Pilot will not stay lit after button release

I have a Hayward H250 series pool heater. After lighting the pilot light and waiting one minute while pushing the pilot control button down, when I release the button to put it in the on position, the pilot light goes out. It will not stay lit. What is the problem

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Expert
  • 139 Answers

Most likely you have a thermopile that has low output. it takes about 100mv to maintain pilot light

Posted on Jun 25, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

H250 hayward pilot series


Those particular heaters can be tricky because they came a few different ways, including a millivolt to electronic spark conversion that was done on site.
Your best bet is to get an old pool tech out there to see if they can get it fired up. The variables involved are far too extensive to troubleshoot in this format. Good luck with it.

Jul 02, 2013 | Hayward H Series Electronic Ignition...

1 Answer

Pilot won't stay on


Burners don't have anything to do with the problem of pilot not lighting. Is the problem that flame will not 'stay' lit? Or you can't even get a flame to ignite? If former: possible bad pilot generator or bad gas valve. If latter, possible bad gas valve or no fuel to ignite.

Dec 23, 2012 | Hayward H Series Pool & Spa Heater 400k...

1 Answer

I have an H250 NG and when I light the pilot it goes out when I release the pilot button on the gas valve?


The first thing That comes to mind is a bad pilot generator or thermopile. This makes a small half volt charge that energizes the magnets that open the two stages in the gas valve. Next would be a bad gas valve itself. You will need a milivolt meter to check both of these. Lastley is the safty circut. This is the string of switches that can shut the heater down if problems exist. Their are two sets of wires connected to the gas valve. One set goes down to the pilot, this is for the pilot generator. The other set is the safty circut. If you remove these wires and the pilot lightes and stays lit the problem is in the circut. Still no pilot then it is in the pilot or valve. Good luck.

May 28, 2010 | Hayward 250kbtu Ng Pool Heater - Inground

1 Answer

Hi I have an Hayward H Series pool heater and the pilot doesn't stay lit when I depress the control to turn it on. Any quick solution for that ?


Check the thermocouple that the pilot light heats up. If it is not working then the gas to the pilot will not stay on.

Jul 01, 2009 | Hayward H Series Pool & Spa Heater 400k...

1 Answer

Pilot light is lit, but heater will not fire


Make sure thermostat is set higher than water temperature. Make sure pump is running and water is flowing through unit. If gas valve is not opening then flame sensor or gas valve is bad.

Jun 02, 2009 | Hayward 250kbtu Ng Pool Heater - Inground

1 Answer

Hayward H250 (millivolt) pilot won't stay lit


make sure the flame hits the thermo couple if so then replace it lows has them in the water heater section thermo couple gets hot makes millivolt signal then opens gas valve

May 08, 2009 | Hayward H Series Millivolt 250,000 Btu...

1 Answer

Heater won't stay lit


On your main gas manifold you have orfaces that screw into it at each burner. Remove these and see if their are small spider webs in them. They will look like little lint balls. They can keep your main burner from getting gas and in turn keep the heater from sensing flame. The pilot lights and the heater starts but no flame at the main will shut it rite down. See if this helps.

May 05, 2009 | Hayward H Series Millivolt 250,000 Btu...

Not finding what you are looking for?
Hayward 250kbtu Ng Pool Heater - Inground Logo

1,076 people viewed this question

Ask a Question

Usually answered in minutes!

Top Hayward Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1338 Answers

Bill Jordan

Level 2 Expert

372 Answers

john h

Level 3 Expert

12104 Answers

Are you a Hayward Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...