Question about Cozy Enclosed Front Console Heater 20,000 btuh Propane

2 Answers

Millivolt Generator burnout

I have had this heater for approximately 3 years. It worked great for the first 13 months. ( Warranty expired after 12 months). The millivolt generator gets burned out after about 3 months of use. We have replaced it at least 3 times already and getting ready to replace it again or buy a new heater. The flame must get too hot and eventually the generator has no output to heep the pilot lit. Bench testing the unit after it does not work will send a 500 mV signal, but this is with a high heat propane or MAP gas torch. It does not send a signal with the pilot button held, even for 5 minutes. Why do these units continue to burnout. There is only one manufacturer - White Rodgers. Should there be some sort of deflection shield installed?

Posted by on

  • Anonymous Oct 28, 2008

    I have the same problem gone thru 3 thermopiles the last one lasted only one year I am told they should last 6 years



2 Answers

  • Level 1:

    An expert who has achieved level 1.


    An expert whose answer got voted for 20 times.


    An expert that has over 10 points.


    An expert whose answer got voted for 2 times.

  • Contributor
  • 15 Answers

I doubt that it's the pilot generators themselves that have been failing They normally last for years through any temperatures that a pilot flame can produce. More likely, the gas valve is bad and is trying to draw more current than the generator can supply. You could verify that by connecting one of the "failed" pilot generators to a known good gas valve.

If the problem is consistent you could try measuring the resistances of the two electromagnets in the gas valve. If you compare your readings to those for any other gas valve of similar type (same brand or not), they should be in the same ball park. 12 ohms and 10 ohms are in the same ball park; 10 and 2.3 are not. If the problem is not consistent but intermittent, see if by any chance it (a.) gets better when the valve is stone cold and worse after it's been drawing current for a few minutes, or (b.) gets worse when you mechanically disturb the screws and terminals on the valve or the wires attached to them.

That "750 mv" is just a number. In practice, 400 mv is a pretty respectable output. Even 250 mv is usually enough to operate the electromagnets, provided it doesn't drop much lower than that and nothing else goes wrong.

When the pilot flame is too small, the adjustment on the gas control is rarely the problem (or the solution). Much more often, the orifice (located in the inlet of the pilot burner) is clogged and needs to be reamed out. A #79 drill bit is about right for the job, if you have the patience and dexterity for it.

Good luck, mrtrick2 or anyone following in his footsteps.

Posted on Feb 14, 2008

  • Level 2:

    An expert who has achieved level 2 by getting 100 points


    An expert that got 10 achievements.


    An expert that got 5 achievements.


    An expert that has over 500 points.

  • Expert
  • 288 Answers

This is an odd one. I believe the pilot genarator should be 750 mv, also the flame should cover the top 1/3rd of the probe and have a nice blue color. There is an adjustment screw on the gas valve for the pilot flame. This might do the trick. That or its just possible you have a bad batch of replacement parts.

Posted on Nov 04, 2007


1 Suggested Answer

  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

A 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
The service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Good luck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%


Complete. Click "Add" to insert your video. Add



Related Questions:

1 Answer

Pentair Minimax CH Propane Millivolt Ignition Heaters error E05 what is it?

If you are firing, and then going off and getting an E05, your igniter is to blame. It may be glowing but it's getting weak. The diagnostic goes further but that is usually the fix.. With inactivity, the igniter is always to blame. You really need to fire it off weekly to make it reliable and make sure that your heater is serviced at least one time a year to keep all the internal components operating as designed.

  • Manufacturer Part #: 471291
  • Description: Propane pilot assembly for heaters with millivolt ignition.
  • Retail Cost: Approximately $65.00

Dec 08, 2010 | Pentair Minimax Ch 200,000 Btu Propane...

2 Answers

Wont turn on. Just used it last night.

Many coffeemakers are failing due to the lousy thermal fuses that may be exclusively made in China now. I returned two identical (other make) machines in 6 days because of this cheap part. I took a refund instead of #3. They are often spot-welded to the heater element so must be replaced with the whole element.

Nov 24, 2010 | Keurig B60 Coffee Maker

1 Answer

Coleman Gravity Floor Furnace need millivolt gas valve & pilot ki

Go to and look for a "power pile generator" this is a millivolt thermocouple that may be just what you need to make your heater work again

Nov 12, 2009 | Heating & Cooling

2 Answers

My heater keeps going out. full propane bottle , but it keeps shutting itsef off i have tried it both with 2 full cylinders , and a 20# bottle ,

look in back of the heater where the fuel nozzle goes. you will see a plate with a bunch of holes, the ignitor and the fan. also there is a little button with two wires on it. these wires connect to two spade terminals on the millivolt generator. its sensing bulb is near to the fuel nozzle. the other end with the gland nut goes into the main valve body. when the heater is on, the flame hits the millivolt generator and makes a very small DC voltage which goes through the little disk [an overload] then to the main valve solenoid. if the millivolt generator is good then there is a voltage at the main valve solenoid and it keeps the valve open. in your case it seems 1) the overload is open 2) the generator needs to be replaced. please go to desatech site and order a new generator.

Oct 24, 2009 | Mr. Heater Mr Heater Portable Buddy...

1 Answer

Heater won't ignite.

If you pull the wires that come from the pilot at the gas valve and clean the contacts this may help. If not you may need to replace the pilot generator or the whole pilot assembly.

Sep 25, 2009 | Raypak Millivolt Heater

1 Answer

Have a Triton Millivolt pool heater pilot is lit and nothing!!

Low out put voltage from the pilot generator and/or an open circuit in the control circuit...the most common is a bad pressure switch (dirty filters can hamper pressure switch operation).


1 Answer

Millivolt Generator burnout

I would check the pilot orfice to make sure you have enough of a flame to heat up the generator. You can buy a orfice drill bit and drill it out one size. The pilot should hit the generator toward the center. You should be able to buy a new orfice for the pilot assembly from the place you bought your heater.

Apr 10, 2008 | Cozy Enclosed Front Console Heater 20,000...

1 Answer

Wont run

two things come to mind here. the high limit shutoff and the millivolt generator. the hi limit cutoff is a thing that looks like a metal pill with two wires coming off it. those two wires connect to the two tabs on the millivolt generator cappillary. its purpose is to keep the millivolt circuit closed. The millivolt generator produces a very small (750 ma) voltage which is in turn connected internally in the gas valve to a small electromagnet. with a flame on the voltage is generated and keeps the pilot valve open. replace either or both devices.