Question about Water Heaters

1 Answer

My GE gas fired water heater pilot goes out after 10- 15 minutes. Water heater was manufactured in 2005

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Expert
  • 332 Answers

You will need to change the thermal coupling,, when it is lit look at it and make sure there is no water dripping down on it, but for now it just sounds like the thermocoupling

Posted on Jun 27, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

New thermocouple on GE/rheem water heater pilot still won't lite


does the pilot go out when you let off the button? Or does the pilot not light at all?

If you dont get any gas at all to the pilot the the gas valve is bad.
Of you get a pilot light that goes out when you let go of the button then the therno couple is not reading the flame (needs adjustment so the pilot flame touches it)
did you kink the new thermocouple? or over tighten it at the gas valve.
if it was kinked its now toast,cant straighten them. If kinked and starightened the fluid inside has broken the inner seal and wont work.

Jan 10, 2013 | GE 50 gal. Heat Pump Electric Water Heater

1 Answer

Water heater goes out


The burner needs to be adjusted

Mar 13, 2017 | Water Heaters

1 Answer

Gas water heater: burner doesn't fire, replaced gas control valve


Hello,Don't worry about the rust flakes as every burner collects then and is normal.The new control should click.Please check incoming gas pressure supply 3.5"WC natural gas / 9"WC for LP.Check it at the piolt tube with a pressure dial meter,I assume the water temp now is cold.Did you change the thermocouple also as this provides the power to run the control?

Apr 22, 2010 | General Electric GE SmartWater Household...

1 Answer

We dont think our cylinder is on we have just moved in and have no hot water


The question is? I'll assume you cylinder is the water heater, right?
On the heater (water) you will find or see the red controls and a sheet metal cover over a hole. Remove the cover and this is where you light the pilot light. Press down on the red dial and turn it to pilot. In that position you will be able to press the red button . Geyt a long match or bbq lighter, then, holding down the red button dow for a minute or so and place a match or lighter into yhe area where the lines go The flame will catch the gas and lite the pilot if yo simply move your glame around. When the flame catch on the pilot, continue holding the button down for sveral minutes until the buld the flame isheating gets hot. Then release the buton and turn the main dial to on. The main burner should fire up. If not, and the pilot goes out, repeat the process. The bulb in the pilot flame is a thermocoupler that shuts all gas off if it doesn't detect a pilot flame, so hold the button down longer. If the pilot goes out when you release the button, The thermocoupler is no good and needs replacing. Good Luck_Ned_

Oct 31, 2009 | Rheem 80 GAL ELEC TALL Water Heater 6YR SC...

1 Answer

This is a new whirlpool hot water heater.Pilot lights, burner fires, water heats up to temp. burner and pilot both shut down. Unit has to be started manually each time


LP OR NAT GAS , IF IT IS LP CHECK GAS PRESSURE @ TANK AND MAKE SURE NOT TO HIGH , IF NAT STILL COULD BE THE PROBLEM HAVE THE GAS COMPANY CK PRESSURE

Feb 22, 2009 | General Electric GE SmartWater Household...

Not finding what you are looking for?
Water Heaters Logo

Related Topics:

267 people viewed this question

Ask a Question

Usually answered in minutes!

Top Water Heaters Experts

Donni Steen

Level 3 Expert

659 Answers

Brad Brown

Level 3 Expert

15557 Answers

Gil Shultz

Level 3 Expert

3368 Answers

Are you a Water Heater Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...