Question about Heating & Cooling

1 Answer

Fan is working on inside unit and also on compresser unit outside, but compresser does not produce cold air. The air conditioner is an Airforce easy fix 12000 btu pack.

Posted by on

Ad

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 5 Answers

You are most likly short or out of refrigerent which mean you have a leak somewhere find a refirgeration mechanic.. if need be fill it with nitro to find the leak

Posted on Jun 30, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Fan on unit comes on but no cold air comes from the registers


is the outside compressor running or just the condensor fan.

Jun 18, 2014 | Goodman Heating & Cooling

1 Answer

The AC unit turns on and I can cycle through the options in order to adjust the fan speed however the fan does not start in any of the three settings. The ac unit produces cold air, however the fan does...


You say the unit produces cold air ??? where are you getting the cold air from???
If your fan does not run in any speed F1, F2 F3. and a funny smell sounds like the motor is bad
Mine works in F2, F3 but not in F1

Apr 12, 2011 | Kenmore 75085 Air Conditioner

1 Answer

Is the fan on the outside unit supposed to turn when the heat is on or only for the air conditioner? Our unit is omitting a strange odor and the fan will not move even if we switch the unit to air...


The outside fan is used when ever the compresser needs to be cooled. So depending upon the outside temp as well as the temp of the refrigeration, it may not come on. When you say "our unit is ommiting a strange odor" are you refering to the outside condenser? or from the air handler? and what does it smell like? Please give us more to work with to be able to help you. Yes there are people looking and working on problems here at Fixya.com.

Jan 22, 2011 | Ruud UAKA042 Air Conditioner

1 Answer

Inside fan turns on when outside unit is in defrost mode when heat is selected. This causes it to blow cold air for about 10 to 15 minutes prior to the outside fan starting.


The inside fan will run while the unit is in defrost. The electric heat strips should kick on to help prevent you from feeling this cold air. When the unit is in defrost it is essentially running in the A/C mode. You should make sure the electric heat elements are working then go from there.

Dec 11, 2010 | Goodman PHKJ048-1 Air Conditioner

1 Answer

My outside a/c condensing unit's fan runs, but inside vent air is not cold. compresser may not be running. inside vent air was cold last week. Janitrol ckj361ab is model # of outside unit.


Start the unit and go outside to see if the insulated pipe is sweating or cold, hot air should be discharging from top of outside unit. Since the breaker is not tripping, my best guess is the compressor is not operating. You might have to replace the capacitor.

If you can hear the compressor operating, then most
likely needs refrigerant

Jun 17, 2010 | Heating & Cooling

1 Answer

Goodman cpl-j42-1a a/c unit, fan on outside unit not working, inside there is cool (not cold) coming out of vent..


sounds like you have a bad fan motor in outdoor unit or a bad run capacitor ck cap first you can go 1 size larger than listed on motor data plate

Jun 10, 2010 | Goodman CKL42AR42 Air Conditioner

2 Answers

I noticed some straining noise coming from my a/c unit today. The fan on top of the condenser runs fine but as soon as the compressor tries to kick on the fan stops for a split second and you get a kind of...


You amy ahave a bvad capacitor on the outside unit. It starts the fan and the compressor. You can change this yourself. Open the outside panel and you will see a silver canister with terminals out the top. Replace this and I think your problem will go away. On the cap. it will say something like 30uf 5uf 370 ot 440 Just get these numbers and get a new one. Russ

Aug 14, 2009 | Goodman CKL24AR24 Air Conditioner

2 Answers

My outside unit is not actually working. It is


Hey, there. So, you have a hum outside, is your fan motor running outside? Does the compressor run and stay on, it is louder than the fan motor. The two pipes coming from the unit, the small one should be warm, the big one should be cold. Let me know what you got

Jun 20, 2009 | Ruud Matching Split Air Conditioner

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

210 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

2598 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...