Anonymous Posted on Aug 10, 2014

How do i troubleshoot lg lw 8013er window unit

Not blowing hard enough and not cold enough

1 Answer

william simpson

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Genius:

An expert who has answered 1,000 questions.

  • LG Master 1,363 Answers
  • Posted on Aug 08, 2015
william simpson
LG Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Genius:

An expert who has answered 1,000 questions.

Joined: Jan 17, 2012
Answers
1363
Questions
14
Helped
318100
Points
1636

Remove filter and see if coil froze up. that will slow down air flow.

2 Related Answers

Anonymous

  • 415 Answers
  • Posted on May 14, 2010

SOURCE: one of my ductless a/c units is not blowing cold

Check to see if all of the outside condensing units are running. Identify the one that is part of the "problem" system. Is it running? What is different about that one than the others? Let us know and we will dig deeper into helping you troubleshoot.
If it is not running, check for any tripped circuit breakers or blown fuses to the outdoor unit.
Let us know.

I hope you find this information to be very helpful to you as a jumping off point, moving forward.
Please leave a rating. :-)

Ad

Anonymous

  • 43501 Answers
  • Posted on Sep 22, 2011

SOURCE: My air conditioning unit just

Hi,

Here is a tip about troubleshooting your air conditioner...
There are many things that can cause your air conditioner not to cool...

AirConditioner Trouble - Review the Possibilities

heatman101

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
1answer
0helpful
1answer

The if good doesn't get cold enough

blow out coils
dust may be built up on them
I take it you tried defrosting the unit
your question is hard to understand
0helpful
1answer

My new ac unit isnt blowing out cold enough

What's the temp been out side? If its over 95 degrees only expect you air to blow at about 75. It's an air conditioner not a cold air maker.
0helpful
1answer

LG LP0711WNR blows cold air for a few minutes, then starts blowing warm air. It will start blowing cold air again if I wait several minutes. Or if I turn it off and wait a few minutes it will blow c

I just experienced this problem myself. What helped me was cleaning out the lint trap. My guess is that the until sucks in air through there, then conditions it. Blows the cold air out the top, and hot air out the tube. When it can't suck a decent amount of air in, the condenser can only condense so much of that limited amount of air. When it runs out, the unit just runs the fan until enough air has been condensed.

My lint trap was filthy, hadnt Bern cleaned in years. Soon as I popped it off, the unit started belching out cold air nonstop. Clean your lint traps! Don't make my mistake!
0helpful
2answers

Lg lwhd1009r

Most window air conditioners run the fan all the time but cycle on and off the compressor that makes it blow cold air, I knew a AC that was a small Hunter Bay brand (which I think is LG) that shut fan off also when it reached the right temperature.

Hard to test them in winter, you may not have it warm enough in the room for it to start making cold air, generally speaking that could be the problem.
0helpful
1answer

My air conditioning unit just stopped blowing cold air today. It is a window unit, i'm not sure of the model number, but it is an LG.

Hi,

Here is a tip about troubleshooting your air conditioner...
There are many things that can cause your air conditioner not to cool...

AirConditioner Trouble - Review the Possibilities

heatman101
0helpful
1answer

Why does our LG air conditioning unit leaks? It's inside our room and the dripping water is damaging our wooden floor.. Please help.. thanks!

The drain is stopped up or the unit is not tilted back enough to drain out the back. If the drain is stopped up sometimes you can blow it out with compressed air from the bottom of the front coil. If the unit is not tilted enough in the wall or window it cannot drain out of the proper drain hole in the back of the unit. Hope this helps you.
6helpful
2answers

Ge refrigerator not cold enough

Check freezer... for Frost build up and if Fan is blowing, Check condenser... To make sure clean, and the fan is blowing by compressor, Check Recirclating Vents in refrigerator... to make sure theres no blockage, CONTROLS ...should be in the middle setting,
Not finding what you are looking for?

105 views

Ask a Question

Usually answered in minutes!

Top LG Heating & Cooling Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

MattS1978

Level 1 Expert

7 Answers

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

Are you a LG Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...