Question about Hayward H Series Induced Draft Abg 100,000 Heater

1 Answer

HAYWARD POOL HEATER FIRES FOR 5 MIN. THEN GOES OUT

THE POOL HEATER FIRES THEN GOES OUT AFTER 5 MIN. THE FAN KEEPS RUNNING BUT SEEMS TO GO INTO THE SLOWER SPEED. I CLEANED THE BURNER AND CHECKED THE WIRING CONNECTIONS. FILTER PRESSURE IS FINE.AFTER ABOUT 1 HOUR I CAN FIRE IT UP AND THE SAME THING HAPPENS.

Posted by on

Ad

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Corporal:

    An expert that hasĀ over 10 points.

    Mayor:

    An expert whose answer gotĀ voted for 2 times.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 9 Answers

Sounds like it is cycling on high limit; causes are related to water flow through the heat exchanger or a faulty high limit(doubtful given the heater cycles back on). Check the internal bypass for obstructions; has anyone worked on it recently? There are usually two high limit switches with different trip temperatures; installing the wrong one could also be the culprit. Does the heater "bang" before it goes off (a sign that the water is boiling inside the tube bundle)?





Posted on Jun 28, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Cant change pool heater temperature


see if set on remote if not bad display board or hold up and down at same time for 7 seconds maybe locked

May 21, 2013 | Hayward Pool & Spa

1 Answer

Pool heater Hayward H100IDP1 power to gas valve problem


possible gas valve if when quits is there gas pressure if ok make sure not overheating check manual bypass valve

Sep 01, 2012 | Hayward 100kbtu Pool Or Spa Propane Gas...

Not finding what you are looking for?
Hayward H Series Induced Draft Abg 100,000 Heater Logo

941 people viewed this question

Ask a Question

Usually answered in minutes!

Top Hayward Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1383 Answers

Craig Butler
Craig Butler

Level 3 Expert

1723 Answers

Charles T Nevin
Charles T Nevin

Level 3 Expert

4070 Answers

Are you a Hayward Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...