My central ac unit never shuts off, the fan blows all the time (the compressor comes on and cools good, but the fan never stops running)is this normal?

Posted by on

  • Robotinner May 11, 2010

    Inside Fan? or outside?

  • thetim May 11, 2010

    the inside fan or out side? On the t-stat is it set fan-on?

×

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Expert
  • 296 Answers

No..check the fan relay/board

Posted on Feb 17, 2010

2 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 233 Answers

SOURCE: whirlpool central ac stopped blowing air, cool or

If you are refering to the indoor fan that is not running, but that the outdoor condenser is operating, the next place to check is the circuit board in the air handler, this is the control for the fan motor. the relay may be bad that actuates the fan circuit. if the relay is bad there will be no power to the fan motor. If you have power to the fan motor then the motor is bad and the motor and capacitor should be replaced.

Posted on Jul 20, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

2002 4 ton Bryant air conditioner shuts off, fan still runs but not cooling is problem in the controls in the attic or in the AC unit or both?


With a non heat pump it is a simple 24 volt AC control circuit. In the attic there is a relay that is actuated via the fan control wire directly from the thermostat. On the thermostat there is an auto/man switch that controls the fan. Manual the fan runs all the time. Auto fan turns on and off with the outside compressor.

If the system is not calling for cool and the fan continues to run the fan relay is sticking. common problem. Sometimes after running for several days the relay will stop sticking if not, replace relay.

If the system is calling for cool and the compressor stops I would still expect the fan to run until thermostat tells the A/C to off. Some compressor units include a safety switch or high-pressure cut-out switch A blocked internal valve bad control board or external fan in outside unit defective no air flow in outside unit.
High pressure cut out not good,

Suggest turning temp max cool and observe. If acceptable cool and the compressor runs without interruption all is good, except for the blower in the attic. Safely check relay in attic blower circuit.

Hope this helps.

thermostat-heat-cool-fan-on-czwsw2ci0layswcsyy3dj4dr-4-2.jpg

basic-thermostat-wiring-diagram-czwsw2ci0layswcsyy3dj4dr-4-5.jpg

Jun 28, 2017 | Bryant Heating & Cooling

1 Answer

Unit stopped cooling, inside unit runs, outside unit does not


could be a gas leak ( low gas pressure shut off switch, failed start run capacitor for the compressor , vermin problem shorting out the power board outside
The inside unit is just a fan
call an accredited ac technician to get a proper diagnosis and quote

Aug 06, 2016 | Heating & Cooling

1 Answer

Condenser Fan Shuts off after 15-20min, Compressor continues to run but gets hot


Condenser fan motor or motor wiring is bad. That compressor should never run without the fan. Good luck.

Jun 14, 2014 | Beverage-Air MT27 Beverage Cooler...

1 Answer

Ac unit runs, inside blower shuts off after 2 mins, compressor continues to run, t-stat still calling for cool


My central AC unit decided to stop on the hottest day of the year. It would start and run normally for a few minutes and then the blower would shut off. After checking the breakers, thermostat and overflow shut off (did not have one) I saw something about a blower motor capacitor. This was easy to get to and replace and my last hope before waiting for someone to come fix it. The capacitor cost $4.04 with tax and had my AC working again. Needless to say I was beyond happy. I hope this can help others with a similar problem.

May 20, 2012 | Heating & Cooling

1 Answer

I have a ac central unit that has freon put in it, but it still blows out hot air inside the house.


Need a bit more info. Do you hear the compressor come on? Is your Tstat in the cooling mode? Shut it down for a minute and turn it back on. you should hear the indoor fan come on . outside fan come on and the compressor come on the sametime as the out door fan comes on.. Freon is just a gas that is used to exchange heat .

Jun 26, 2011 | Heating & Cooling

1 Answer

My ac comes on in my RV and runs for a about 15 minutes and then the fan shuts off and finally the compressor shuts off. this happens before reaching the cooling temp. When it comes back on the fan does...


The Fan topside , Is the one working? The one that blows on the condensor? If not, your compressor can be trying to start against high head pressure. Ck the other fan, not the one that blows inside, the other one.It cools down the condensor and if the pressure is too high it will hinder the compressor. Good Luck

Sep 12, 2009 | Heating & Cooling

1 Answer

Hello, I have a Kenmore 580.75124500 ac/heater


It is probably the compressor. You will need to check if the compressor is being called to come on. Do you hear the compressor running? If you do, I would remove the unit from the wall or window, and wash it down real good with a hose being careful not to get the electronics wet. If not and the unit sound different than it did before, it's probably time to buy a new one.

Mar 31, 2009 | Frigidaire FAC125P1A Window Air...

4 Answers

Central ac blowing hot air outside fan not moving but making a noise


This is nothing but an either or -or ! First, make the thermostat calls for cool, there are suppose to be 2- noise outside, the fan motor and the compressor (and if a old system,a humming noise which is the contactor coil which picks up the main 240-volts).. hurry up and take a stick or something and turn the fan blades, if it picks up speed and run, then its the capicator. If not then the fan motor is bad.! (BOTTOM LINE)!

Jun 09, 2008 | Heating & Cooling

2 Answers

Thermostat ?


The Air conditioner are good only the adjustment of thermostat are the problem, select the thermostat in lower #3 you observe the thermostat will off in such time temperature reach to #3 If you full adjustment the compressor will not off.
In fan selector the compressor will autamatic off because no connection attached fan only .

Jan 05, 2008 | Kenmore 73089 Air Conditioner

Not finding what you are looking for?
Whirlpool ACQ122XK Air Conditioner Logo

Related Topics:

810 people viewed this question

Ask a Question

Usually answered in minutes!

Top Whirlpool Heating & Cooling Experts

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Bill Long

Level 3 Expert

587 Answers

Tim Whalen

Level 3 Expert

3074 Answers

Are you a Whirlpool Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...