When EKG is hooked up I can get a heartbeat its just flatlined

Posted by Anonymous on

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad
  • 2712 Answers

SOURCE: EKG question

There is no difference. EKG is the earlier name and is so called because the guy who invented it was German and the spelling was ElectrokKrdiogGam. EKG was decided to be the universal term because ECG (ElectroCardioGram) sounded too similar to EEG (electroencephalogram). They thought calling it EKG would then decrease any confusion.

Posted on Aug 27, 2008

Ad
  • 2712 Answers

SOURCE: EKG supprt

Recently, the USA government approved the first pocket-sized EKG machine, so small that it promises easier, faster heart measurements in ambulances, the emergency room - even a possible heart attack victim's bedroom. This devices are already avaliable on special stores and on the internet and usually reffered to as "handheld EKG machine". The most common one is called "ReadMyHeart".

Posted on Aug 27, 2008

  • 157 Answers

SOURCE: Omron Portable Ecg Ekg accuracy problem

Hello Josh. You will need a EKG simulator. I suggest you contact your local community (junior) college electronics class or a local Bio Medical services in your local hospital. When locating one kindly walk in and ask very nicely with the portable in hand if you my perform a operational test for you on benefit.

Posted on Sep 19, 2008

  • 71 Answers

SOURCE: inconsistant tracings, tracing goes flatline after the first 3 QRS complexes

Most likely you will have expired or cheap electrodes. Even if they stick to the patient there still may not be enough moisture in the electrode to conduct a signal. Either that or some of the lead wires may be damaged. All it takes is one intermittent lead to cause the problem you are asking about. The best thing to do is to start with he electrodes and then try the leads.

Posted on Jun 16, 2009

mark24354
  • 776 Answers

SOURCE: MY CONTEC ECG MACHINE CMS80

The power supply (That converts wall (mains) AC power to DC ) is not making "clean" dc power. The most likely problem is the large filter capacitors are " leaking" currect or dry. The small AC component (ripple) that is not filtered from the transformed dc can look like a heartbeat so there is some protection circuitry in these devices. It may be something else, but the large can filter capacitors are most likely. I always recommend that medical equipment be repaired by trained, insured factory technicians. Too many problems are likely to occur and you don't want to misdiagnose someone or electrocute someone because you are too cheap to get it repaired professionally. On the other hand, if you are in central Africa and using it for an elephant research project, get your soldering iron and replace the parts. -Mark

Posted on Sep 17, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

Our brand new Contec ECG 1200 is tracing way to lightly. Can barely read. The unit is registering full charge. Also is not printing patient data. Help!


I copied this from an old question similar to yours:
Ekg machines print on thermal paper, This means that the impression is made by the print head heating the paper. If the print head is not making contact with the paper, you will get a faint tracing or no tracing at all. This needs to be adjust by a technician. Contec is located in China and we are a dealer. If you need their info or want us to look at it for you (for free) simply give us a call

Discount Cardiology
805-484-9985

Jan 16, 2017 | Contec Medical

1 Answer

How to load paper


How to load paper - Fixya

www.fixya.com > Forum > EKG/ECG Machines
39 mins ago - How to load paper - EKG/ECG Machines question. ... Machines. Open Question ... Aug 30, 2012 ' Schiller Cardiovit At 2 Light Ecg Machine.

Loading paper into the MAC 1200 ecg machine - Fixya

www.fixya.com/.../t4590309-loading_paper_into_mac_1200_ecg_mach...
Apr 19, 2010 - loading paper into the MAC 1200 ecg machine how to load the paperinto the machine? ... Ge Medical Systems Ge Marquette Mac 1200 question.

Contec ECG Monitor & pulse oximeter Ekg printed sheet ...

www.hcuck.com/search/p1207318-contec_ecg.../ekg_printed_sheet
Question about Ge Medical Systems EKG/ECG Machines ... Open the . ... ...ekg-manual The paper is is backwards, there are 4 ways to load paper BUT only 1 ...

Electrocardiograph (EKG / ECG) Questions and Answers


Dec 21, 2015 | Medical

1 Answer

Everytime that i do an EKG it states drop ,I replaced the of clips and it still says drop,what can I do to correct this problem


Either one of these is causing the problem:
Battery is dying, or
malfunction.
replace the battery to see if it works, if not, replace it.

Sep 12, 2015 | CMS Contec ECG80A Single-Channel Handheld...

1 Answer

New Contec ECG 300EG model no tracings appear on the EKG paper.


Ekg machines print on thermal paper, This means that the impression is made by the print head heating the paper. If the print head is not making contact with the paper, you will get a faint tracing or no tracing at all. This needs to be adjust by a technician. Contec is located in China and we are a dealer. If you need their info or want us to look at it for you (for free) simply give us a call

Discount Cardiology
805-484-9985

Aug 18, 2012 | Contec Medical

1 Answer

User's manual for a Contec Pulse Oximeter CMS50


Hi,
Here is a link where you should be able to download the appropriate manual for your product.
http://www.contec-oximeter.com/sdp/499627/4/home-2955239/0/Brochure_Download.html
You did not mention which version of the cms-50 that you own and apparently there are several. But the link includes different versions so you should be able to download what you need.
Hope it helps. Please let me know
Thanks

Apr 22, 2010 | Contec ECG Monitor & pulse oximeter

1 Answer

Inconsistant tracings, tracing goes flatline after the first 3 QRS complexes


Most likely you will have expired or cheap electrodes. Even if they stick to the patient there still may not be enough moisture in the electrode to conduct a signal. Either that or some of the lead wires may be damaged. All it takes is one intermittent lead to cause the problem you are asking about. The best thing to do is to start with he electrodes and then try the leads.

Apr 14, 2009 | Midmark Medical

1 Answer

EKG Problem


EKGs provide useful data and can help detect various problems related to heart function. One basic determination that can be made with an EKG is the heart rate, which can be determined by measuring the distance between peaks. Diagnosis of certain medical problems is also possible. For example, in patients with high blood pressure, the amplitude of the QRS complex is significantly increased. The balance of certain chemicals in the body can also be detected by an EKG, since the amplitude of the signals is related to the levels of chemicals in the body. Damage in the heart can also be observed by a deformation in the Q wave. The most useful characteristic of the EKG is its ability to detect and describe arrhythmias, or abnormal heartbeats. EKG machines known as Holter monitors are for these detections. Finally, EKGs can be used to observe obstructions in the arteries. This is typically done by looking for a depressed segment between the S and T waves.

Aug 27, 2008 | Omron Portable Ecg Ekg Handheld Hcg 801...

Not finding what you are looking for?
Medical Logo

Related Topics:

54 people viewed this question

Ask a Question

Usually answered in minutes!

Top Medical Experts

Electro Med Services...
Electro Med Services...

Level 3 Expert

6694 Answers

Brad Brown

Level 3 Expert

15639 Answers

Rhonda Webster
Rhonda Webster

Level 3 Expert

948 Answers

Are you a Medical Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...