Out door condenser coil temperature too high. Wash the out door coil out with water unit gets stopped up with dirt and this causes the coil to get hotter than normal.

Posted on Jul 02, 2014

5 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 234 Answers

SOURCE: LG error CH 64

What is the model of the unit?

Posted on Apr 07, 2009

hvac1960
  • 2133 Answers

SOURCE: my LG Artcool isn't working

CH61 means Condenser coil temp high due to non cleaning of condenser/over charged gas/non condensable gas.

Clean your condenser coil. If still problem rests, due to non condensable gas also there will be high temp. kHnce remove the gas, flush out the system and vacumize and then do gas charging.

Posted on Dec 10, 2010

  • 89 Answers

SOURCE: I have an error code

Hi, Please open the front panel of the air con and look for the reset button on the electronic board, press it once. the system will initialize, then you will see all the LED lit randomly wait for a second then closed the front panel and test it. thanks

Posted on Apr 24, 2011

  • 127 Answers

SOURCE: The Air Conditioner will not

If you post the make and model number it should be possible to find the manual online.
then you can look up what "CH61" means

Posted on Jun 06, 2011

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Error code ch 61


try cleaning the outdoor unit with a hose pipe. the err code is caused by high pressure on the outdoor unit. please also check if the fan outside runs when the compressor is on, if not the fault is probably caused by the fan or fan capacitor being faulty.hope this is helpful.

Mar 04, 2016 | LG Heating & Cooling

1 Answer

LG air conditioner model number LMN095HVT units keep on flashing with error code CH 46 and with no response at all. How can I fix it? Thanks for your help in advance!


ERROR CH46:
Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace sensor.

Sep 01, 2015 | LG Heating & Cooling

1 Answer

CH-10 error code in LG a/c.Modal-LBUC609RSA5


RAC Product: Compressor discharge sensor fault. Disconnect from PCB measure resistance 237 kOhm at 20°C, 168 kOhm at 30C. Multi Fdx & Multi V text 8

Dec 24, 2014 | LG Heating & Cooling

1 Answer

Lg dehumidifier ch 67 error


Thanks for the post by Posted by Bill L on Jul 14, 2012.
I decided to take a chance and order the new Sensor assembly $20.50 and install it in my LG LD651EBL Dehumidifier which was giving me ch 67 errors. Wala, it worked, the error code is gone and the dehumidifier is now working perfectly! Thanks

Jul 14, 2012 | LG LD651EBL Dehumidifier

2 Answers

LG dehumidifier LD451EGL with error code CH67


After cleaning the filter, i had to unplug the unit to clear the ch 67 error code before the unit would run again.

Apr 16, 2012 | LG Dehumidifiers

1 Answer

LG Artcool about 4 yrs old error code CH 05. no heating or cooling. cheers.


CH 5 on these machines indicates a communications error between the indoor and outdoor units. Generally, it will require a replacement outdoor board assy to repair it. Lookup LG parts on the internet or ring them for your nearest Agent or parts stockist.

Jun 16, 2011 | Heating & Cooling

1 Answer

I have an error code ch 61 on my LG system


Hi, Please open the front panel of the air con and look for the reset button on the electronic board, press it once. the system will initialize, then you will see all the LED lit randomly wait for a second then closed the front panel and test it. thanks

Apr 24, 2011 | LG LS-L1210CL Mini Split Air Conditioner

1 Answer

Hi, I ve got a aircon LSZ244VM4 inverter and fault code is CH 61.Iam out of warranty 1 yr and the unit has already been replaced 1 time when it was in warranty.So what should i do now and what does CH61...


Ch-61.Condenser coil over 65°C. Check coil and filters are clean and free from debris, and airflow is OK. Check system pressures for non-condesables

Clean coil & filter. If non condensable gas, remove gas and flush out the system. Vacuum and recharge.

Jan 01, 2011 | LG Heating & Cooling

3 Answers

Ch 5 error code


ch5 error code, means that there is a
communication error (serial comunication) between the outdoor and the indoor unit.
Only for LG-airconditioners.

Jan 02, 2009 | LG Art Cool LA121HNP Split System Air...

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

266 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2461 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...