharp cash register XE-A203 / XE-A213

MY NEW ELECTRONIC CASH REGISTER SHARP XE-A203 DSPLAYED IPL ON IT . WHAT DO I DO??
3helpful
1answer

Need a manual for UT 10781A saw

Illustrated (exploded) Parts list. They are a HUGE help with disassembly/reassembly. I did not see your IPL or I would have added link, but I have trouble finding anything on the Homelite site.
IPL will make oiler repair much simpler. https://register.homelite.com/contact_us/new
Give them a try. Good Luck.
Once you get the IPL post back with whether inboard or outboard clutch, I can help if oiler behind clutch. You know all oilers weep right? I have 7 saws all but 1 weep if I do not drain the tank.
I am going to close this. We can still converse.
Lou
0helpful
1answer

I have a problem with the Casio te-2200, the error IPL E02 displays on the and keyboard keys do not work, can anyone advise.

Oh dear. The IPL is the operating system, or firmware of the machine. It may end up needing a new IPL loaded into it. I have never had an IPL error without a good reason. However, you can try the basic things first. Open the cover on the side of the machine, and you will see the socket(s) for connecting PC, scanner etc. Also in there is a small hole (it may have a piece of tape over it). Inside the hole is a little button. Put something gently in the hole (while turned on), and press the button. The screen should change to show 'init' or '000000000' or both.
Now, turn power off at wall.
Turn the key to PROGRAM or PGM mode
Hold down RECEIPT FEED.
Turn on power at wall.
When you see the display change to 'FFFFFFFFFFF' let go of RECEIPT FEED, then press SUBTOTAL.
If the display does not change to 'FFFFFFFFFFF' then DO NOT press SUBTOTAL, just leave the machine, and message me again.

If all went well, turn back to REG mode, and try it.

Mark
0helpful
1answer

Casio TK-3200

Hi. IPLs can be tricky. Why do you need to load a new IPL? Is your scale one that is supported by the register? I would need to know everything you have tried. Also, don't forget, you must flag clear when you change any I/O settings, or they will not take effect.

Mark
Not finding what you are looking for?

182 views

Ask a Question

Usually answered in minutes!

Top Casio Retail Supplies Experts

Grand Canyon Tech
Grand Canyon Tech

Level 3 Expert

3867 Answers

Cindy Wells

Level 3 Expert

6688 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Casio Retail Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...