Not blowing cold air

The blower works, the compressor is kicking on, but it's only blowing room temp air. There is nothing else wrong with it, seems to sound the same as always. The display works, the buttons work, I can adjust the speed/mode. But no cold air in any mode or speed, I've tried them all. It stopped working the end of last summer and has been off and unplugged for the winter, hooked it up again last week... still not working.

Posted by on

  • Jen Mercer
    Jen Mercer May 08, 2014

    If it needs refrigerant, is that easy to check? Can I buy that somewhere and do it myself? Is it worth the cost to fix it?

×

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Sergeant:

    An expert that hasĀ over 500 points.

    Champion:

    An expert who has answered 200 questions.

  • Expert
  • 205 Answers

Please check the reffrigrant

Posted on May 08, 2014

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
New users get to try the service completely Free afterwhich it costs $6 per call and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
  • 330 Answers

SOURCE: no cold air on a/c

1. check the fan
2. maybe some place leak
3. Do you still have the warranty?

My central AC had the same problem, lost the freon R-22

Posted on Jul 03, 2008

  • 587 Answers

SOURCE: NO COLD AIR

If the fan and compressor are both running and no cold air then you’re low on refrigerant,
Thermostatic expansion valve closed or bad , dirty condenser or the valves are bad in the
compressor.

Posted on Apr 25, 2009

  • 233 Answers

SOURCE: The compressor works it just kicks out after two hours

the way to verify if the thermostat switch is the culprit : is to shut off the power, "jumper" the thermostat> the device at the other end of the bulb you described, and see if it freezes you out... if the compressor kicks off while this switch is jumpered the compressor is the culprit.

Posted on Jul 12, 2009

  • 44 Answers

SOURCE: Room air conditioner is DOA, won't blow cold

it depends on what country you come.e.g.in Jreland, as long as you can prove you bought the item in a particular shop you dont need a receipt.and it should be still under guarantee.you should try this first..it sounds like a faulty thermostat.

Posted on Jul 22, 2009

relaga58
  • 158 Answers

SOURCE: air conditioner not working

have you tried turning off and on power from the plug ?

Posted on Aug 17, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

APE08AJM1 - GE 115 Volt Portable Electronic Room Air Conditioner - Compressor not kicking on. Manual indicates it's triggering the overload relay? How do I solve this?


There is a start capacitor near the compressor that may be bad. If the capacitor tests OK then the compressor is locked up. A service man can try to get it going with a kicker capacitor but there is no guarantee that that will work.

Sep 14, 2017 | GE Heating & Cooling

2 Answers

My 2004 jaguar x-type ac is not working. the temp gauge inside shows that the ac is on, but nothing is blowing out of the vents. Please advise


check freon level first. You should hear the compressor clutch kick on under the hood when you turn it on. Can you hear and see it come on and start spinning the compressor?

Aug 15, 2011 | 2004 Jaguar X-Type

1 Answer

Have a frigidare wall ac (FAA067P7A). Worked 1st year we had it but problems after. Only time compressor kicks in is when we hit reset button. Then cold air comes out for couple minutes then compressor...


The compressor is stopping on overload. There is either a weak breaker or an electrical problem causing the overload to open the circuit and stop the compressor. It has to be taken apart to determine what is or is not going on.

Aug 03, 2011 | Frigidaire Compact Air Conditioner

1 Answer

LG neo plasma air conditioner does not blow cold air


To get proper cool, keep the tips as follows:
1. Check air filter is cleaned. 2. Check indoor coil is cleaned. 3. Checkindoor blower motor is working. 4. Keep in cool mode. 5. Set temp minimum 3degrees less than room temp.6.Check compressor is working with correctpressure.
Thanks. Helpful?

Jan 04, 2011 | LG LS-J0910HL Heat & Cool Mini Split Air...

1 Answer

Hi my name is Tom, The problem I have is my airconditioner runs and i've also cleaned filters, but it only blows nomal air...it dosen't seem to cool...


To get proper cool, keep the tips as follows:
1. Check air filter is cleaned. 2. Check indoor coil is cleaned. 3. Check indoor blower motor is working. 4. Keep in cool mode. 5. Set temp minimum 3 degrees less than room temp.6.Check compressor is working with correct pressure.

Thanks. Helpful?

Jan 03, 2011 | Heating & Cooling

1 Answer

Hi, my air conditioner was working fine, blowing nice and cold air. I went to the store and when I got back in my car it wasn't blowing any air out hot or cold. Seems like the compressor kicks on, I...


Sounds like your blower motor when out, check voltage at the blower motor connector under the dash passenger side under dash, with key and blower on, if you have voltage blower motor out, also tap on it some time it will turn it on, but if it happens again you will have to replace it.

Jun 11, 2010 | 2005 Hyundai Santa Fe

1 Answer

AC doesn't blow cold air, but refrigerant levels


The low side pressure seems ok the high side would help,Is your compressor cycling and is the air coming out even slightly cool?slight over charge cold effect cooling ability.I wish I could be more help. I will have to think about this one.maybe you could make sure your temp.door is actually in the commanded cold position.

Aug 25, 2009 | 2003 Pontiac Vibe

1 Answer

The air on my 1998 chevy suburban blows but it doesn't get cold. I put free-on in it. It only took a little. The compressor will turn manually & will not kick on. fuse ok. electricity in harness ok....


Probably the electric clutch of the compressor is not working. This is the part that uses the power generated from the drive belt to drive the compressor. Normally if this is working, you would hear a sound in the engine compartment once you turn on the ac. Otherwise you may have only the AC blower spinning. If they check out OK, the thermostat may not be working. Your AC will not engage because it may be getting the wrong signal thermostat.

Jun 15, 2009 | 1998 Chevrolet Suburban

1 Answer

WHEN THE HEATER COMES ON THE FAN STARTS INSTANTLY AND BLOWS COLD


Do you have a heat pump? If so this is normal. You are probably used to a gas furnace. There are heat pumps that do have a delay though. Look on the circuit board in the air handler. There may be a set of pins that say 0-30-60-90 yours may be at 0. Also some digital T-stats offer that function for delay off to get the extra heat or cold from the system. Find out what the model number of the air handler and call the Goodman supplier in your area to see if you have these options.
If you have a gas furnace and it's not delaying the blower there is definately something wrong.

Mar 17, 2009 | Goodman Heating & Cooling

1 Answer

Samsung window unit air conditioner model # AW2402M freezes up one time, and the next time freezes you out of the room. What is wrong with it, Termistat or compressor?


Try to set the thermostat to higher temperature and monitor if the compressor will turn " off " when the room temp. is cool, and turn " on " when the room temp. is high. If does not work then your thermostat is defective. Continue running of compressor with very cold room temp. can build up ice in the unit. The compressora73b784.jpg should shutdown when setting temp. will attain.

Apr 08, 2008 | Heating & Cooling

Not finding what you are looking for?
Haier CPN11XCJ 11,000 BTU Portable Air Conditioner w/Dehumidifier Logo

101 people viewed this question

Ask a Question

Usually answered in minutes!

Top Haier Heating & Cooling Experts

Tom Chichester

Level 3 Expert

35505 Answers

Matt
Matt

Level 1 Expert

46 Answers

Michelle Balcom

Level 2 Expert

87 Answers

Are you a Haier Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...