When i turn on the power switch the electricity does not flow to the circuit and it cause no sound and picture....

Posted by on


1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points


    An expert who has answered 20 questions.


    An expert that has over 10 points.


    An expert whose answer got voted for 2 times.

  • Expert
  • 129 Answers

Good day.
Try to check if the fuse of your tv is busted. Also, try to look for any burnt parts.


Posted on Mar 29, 2008


1 Suggested Answer

  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

A 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
The service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Good luck!

Posted on Jan 02, 2017


Add Your Answer

Uploading: 0%


Complete. Click "Add" to insert your video. Add



Related Questions:

2 Answers

I have a 2001 crown Vic 4.6 L 13.6 volt battery but no power turn key no clicks or fuel pump check every fuse in the car and can't get any electrical works light,wipers, alarm etc what is the problem

I suggest you go to youtube an check out some videos on basic automotive electrical trouble shooting , how to read wiring diagrams go to . for free wring diagrams .An check out power distribution diagrams ,get yourself a DVOM - digital volt ohm meter an test the electrical circuits .That's the only way your going to find an fix the problem . Could be the ignition switch , blown fusible link . do you know what a fusible link is ? There not in fuse boxes , there inline in wiring . Automotive Electrical troubleshooting Using Wiring schematics part 1

Feb 11, 2016 | Cars & Trucks

2 Answers

My sharp aquos lc-42d63x keeps turning of and on

Fault with main board. Contact any service technician; or the authorized service center. If you wish to get some details; check the site linked here. Surf the site with patience. Pull up older posts.

Aug 12, 2014 | Sharp Aquos LC-42D62U 42 in. LCD HDTV

1 Answer

I have a older York Split unit system. My compressor and fan will not always start..and today it just buzzes for a moment then stops. Does this sound like a sensor? It flashes red twice on the outdoor...

Sounds like the contactor may be pitted or could even have bugs or ants in it. The contactor is the automatic switch located in the outdoor unit. The power coming in to the unit will be tied in to this switch. This switch is operated by the thermostat and has contacts that make the circuit when the thermostat come on. Sometimes these contact will pit and be worn out causing the electricity not to flow to the air cond. Other times ants like to crawl up in to these contacts and cause the electricity not to flow to the unit. A contactor is not expensive, but if you take yours off to get a new one, take a picture of it before you unwire it and even make a schematic so you will know where to put the wires back. Hope this helps.

Jul 11, 2011 | Heating & Cooling

1 Answer

Copier displays H4 error code and would not copy

detail for error code H4: Fusing section low temperature trouble
•The set temperature is not reached within the specified time (normally 3 min) when warming up or resetting from pre-heating. Cause:
  1. Cause thermistor trouble
  2. Heater lamp trouble
  3. Control PWB trouble
  4. Thermostat trouble
  5. AC power trouble
  6. Interlock switch trouble
  • If the heater lamp blinks normally:
  1. Check the thermistor and its harness.
  2. Check the thermistor input circuit in the
  3. control PWB.
  • If the heater lamp does not light:
  1. Check for heater lamp disconnection and
  2. thermostat disconnection.
  3. Check the interlock switch.
  4. Check the AC PWB and the lamp control
  5. circuit in the control PWB.
good luck

Oct 13, 2010 | Sharp AL-1457 Black and White Copier

1 Answer

Power windows wont work what fuses can i check i have replaces the driverside switch.

Fuses, Switches, Circuit Breakers And Relays
Check under hood and under the dash driver's side.
There may be a sticker on the inside of the panel cover that tells you the legend. Otherwise, it requires testing each and every one of those fuses, preferably with a fuse tester that can do it more expediently than pulling each one out and looking for a broken conductor.

Most vehicles use one or more fuse panels. This one is located on the driver’s side kick panel tcca6p01.jpg

It is possible for large surges of current to pass through the electrical system of your vehicle. If this surge of current were to reach the load in the circuit, this surge could burn it out or cause severe damage to the vehicle’s electrical system. It can overload the wiring, causing the harness to get hot and melt the insulation. To protect vehicle wiring, fuses, circuit breakers and/or fusible links are typically installed into the power supply wires throughout the electrical system. These items are nothing more than a built-in weak spot in the system. When an excessive amount of current flows through a circuit it causes an increase in heat throughout the wiring. Fuses and circuit breakers are designed as the weak link in the system and will disconnect the circuit to prevent damage to the components contained within that circuit. Components are equipped with connectors so they may be replaced in situations where they were damaged due to a power surge.
The following are descriptions as to how fuses and circuit breakers protect the electrical system:
  • Fuse- A fuse is a weak link in the system designed to create an open circuit when the amperage flowing through that circuit exceeds the limits of the fuse. As the amperage increases, the conductor within the fuse heats up and eventually melts and breaks apart. This open circuit interrupts the flow of current and protects the components in the circuit.
  • Circuit Breaker- A circuit breaker is a "self-repairing" fuse. It will open the circuit in the same fashion as a fuse. The surge creates heat the same way that a fuse is affected. When the surge subsides and the circuit cools down, the circuit breaker will reset and allow current to flow through the circuit. Typically circuit breakers do not need to be replaced.
  • Fusible Link- A fusible link (fuse link or main link) is a short length of special, high temperature insulated wire that acts as a fuse. When an excessive electrical current passes through a fusible link, the thin gauge wire inside the link melts, creating an open to protect the circuit. To repair the circuit, the link must be replaced. Some newer type fusible links are housed in plug-in modules, which are simply replaced like a fuse, while older type fusible links must be cut and spliced if they melt
Always replace fuses, circuit breakers and fusible links with identically rated components. Under no circumstances should a protection device of higher or lower amperage rating be substituted.
Switches Switches are used in electrical circuits to control current flow. The most common use of relays and switches is to open and close circuits between the battery and various electrical loads in a circuit. loads are rated according to the amount of amperage they can handle. All of the current that the controlled load uses flows through a switch. Using a switch with an amperage rating lower than what the circuit is rated for could overload and cause damage to the components located on that circuit. Relays
The underhood fuse and relay panel contains fuses, relays, flashers and fusible links tcca6p02.jpg

Relays are used to control high-current loads with lower currents. Since these some loads require a large amount of current, the thickness of the wire in the circuit is also greater. If a switch were used to control the circuit, all of the current required to power the high-current load would have to pass through the switch. From a design standpoint, relays are used to limit current through switches and reduce the amount of heavy gauge wiring in the vehicle.
Relays are constructed of a set of switch contacts and a small electro-magnetic coil. When current flow through the coil a magnetic field is created. This field causes the contacts to touch, in turn completing the high-current circuit. Typically, relays are constructed so that the secondary contacts are open when the relay is de-energized (turned off). Circuits where relays are used include, but are not limited to, the horns, headlights, starter motor, electric fuel pump, blower motor and cooling fan motor.
Relays are composed of a coil and a set of switch contacts. The large wires connect a high current power source to one side of the relay switch contacts and from the other side of the relay switch contacts to the load. The smaller wires connect a low current power source to the relay control coil and from the control coil to the control switch and then to ground. tcca6g02.gif

Load Every electrical circuit must include a "load'' (something to consume voltage from the power source). Loads are resistances included in circuits to limit current flow. Loads are the components installed in circuits, such as headlights, wiper motors, door lock solenoids. Without a load, the battery would flow all of its energy through a circuit directly to ground. This is called a "dead-short to ground". The unchecked flow of electricity would cause a great amount of damage to the circuit by developing a tremendous amount of heat. Short circuits can develop sufficient heat to melt the insulation of surrounding wires, even reducing a multiple wire cable to a lump of plastic and copper.

Jul 26, 2010 | 2001 Ford Taurus

1 Answer

Sharp 2DR-S100S Ticking sound, will not turn on

does it tick all the time are just a few minutes and can you turn it off and back real qiuck and see or hear high voltage come on are see a flash is sounds like you have what is know as startup are shutdown circuit trouble

Feb 22, 2009 | Sharp 25R-S100 25" TV

2 Answers

Replaced fuel pump in 1998 for ranger

Diagnostic Trouble Code (DTC) P0232 indicates that the powertrain control module (PCM) detected the FPM circuit voltage was high when the fuel pump was commanded off. The FPM circuit is wired to a pull-up voltage inside the PCM. The FPM circuit will go high if, with the key on and the fuel pump commanded off, the FPM/FP PWR circuit loses its path to ground through the fuel pump. The FPM circuit will also be high if the FPM/FP PWR circuit is shorted to power.
Possible causes:
No Start:
Inertia fuel shutoff (IFS) switch not reset or electrically open.
Open circuit between the fuel pump and FPM circuit connection to the FP PWR circuit.
Poor fuel pump ground.
Fuel pump electrically open.
Diagnostic Trouble Code (DTC) P0102 indicates the MAF sensor signal went below 0.39 volt (refer to Voltage to Mass Air Flow Conversion Table at beginning of this Pinpoint Test) sometime during normal engine operation (Continuous) or during Key On Engine Running (KOER) Self-Test.
Did you have the MAF unplugged?

Feb 18, 2009 | 1998 Ford Ranger SuperCab

1 Answer

Sharp aqous lc 37 in tv power no picture,sound

Your control board seem's defective or the inverter board (associated circuits) are bad. This is common in most TFT-LCD Tv's.......

Nov 30, 2008 | Sharp Aquos LC-37GD6U 37 in. LCD HDTV

2 Answers

No picture

Hello shun09,
This problem denotes a possible shutdown circuit activation caused by excessive current flow from the IHVT. This might be caused by a shorted horizontal output transistor, or a shorted and or open transformer (Applies to CRT type TV). This also can denote a switching power supply shutdown circuit problem (Applies to LCD or Plasma TV). Both of these issues should be checked by a qualified TV technician.
Thank you,
I hope this helps, Shuttle83 

Jul 08, 2008 | Televison & Video

1 Answer

Trouble in sharp t.v.

Check horiz output transistor and solder any / all bad connects,
Check fuses.......T.

Nov 06, 2007 | Sharp 25N-M100 25" TV

Not finding what you are looking for?
Sharp 32C-240 32" TV Logo

Related Topics:

64 people viewed this question

Ask a Question

Usually answered in minutes!

Top Sharp Televison & Video Experts

The Knight
The Knight

Level 3 Expert

75025 Answers

Donald DCruz
Donald DCruz

Level 3 Expert

17130 Answers

Jaime Hernandez

Level 3 Expert

2326 Answers

Are you a Sharp Televison and Video Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides