It is a Delonghi dehumidifier, DH 90 U. The low temperature light stays on constantly even at 90 degree ambient temp. No water is collecting in the tank. The unit is about 5 years old and has been trouble-free until this. DP

Posted by on

  • powellal Jun 22, 2009

    The email address you sent was for a Honeywell whole house dehumidifier and looks nothing like my small portable Delonghi unit. Please try again.

    DP









×

Ad

2 Answers

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    President:

    An expert whose answer got voted for 500 times.

  • Master
  • 1,952 Answers

If your dehumidifier is running constantly and the water container is not filling up at least once a day, there may be something wrong with the dehumidifier. But if the unit runs constantly and the water container has to be emptied daily, there's just a lot of humidity in the room and the dehumidifier is doing what it's supposed to do.


Dehumidifier with Washable Air Filter, Full Tank Warning Light and ... Low- temp operation down to 41°F. Pre-drilled drain connect with 3' water hose included. ... system that automatically removes moisture from the collection tank. .

Posted on Jun 22, 2009

  • mohammed marika thambi
    mohammed marika thambi Jun 22, 2009

    safemanuals.com/.../DELONGHI/PINGUINO%20PAC700T-_E try this link

×

Ad
  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Genius:

    An expert who has answered 1,000 questions.

  • Master
  • 1,689 Answers

Hello powellal,

here is the manual for the unit as it will be very helpful for you.

http://customer.honeywell.com/techlit/pdf/69-0000s/69-1951.pdf

regards,

voodoo

Posted on Jun 20, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

The dehumidifier can run all day and will not collect water in the bucket. I have set i according to directions.


Joanne, There are 5 basic, yet solvable reasons for what you described. Please pay particular attention to numbers 1 & 2.

1. The humidity extraction level is set to HIGH. Lower it to 32-35%.

2. Air intake filter is dirty or clogged. Turn unit OFF, & Unplug the
Unit, before removing to inspect & clean it, if necessary. If washed,
allow filter to completely dry before reinstalling. DO NOT operate
the unit without the filter.

3. Obstructed air flow. Maintain a minimum of 12 to 18" of clear air
space around the entire unit.

4. Cooling coils are dirty and need to be cleaned. Use warm water & dish washing liquid to
clean the coils. Rinse and wipe dry. Apply a light coating of WD40 to the coils.

5. Ambient air temperature at floor level is between 40 - 60 degrees.
dehumidifiers do not work well between those temperatures
(Unless, you have a Low Temp Unit). This applies mainly to
where the air temperature at floor level is colder than at shoulder level
in basement applications. Raising the unit up off the floor,
onto a sturdy table, counter top, etc, that can handle the weight
of the unit, plus a full tank of water, will usually resolve this
problem.

If none of the above solves the problem, it may be a case of the compressor needs to be recharged with refrigerant gas or that the humidity condenser sensor has failed. These things usually occur in units that are 5 years old or older. It's rare in a unit younger than that. But, it can happen.

I hope his helps you to troubleshoot & solve the problem. Thanks for choosing FixYa.

Sep 20, 2011 | DeLonghi Dehumidifiers

1 Answer

We have a LG dehumidefier and it runs well but NO water collects in bucket even when set to low humidity and is 1 foot away from the wall.Screen is clean. Please help SW


Since you have eliminated 3 of the basic reasons , which can cause the problem you're having, I just ficus on 2 of them.

4. Cooling coils are dirty and need to be cleaned. Use warm water & dish washing liquid to
clean the coils. Rinse and wipe dry. Apply a light coating of WD40 to the coils.

5. Ambient air temperature at floor level is between 40 - 60 degrees.
dehumidifiers do not work well between those temperatures
(Unless, you have a Low Temp Unit*). This applies mainly to
where the air temperature at floor level is colder than at shoulder level
in basement applications . Raising the unit up off the floor,
onto a sturdy table, counter top, etc, that can handle the weight
of the unit, plus a full tank of water, will usually resolve this
problem.

* Your model is not a low temp unit.

If none of the above solves the problem, it may be a case of the compressor needs to be recharged with refrigerant gas or that the humidity condenser sensor has failed. These things usually occur in units that are 5 years old or older. It's rare in a unit younger than that. But, it can happen.

Hope this helps you to further troubleshoot & solve the problem. Thanks for choosing FixYa..

Sep 15, 2011 | LG LHD65EBL Dehumidifier

1 Answer

We just bought a new Friedrichs dehumidifier for our damp basement. The temp is reading 81 and the humidity 63 and it's been running for 2 hours. The basement is about 1000 sq feet and the outdoor temp...


Iris, all dehumidifiers generate some heat while in operation. However, it may be generating higher temps because of it's location. Dehumidifiers don't work well in temperatures below 65 degrees, In fact they struggle below that temp. Unless it's a Low Temperature unit, designed specifically for basement applications.

For example, the ambient air temperature never changes more than 10 degrees F throughout the year.
The air temperature at floor level (where the dehumidifier is placed) is colder then the air temperature at shoulder level. Raising the unit up off the floor onto a sturdy table, counter top, etc, that can handle the weight of the unit, plus a bull bucket of water, will generally solve the problem.

Be sure to clean the air intake filter regularly. At least once every 2 weeks. And wipe off the cabinet and the front louvers, when you change the filter. Always, turn the unit OFF & Unplug it, before removing the filter. Never operate the unit without the filter in place. Doing so could cause damage to the unit.

I hope this information has helped you and thanks for choosing FixYa.

Aug 26, 2011 | Friedrich D50 Dehumidifier

1 Answer

Dehumidifier runs but collects no water.


There are 5 basic, yet solvable reasons for what you described. Please pay particular attention to numbers 1 & 2..

1. The humidity extraction level is set to HIGH. Lower it to 32-35%.

2. Air intake filter is dirty or clogged. Turn unit OFF, & Unplug the
Unit, before removing to inspect & clean it, if necessary. If washed,
allow filter to completely dry before reinstalling. DO NOT operate
the unit without the filter.

3. Obstructed air flow. Maintain a minimum of 12 to 18" of clear air
space around the entire unit.

4. Cooling coils are dirty and need to be cleaned. Use warm water & dish washing liquid to
clean the coils. Rinse and wipe dry. Apply a light coating of WD40 to the coils.

5. Ambient air temperature at floor level is between 40 - 60 degrees.
dehumidifiers do not work well between those temperatures
(Unless, you have a Low Temp Unit). This applies mainly to
where the air temperature at floor level is colder than at shoulder level
in basement applications. Raising the unit up off the floor,
onto a sturdy table, counter top, etc, that can handle the weight
of the unit, plus a full tank of water, will usually resolve this
problem.

If none of the above solves the problem, it may be a case of the compressor needs to be recharged with refrigerant gas or that the humidity condenser sensor (aka Humid-i-stat) has failed. These things usually occur in units that are 5 years old or older. It's rare in a unit younger than that. But, it can happen.

I hope this helps you to troubleshoot & solve the problem. Thanks for choosing FixYa.

Aug 23, 2011 | DeLonghi DE500P Dehumidifier

1 Answer

When the dehumidifier runs it forms ice on the top of the unit and does not collect much water in the bottom.


The problem you described can be caused by 3 things:

1. The air intake filter is dirty or clogged and needs to be removed and cleaned.

2. The cooling coils are dirty and need to be cleaned. Turn the unit OFF & unplug it before attempting
to clean the coils with warm water and mild dish washing liquid. Then rinse and wipe dry. A light
coating of WD40 will help them stay clean.

3. The dehumidifier is being operated in a basement, where the air temperature at floor level is
below 65 degrees. When this happens dehumidifiers struggle at temps below 65 degrees F
unless it its a Low Temp model, designed for basement applications. Raising the unit up off
the floor onto a sturdy table or counter top, that can hold the weight of the unit, plus a full tank
of water, will generally resolve this problem.

I hope this helps you to troubleshoot & solve the problem. Thanks for choosing FixYa.

Aug 09, 2011 | LG LHD65EBL Dehumidifier

1 Answer

Basement smells musty, fan won't stay on continuous


Barbara, are you running the unit in a continuous mode (i.e Using a hose to drain the unit)? Or is the water draining into the water collection bucket?

If you are not using a hose for continual drainage, the fan will not run constantly. It requires that, for continual operation.

Also, you may have the humidity extraction level set to high. Lower it to 35%. Also, remove and check the air intake filter, as it may need cleaning.

Dehumidifiers that are not Low Temp models have a difficult time operating in basement applications. Because the air temp at floor level is colder than at shoulder level. At temperatures between 40 & 60 degree F, regular dehumidifiers struggle to keep up. Raising it up off the flow on to a sturdy table, counter top, etc that can handle the weight of the unit, plus a full bucket of water can really help.

I hope this was of assistance and thanks for choosing FixYa.

Jul 29, 2011 | LG LHD459EL Dehumidifier

1 Answer

My dehumidifier as stopped extracting water and has started icing up


There are 4 basic, yet solvable reasons for what you have described.

1. Air intake filter is dirty or clogged. Turn unit OFF, & Unplug the
Unit, before removing to inspect & clean it, if necessary. If washed,
allow filter to completely dry before reinstalling. DO NOT operate
the unit without the filter.

2. Obstructed air flow. Maintain a minimum of 12 to 18" of clear air
space around the entire unit.

3. Cooling coils are dirty and need to be cleaned. Use warm water & dish washing liquid to
clean the coils. Rinse and wipe dry. Apply a light coating of WD40 to the coils.

4. Ambient air temperature at floor level is between 40 - 60 degrees.
dehumidifiers do not work well between those temperatures
(Unless, you have a Low Temp Unit). This applies mainly to
where the air temperature at floor level is colder than at shoulder
level
in basement applications. Raising the unit up off the floor,
onto a sturdy table, counter top, etc, that can handle the weight
of the unit, plus a full tank of water, will usually resolve this
problem.

I hope this helps you troubleshoot & solve the problem. Thanks for choosing FixYa.

Jul 25, 2011 | DeLonghi DE500 Dehumidifier

1 Answer

DE' Longhi Dehumidifier - Model: DH=25 - Water does not empty into bucket.


If you're saying the dehumidifier is not extracting moisture from the air?

There are 5 basic, yet solvable reason for this. Please pay particular attention to numbers 1 & 2..

1. The humidity extraction level is set to HIGH. Lower it to 32-35%. If yours is a manual unit, turn
the control knob to Maximum.

2. Air intake filter is dirty or clogged. Turn unit OFF, & Unplug the
Unit, before removing to inspect & clean it, if necessary. If washed,
allow filter to completely dry before reinstalling. DO NOT operate
the unit without the filter.

3. Obstructed air flow. Maintain a minimum of 12 to 18" of clear air
space around the entire unit.

4. Cooling coils are dirty and need to be cleaned. Use warm water & dish washing liquid to
clean the coils. Rinse and wipe dry. Apply a light coating of WD40 to the coils.

5. Ambient air temperature at floor level is between 40 - 60 degrees.
dehumidifiers do not work well between those temperatures
(Unless, you have a Low Temp Unit). This applies mainly to
where the air temperature at floor level is colder than at shoulder level
in basement applications. Raising the unit up off the floor,
onto a sturdy table, counter top, etc, that can handle the weight
of the unit, plus a full tank of water, will usually resolve this
problem.

If none of the above solves the problem, it may be a case of the compressor needs to be recharged with refrigerant gas or that the humidity condenser sensor has failed. These things usually occur in units that are 5 years old or older. It's rare in a unit younger than that. But, it can happen.

I hope this helped you to troubleshoot and solve the problem.

Jul 14, 2011 | DeLonghi DH-25G Dehumidifier

2 Answers

Does not collect water in bucket but runs all the time


Does it have a filter?
http://whirlpool.custhelp.com/app/answers/detail/a_id/953

also:

"
It may be that the humidity level or temperature in the room where your dehumidifier is located is too low.

When the outdoor temperature is below 50 F, the indoor air will be dry even when the air inside is warm, therefore when it's cold outside the dehumidifier may collect little or no water.

Air conditioners will also remove moisture from the room, even if it's hot and humid outside, resulting in little or no moisture collecting in the dehumidifier bucket.

Some dehumidifiers have a deicer which turns off the compressor but keeps the fan running. When the compressor is off, moisture is not removed from the air. The deicer turns off the compressor when the room temperature is cold.

Some dehumidifiers do not have a deicer. If the room temperature is low enough, ice may form on the evaporator coil. The ice prevents the dehumidifier from removing and collecting water. If ice forms on coils, unplug dehumidifier until ice melts and room temperature rises."

Jun 21, 2011 | Whirlpool AD25BBK Dehumidifier

1 Answer

My challenge dehumidifier runs ok but does not collect any water , whats the problem?


low outside temp means low inside humidity

If the room temperature is close to 60, the coils may be frozen (completely encased in ice). If this is the case, move it where the water can drain off - about 1 gallon which may NOT run into the drain bucket.
I out mine over the floor drain.
Turn off and it will defrost over night.
Only specially made dehumidifiers work below a room temp of 60 degrees (the temp of a basement in winter).
Does it need to be running? A digital humidity sensor from Radio Shack is cheap and may tell you the humidity is OK - only 50% or less.

Dec 20, 2009 | DeLonghi Dehumidifiers

Not finding what you are looking for?
Frigidaire FDL50R1 Dehumidifier Logo

Related Topics:

117 people viewed this question

Ask a Question

Usually answered in minutes!

Top Frigidaire Dehumidifiers Experts

Lawrence Oravetz

Level 3 Expert

9633 Answers

mike cooper

Level 3 Expert

884 Answers

Are you a Frigidaire Dehumidifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...