Question about Ecoquest Breeze AT Living Air Purifier

1 Answer

I have the same thing so ordered new ozone plate,

I had my unit for 5 years and never replaced the ozone plate.
Try that as I just ordered one from Ebay.

Posted by on

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 520 Answers

Try soaking the plate for a few minutes in ammonia ...it will bring these back to life

Posted on Jul 03, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have a Flair air puifier but no ozone smell. I replaced the high voltage transformer( it was a 3500 watt instead of a 5000 watt transformer) The red light now flickers but no ozone smell . It has ne


Your ozone generator may have gone bad. It's the small black rectangular looking apparatus located near the bottom of the unit. It usually has a zip tie holding it to the circuit board. You will have to take the Flair out of it's case to see it. Make sure it's unplugged and remove the bolt from the bottom of the unit. You can then slide the framework out of the casing. It's also possible that it's time to replace your Ceramic Ozone Plates. They have a life expectancy of 2 to 4 years. The Flair has two of them that slide into slots in the rear of the unit. You can see them when you remove the washable filter. All items can be purchased on Ebay. DM

Apr 28, 2012 | Ecoquest Flair Air Purifier

1 Answer

My xl15 runs but does not produce ozone. The little Rulien fan on the little ozone maker does not run. the regular fan works though.


You realize this is a really old machine!! The little fan is for ozone level detection, not production.
To see if the machine still will produce ozone
1) Set the switch to manual rather than auto and always run it on manual.
2) Remove the back of the machine and remove the 4" white plates. Check them for cracks, breaks in the mesh, loose mucilage, discoloration, burned spots, excessive grease or nicotine, or particulates such as dust, dog hair, or lint. Clean the plates using a solution of 1 part plain AMMONIA to 1 part warm water. Soak 5 minutes, brush with a soft brush, rinse well, and blow dry. DO NOT use any kind of cloth to dry the plate. Avoid putting fingers on the mesh.
3) If the plates are damaged in any way, call Vollara (new name for EcoQuest) and order replacements. 1-800-989-2299. Use #16618 as the dealer referral number if you are no longer in touch with the registered distributor who sold you the machine.
4) Insert the plates, making sure the metal contact fingers press on them firmly.
5) If none of the above works, most likely the power to those contact fingers is no longer strong enough to arc through the plates.
6) Call customer service, and they'll explain your options.

Feb 10, 2011 | Alpine Air XL-15 Air Purifier

1 Answer

My Breeze AT by EcoQuest , Model Breeze AT, Serial AT 125386, is sizzling the only ozone plate it has. A sizzling sound and a visual inspection shows it has a heavy concentration of voltage near the...


DO NOT USE IT WITH A DEFECTIVE PLATE!!!

It should be used with 2 plates. Order new plates IMMEDIATELY. They aren't too expensive, and hopefully will save your machine if it hasn't been damaged too severely.

Call Vollara (new name for EcoQuest) (1-800-989-2299) and use #16618 as your Dealer Referral number.

Jan 24, 2011 | Ecoquest Breeze AT Living Air Purifier

1 Answer

I no longer smell the ozone smell that i used too.


You probably have a burned out high voltage transformer. That's what produces the ozone. Helpful hint...........the high voltage transformer is also the one used in bug zappers.

May 29, 2010 | Ecoquest Breeze AT Living Air Purifier

1 Answer

I just purchased a used Alpine Air XL-15 from ebay.no ozone spell


You probably have a burned out high voltage transformer. That's what produces the ozone. Helpful hint...........the high voltage transformer is also the one used in bug zappers

May 10, 2010 | Alpine Air XL-15 Air Purifier

1 Answer

My Alpine Air XL-15 Air Purifier youst to have a


The Classic XL-15 should have 2 individual indicator lights. The 'red' light is the ionizer indicator, and the 'green' light is the ozone level indicator. Both lights should be illuminated, if the unit is operating properly. The red light should be pulsing, and the green light should be dimly lit, and brightened as the output knob is turned up - indicating a higher ozone production. If the green light is not lit, you likely won't smell the ozone. The first thing you should try, is cleaning the filter and glass ozone plate. Unplug the unit and remove the rear air filter. Clean the filter with clean water and allow to COMPLETELY air dry. Removed the glass plate by depressing the lever behind the glass plate, and gently pulling it out. Clean the glass with a half water, half ammonia (or distilled white vinegar, if ammonia not available) and an old toothbrush to clean between the mesh. Dry plate with a hair dryer and re-place plate into unit. Replace dried air filter, making sure the little tab on the bottom is secured into the interlock. Power the unit on and you should see the indicator lights and smell the fresh ozone!

Nov 14, 2009 | Alpine Air XL-15 Air Purifier

1 Answer

I have an ecoquest fresh air purifier and the end of a red wire was corroded so I replaced the end with a new one, but the unit doesnt seem to be producing any ozone smell or sanitizing. It seems as if...


That corrosion is oxidation for the lug connecting the grid plate.Metal contact fingers make contact on the plates metal grids.The same corrosion exists on those metal contact fingers and the plate itself. Clean the fingers,ensure good connections as the other wire connector spade for the other contact finger is probably compromised. You might de-oxidize the plate by soaking in pure white ammonia.At any rate,I agree about the quality of the machines and you might be faced with a small parts order from eco-quest.Do include the plate, a bulb and the bulb starter. I run 5 of these in a commercial setting and they are fairly enjoyable to work on.

Jul 25, 2009 | Ecoquest Fresh Air Living Air Purifier

2 Answers

The ozone generator quit working. What is the problem and where can I get parts ?


You can pull off the rear filter, pull the ozone plates, defeat the safety interlock, turn the unit on, and place a screw driver (holding the plastic handle) one one of the ozone bars, and try to make an arc between the screwdriver and the other bar.

If you get an arc, the ozone plates are dirty. Clean well with a brush and sudsy ammonia. If no arc, either the hv transformer is bad, the main circuit board is bad, or the ozone control is bad.

There's one other thing you can check: The two wires that connect to the ozone bars can arc to the chassis sometimes. You can inspect the insulation on those wires to make sure it is intact.

May 12, 2009 | Eagle Advantage Alpine Air Purifiers Eagle...

1 Answer

Air Purification Unit Model ALP-615


Moist air reduces the efficiency of ozone production for this unit. I am not sure what the water thing is about.

Did you try cleaning the glass plate or ceramic plate ozone producing unit with soap free ammonia? Also did you try using a pencil eraser on the contact points on the glass plate? I think the ammonia cleaning and contact points on the glass plate should be your first option. Check your maintenance on the units manual.

Try the manufacturers website for their trouble shooting guide...walks you through most problems and how to fix them.

Apr 22, 2008 | Alpine Air XL-15 Air Purifier

1 Answer

Living Air XL 15, no ozone


My XL-15 had the same problem a few years ago. I had a broken wire on the fan, and the Ozone problem turned out to be a problem with the power supply. I had to send it in to have it repaired.

Mar 18, 2008 | Ecoquest Living Air Classic Air Purifier

Not finding what you are looking for?
Ecoquest Breeze AT Living Air Purifier Logo

Related Topics:

311 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ecoquest Air Purifiers Experts

fordexpert

Level 3 Expert

5501 Answers

Michael Youngman
Michael Youngman

Level 2 Expert

156 Answers

The Knight
The Knight

Level 3 Expert

74136 Answers