Generac 7550 EXL runs no power have another

Have another generac 7550 EXL runs no power have another working 7550 switched control and voltage regulator boards still no power. the boards out of the one that wasn't working work in the working one... brushes look good and clean.. have not excited yet.. unit was powering my fifth wheel ac, a small fan and rv refrig and suddenly i noticed the fan going half speed and then nothing...has 60 hours on this thing...any other suggestions before exciting

Posted by on

  • Craig Butler
    Craig Butler May 11, 2010

    Could be the voltage regulator. Diodes can fail. Maybe the generator itself too, but more likely to be a bad connection to the rotor from regulator or the reg. itself.

×

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
  • 1 Answer

SOURCE: Honda CRV 2003 Heat/A.C. fan Fault

I lost the link for this thread, Thanks for posting ED. There was some great help on this problem at this site. the fault ended up being a thermal fuse in the fan speed control moduel (black box in the a/c ducting next to the fan) $3 fix!
http://www.hondasuv.com/members/showthread.php?t=24831&page=6

Posted on Jan 29, 2009

Ad
  • 83 Answers

SOURCE: do you excite generator while it is running ?

Yes! The generater must be running. Only apply voltage for one or two seconds when exciting then check for ac voltage with a meter. You can try again if no voltage. Note: if exciting the field does not work your problem may be something else.

Posted on Mar 30, 2009

  • 1 Answer

SOURCE: Cruise control NOT WORKING

Check your rear brake peddle and see if the sensor for the cruise control is out of adjustment. I had the ame problem on my 1990 GL1500.

Posted on May 29, 2009

  • 154 Answers

SOURCE: generac rv altenator wiring

white is neutral black is hot and green is ground

Posted on Jun 14, 2009

  • 23 Answers

SOURCE: passanger window does not go down from driver power window switch

The control switch on the drivers door is bad if the window rolls down using the passenger switch

Posted on Jun 21, 2009

Testimonial: "not bad"

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

I need a rectifier or avr for generac 3500 xl genarator


Ebay and various places including the maker..

  • VOLTAGE-REGULATOR-3000-3500-WATT-GENERATOR-GENERATORS ... www.ebay.com/sch/sis.html?_nkw=VOLTAGE-REGULATOR-3000-3500-WATT... VOLTAGE-REGULATOR-3000-3500-WATT-GENERATOR ... New listing 3500 Watt Generator AVR Automatic ... 3500W Generator AVR Automatic Voltage Rectifier ...
  • 3500 W 3500 Watt Generator AVR Automatic Voltage Regulator ... https://sites.google.com/site/kltthtyz0i04cd/3500-w-3500-watt... Generac Guardian 22kW Standby Generator NG ... Previously Pay for Shop 3500 W 3500 Watt Generator AVR Automatic Voltage Regulator Rectifier 3.5KW Generator AVR ...
  • How to test your Electricity Generator's AVR, Brushes and ... www.youtube.com/watch?v=tC_LrrZcx38
    • BY GENERATOR GURU
    • 9 MIN
    • 454K VIEWS
    2011-10-21 · Video embedded · When your electricity Generator stops producing power, ... How to test your Electricity Generator's AVR, ... Generac iQ: The Quietest Generator ...
  • Generac Power Systems - Home www.generac.com Generac manufactures the widest range of power products in the marketplace including portable, RV, residential, commercial and industrial generators.
  • Generac Guardian Generator Voltage Regulator Rectifier ... www.ebay.com/sch/sis.html?_nkw=Generac+Guardian+Generator+Voltage... Generac Guardian Generator Voltage Regulator Rectifier ... Generac Guardian Generator Voltage Regulator Rectifier ... Generac Guardian Generator Voltage Regulator ...
  • Automatic Voltage Regulator (AVR) for Generators portable.generatorguide.net/avr.html How automatic voltage regulator (AVR) works in portable generators: ... here you can see a reverse engineered Generac regulator that uses SCRs and UJT.
  • Diagnosing A Generator That Has No Power Output. - YouTube Youtube
    • BY THEDIYGUYDOTNET
    • 3 MIN
    • 150K VIEWS
    2012-11-12 · Video embedded · Diagnosing A Generator That Has No Power Output. ... How to test your Electricity Generator's AVR, ... Generac Portable Generator ...
  • GENERATOR Diagram & Parts List for Model 3500xl Generac ... www.searspartsdirect.com > ... > 3500XL GENERAC Generator-Parts GENERATOR Diagram and Parts List for GENERAC Generator-Parts model # 3500XL ... Generator rectifier Part #: ... Generator voltage regulator Part #: ...


  • Jun 28, 2016 | Generac Electrical Supplies

    1 Answer

    My 7550 exl runs to fast


    The generator needs high RPM to produce the right voltage.

    Sep 06, 2014 | Electrical Supplies

    1 Answer

    Generac portable generator over voltage even with new control board and regulator


    is engine running at 3600 to 3700 rpm at full load. most small engines run at this speed.you can buy a small tach on ebay TINY TACH.. you have to know what the engine speed is

    Mar 04, 2013 | Electrical Supplies

    1 Answer

    Need Users manual for Generac 4000 EXL generator


    Hi and welcome to FixYa, I am Kelly
    Below is a list of all the manuals an owner should have:

    For the 4000 EXL Your actual model number is 01645.
    Operators manual:
    http://www.generac-portables.com/document/index.cfm?doc=1645_0EN11CS_LO.pdf

    Wiring Diagram:
    http://www.generac-portables.com/document/index.cfm?doc=1645_0WDS_LO.pdf


    Parts List:
    http://www.generac-portables.com/document/index.cfm?doc=1645_0PARTSLISTCCS_LO.pdf

    Thanks for choosing FixYa,
    Kelly

    May 18, 2011 | Garden

    1 Answer

    Generator was running and quit delivering voltage while running. Turned it off and then restarted and checked voltage with no load. no voltage...no smell...plenty of oil...seems like a breaker8000 exl...#...


    It very well may have been a breaker that opened up permanently.

    But, I bet that the generator was under heavy load for prolonged time, and one / both of the diodes in voltage regulator have opened up. You will have to disassemble the end housing of the alternator to get to these, and then test with multimeter to know for sure.

    Of course, your generator may have an electronic controller, and not use diodes / capacitor at all. Since don't have model #, can't be sure.

    If engine has dropped much under 1800 (4 pole alternator) or 3600 (2 pole alternator) RPMs, then alternator output would tank or be nonexistent.

    Dec 09, 2009 | Generac Electrical Supplies

    1 Answer

    Engine runs great, but no ac power


    its the rotor ,the stater ,voltage regulateor or control board. i fix these everyday.

    Jul 06, 2009 | Generac 100 Amp 120/240-Volt Transfer...

    1 Answer

    No power output from my generac 5000 power plus generator


    It is possible that your voltage regulator is shot but before purchasing the volt regulator try flashing the fields first and make sure the brushes and rings are clean.

    Apr 09, 2009 | Generac 100 Amp 120/240-Volt Transfer...

    1 Answer

    Generac EPS-15 attempts to engage the starter while running


    I work on these everyday. You most likely have a bad rotor or stater if the starter engages while running and no output. The no out put is making the generator think its not running causing it to try and start. If its not that then its the control board or voltage regulator.

    Apr 07, 2009 | Generac 13,000 Watt / 13,000 Watt Home...

    1 Answer

    No voltage output


    It is possible that your voltage regulator is shot but before purchasing the volt regulator try flashing the fields first and make sure the brushes and rings are clean.

    Apr 02, 2009 | Generac 5622 GP Series GP5000 6,250 Watt...

    Not finding what you are looking for?
    Honda 6370C - Parallel Power Kit For  EU3000i Logo

    Related Topics:

    831 people viewed this question

    Ask a Question

    Usually answered in minutes!

    Top Honda Electrical Supplies Experts

    John Trevino

    Level 3 Expert

    1388 Answers

    Donald DCruz
    Donald DCruz

    Level 3 Expert

    17130 Answers

    Doctor PC
    Doctor PC

    Level 3 Expert

    7733 Answers

    Are you a Honda Electrical Supply Expert? Answer questions, earn points and help others

    Answer questions

    Manuals & User Guides

    Loading...