1 Answer

My old trane air conditioner

My fan does not spin can you help me figure out why. It makes a noise like it will spin but it doesn't

Posted by on

  • getyasum2003 Jun 29, 2009

    thanks how do I know it is just not the fan motor that is bad



×

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    President:

    An expert whose answer got voted for 500 times.

  • Master
  • 3,433 Answers

Sounds like either a relay or start capacitor has failed, Sorry, but, this is a problem only a tech should approach. For safety reasons.

Posted on Jun 29, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Trane XR80 Heater/Air Conditioner, makes a loud banging nose when the fan turns on


If there is nothing hitting the fan, you may have a bearing that's worn out.

Feb 04, 2015 | Heating & Cooling

1 Answer

Trane xe 900 compressor operates and blower motor stops


You need new compressor (doesn't worth to repair old one). Take a look on amazon: Amazon com Trane air conditioner compressor. I hope this was helpful. cheers

Mar 16, 2013 | Heating & Cooling

2 Answers

Old 30 + year old trane. Fan in front. Coils in back. Should the fan be spinning clockwise or counte? I assume it blows air out the front, pulling air pass the coils. Also have to push fan to start. Assume...


It should pull through the coil and blow out the front. The best way to find out is look at the coil. Is there dirt on the inside of the coil or the outside? If there is dirt on the inside, it tells you its been blowing through the coil. If there is dirt outside the coil it tells you its been pulling through the coil. Generally, pulling through the coil gives more square inches of air passage across the coil. Hope this helps.

Sep 13, 2011 | Heating & Cooling

1 Answer

I have a trane XB1000 unit (DOB around 2000). Was cooling fine, but noted a whining noise at the outside unit. Loudest near the base below compressor tank. Interior filter clean, a-coil fairly clean,...


If the sound is coming from the outdoor unit, check fan blade if unbalance and if the compressor is making the noise, an internal mounting spring must be broken, be ready to replace the compressor when the internal pipe got broken.

Sep 03, 2011 | Heating & Cooling

1 Answer

My outside unit fan doesn't spin. i hear a clicking noise and a humming but the fan won't spin. i've tried to spin the fan and it spins freely by hand.


You may need a new start capacitor or fan motor.I would have the capacitor checked by a electrician and changed if needed. Good luck and thank you.

May 31, 2011 | Ruud UAMB Air Conditioner

1 Answer

Why is my fan motor on my trane air conditioner running backwards when we turn the unit on. It is a trane a053bs.


Check the capacitor for the fan. Has the fan been replaced recently? If so make sure the start lead is connected to the capacitor.

Jun 19, 2010 | Goodman CKL24AR24 Air Conditioner

1 Answer

Trane XE1200 Fan Motor


Most likely problem with a not-so-old motor is the run capacitor for the fan.

Some units have fan & compressor capacitor combined into one -- others are separate.

The capacitor can be tested with a multi-meter with an MFD setting -- it should read reasonably close to the specs marked on the capacitor.

Charlie

Aug 19, 2009 | Heating & Cooling

1 Answer

Trane XE 1200 ac The outside fan stopped


unless you have a meter youneed to see if the unit is asking the fan to turn on. if so the fan (which i doubt) maybe gone bad or the starting capasitor for the fan... is there anyway of checking the voltage to the fan

Jun 22, 2009 | Heating & Cooling

2 Answers

Fan Not Working


either bad condenser fan motor or fan capacitor

Apr 24, 2009 | Samsung AW0503B Air Conditioner

Not finding what you are looking for?
Ruud Central System Air Conditioner Logo

Related Topics:

288 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ruud Heating & Cooling Experts

Donni Steen

Level 3 Expert

659 Answers

Bill Long

Level 3 Expert

587 Answers

Tim Whalen

Level 3 Expert

3074 Answers

Are you a Ruud Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...