Cannot get new digitical timer to work have 2 black wires in wall box but new timer has black, blue,green,red, and white

Posted by Anonymous on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Intermatic Master
  • 5,245 Answers

Red wire is used for 3-way only... cap off for single pole
White is neutral, black is hot, blue goes to load, green is ground
Copy following link for wiring your timer:
http://waterheatertimer.org/How-to-wire-GE-15312-timer.html

If box does NOT have white wires twisted together and covered with wire nut: then suggest to buy Ei600 or ST01 battery operated timer
http://waterheatertimer.org/Intermatic-timers-and-manuals.html#ST01C

Gene

Posted on Aug 12, 2014

  • Jonathan Jones
    Jonathan Jones Aug 04, 2015

    for u people that keep giving answers, u need to read the whole question, so the switch has a black red blue white and green, what are the red and blue wires for and please explain this so a six year old could understand it please, for instance what is load???

  • Gene Haynes Aug 04, 2015

    You are probably looking at a suggested answer from previous date, and not live answer. Right now, I am writing a live answer Aug 4. I cannot see your live question. OK... a load is any light bulb, motor, refrigerator etc that consumes electricity. OK... do you have a switch or a timer? You say your switch has red, blue, green and black and white ... If you have a timer, instead of a switch, please look at the links in original question for GE15132 timer... this timer has the exact wires you describe. Open the link, and look at the timer to see if it matches your timer... and then look at the wiring diagrams... it can be wired a lot of different ways: If this is NOT your timer, or if you have a switch, then include the model number and include what the switch does:http://waterheatertimer.org/How-to-wire-...

×

Ad

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
New users get to try the service completely Free afterwhich it costs $6 per call and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
  • 351 Answers

SOURCE: Trying to replace Intermatic with Utilitech inwall

The wires on your new switch are intended for black = power .. white = neutral . and red = lights .. with two black wires on the old switch I am assuming that there is a bundle of white wires in that wall box, the white timer needs to join that bundle ... then you need to determine which black wire is the power from the electrical panel ( voltage tester) and connect to the black timer wire .. the red timer wire connects to the other black wire in the wall..

Please Vote !!

Posted on May 13, 2010

  • 351 Answers

SOURCE: I bought a Utilitech 7 day digital in wall timer,

HI .. if the switch has only a black and white wire attached, and there are no other wires in the wall box, then you cannot use this timer switch. You need to return it and get a timer that does not use a neutral connection. The wires you have are a switch leg from the light and there is a white wire but it is not a neutral.
If there are other wires in that wall box , tell me and we can chat more about how to remedy this .

Please Vote !!

Posted on May 25, 2010

  • 1 Answer

SOURCE: I bought Utilitech #0141224 7

Hello, I bought an in door smart digital timer (G.E.) or Jasco product for my front porch light. I hooked all the wires as instructed and programmed according to instructions. I have a two wire system, so i left the green wire unattached. The light comes on but flashes very fast. What's up with that? This is the second one i've replaced, the first one did the same thing!. Whats wrong?
Thanks,...
M Jones
Sacramento, CA.

Posted on Sep 13, 2010

SOURCE: Utilitech Wall Timer #0192773 does not switch

Old timer: Intermatic EJ500 & ST01C timers have a battery. Battery operates the clock motor. Red wire is for 3-way circuit [a hallway with 2 switches is a 3-way circuit].

Utilitec timer, clock runs on 120Volt circuit instead of battery. So clock has to have power.

How to connect wires:
Black timer wire connects to hot wire from breaker box.
Red (or blue) timer wire goes to landscape lights.
White timer wire connects to white neutral wire [or if no neutral is available, connect to bare ground wire].
Green timer wire goes to bare ground wire.

How to find black hot wire and white neutral wire inside box
: Disconnect and separate wires so you can test. Use ordinary tester. Power is on. There is only 1 black hot wire inside each electrical box. Test each black wire to bare ground until tester light comes on > that identifies the black hot wire. Next, test black hot wire to white wires until tester light comes on > that is the neutral wire. Exception: This test does not necessarily work with 3-way switches since they reverse each time switch is thrown.

Posted on Sep 21, 2010

SOURCE: GE digital timer. Instructions say to: 1)

Find the Hot wire:
Your switch has 2 wires. One of these wires is Hot, and one goes to load. Disconnect wires from switch. Turn on power. Do not stand on wet surface. Test each wire to bare copper wire. When tester lights up, that is Hot wire. The other wire goes to load.

Connect wires:
Hot wire goes to Black timer wire
Wire to load goes to Red timer wire
White wire connects to white wires that are twisted together
Bare copper wire connects to Green wire from timer

How to connect white wire to white wires that are twisted together.
a) Strip white timer wire so you have 1-1/2 " of bare wire. Stranded wire will wrap around other wires easily.
b) Remove wire nut. DO NOT UNTWIST wires.
c) Hold all whites together so bare copper lines up. Wrap stranded copper around the twisted wire.
d) Replace wire nut, or use larger wire nut. Twist real tight. Do not use tape. You can solder the connection.
e) When done, pull on white time wire to make sure it is held tight. Push whites back into box.

Posted on Sep 26, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

Replace et724-A with new digital timer 15313


You are install GE 15313 timer
Open following link to identify timer
http://waterheatertimer.org/GE-timers-and-manuals.html#15312

15313 timer does not require Neutral wire.
The timer you are replacing has neutral wire (White wire)
So replace timer wires 1:1 except do not connect timer to white neutrals.

Keep in mind the 15313 is for incandescent lights only and is not for CFL or LED lights.
If you want timer for CFL, then install one of the other timers shown on page.

Apr 29, 2012 | Intermatic Inc. EJ500C Digital Wall Switch...

1 Answer

Purchased utilitech 0192773 self adjusting wall timer. planning on installing in garage wall switch box for outside lamp posts, 3 total. the wiring in switch box consists of grounds tied together, 2 whites...


you got the wires you need. add switch's white to the white bundle in the back; green to grounds, red to the black going to the light; black to the other black. worked for me!

Jan 29, 2011 | Computers & Internet

1 Answer

Only have two wires to connect to


What timer are you installing?

Intermatic battery-operated timer with red, blue, black and green
Green connects to bare ground
Red is capped off.
Blue connects to one wire
Black connects to other wire
Push on-off button: if light comes on, timer wiring is correct.
If light does not come on, then reverse blue and black wires.

Other in-wall timers except Aube have red, black, white and green
Green goes to bare ground
Red connects to one wire
Black connects to other wire.
White: in back of electrical box are white wires twisted together and covered with wire nut. Connect white white to these other white wires.
If box does not have white wires described above, then connect white wire to bare ground along with green wire.
Push on-off or override switch: if light comes on, timer wiring is correct.
If light does not come on, then reverse red and black wires.

Dec 13, 2010 | Intermatic Inc. ST01C Digital In-Wall...

1 Answer

When I press the timer to go on my three outdoor lights go on and off, timer clicks that way too


Timer is wired incorrectly.

1) If you have battery-operated Intermatic EJ500 or ST01C, with red, blue, black and green wires:
Then red wire is where blue wire should go. Swap blue and red wire.

2) If you have Aube battery-operated timer, add a comment and say if you are replacing single-pole or 3-way switch. And say where each wire is so far.

3) If you have GE Tork Intermatic UPM Woods Brinks Hagar Pass-n-Seymour Stanley Westek in-wall timer, with red, black, white and green wires, then you probably put red and white wires together.
Add a comment any time.

See instructions along with image at following link:
http://waterheatertimer.org/Program-wire-Utilitec-0192773.html

Heres how to wire timer

1) Timer-green-wire connects to bare ground wire.
2) Switch has 2 wires. Take switch wires and connect them to timer-black-wire and timer-red-wire. Choose either one for now.
3) In back of electric box are white wires twisted together and covered with wire nut. Connect timer-white to these wires.
4) If electric box does not have white wires described above, then connect timer-white to bare ground, along with timer-green wire.
5) Turn on electricity, and push ON-OFF button. If lights come on, timer is wired correctly. If lights do not come on, then reverse timer-red and timer-black wires.

Dec 11, 2010 | Woods Hardware & Accessories

2 Answers

I'm trying to install this for our outdoor Christmas lights. The wall switch box has 1 black, 1 white, and 1 bare (ground). Where do I connect the red "timer" wire from the timer unit? When I...


Single pole application, red wire is capped off.
http://waterheatertimer.org/ST01C-program.html#ST01C

That being said, you still have to connect Blue and Black wires correctly.
Switch has two wires, if you do not know which wire is which, follow instructions below.
Connect Blue and Black to either wire.
Turn on power.
Push ON-OFF button.
If lights work, then timer is wired correctly.
If lights don't work, then reverse Blue and Black.

Be sure outdoor bulb is working.
I have a long story about that, and tested every wire and breaker ... and bulb was burned out.

Nov 28, 2010 | Intermatic Inc. ST01C Digital In-Wall...

1 Answer

Am replacing an old wall timer with a GE Smart Digital Timer. The old timer had two black wires connected to two black wires from the wall. The new timer however has red, black, white and green wires. I...


I've tested these timers.
Here's what to do:
1) Connect green to bare copper
2) Switch has 2 wires. For now, connect these two wires to timer-black and timer-red. Choose either one.
3) In back of wall box are white neutral wires twisted together and covered with wire nut. Timer-white wire connects to these white neutral wires. This action gives power to time clock.
4) If wall box does not have white neutrals described above, then connect timer-white to bare ground wire. Bare ground connects to neutral busbar in breaker box.
5) Turn on power and click manual override button or switch. If lights turn on, timer is wired correctly. If lights do not turn on, then reverse timer-red and timer-black wires.

Nov 16, 2010 | GE 60minute Automatic ShutOff Timer Switch...

2 Answers

Utilitech Wall Timer #0192773 does not switch landscape lights on? Replaced Intermatic that had 3 wires. Black to Black, blue to black and red was capped. Utilitech came with 4 wires - black, white,...


Old timer: Intermatic EJ500 & ST01C timers have a battery. Battery operates the clock motor. Red wire is for 3-way circuit [a hallway with 2 switches is a 3-way circuit].

Utilitec timer, clock runs on 120Volt circuit instead of battery. So clock has to have power.

How to connect wires:
Black timer wire connects to hot wire from breaker box.
Red (or blue) timer wire goes to landscape lights.
White timer wire connects to white neutral wire [or if no neutral is available, connect to bare ground wire].
Green timer wire goes to bare ground wire.

How to find black hot wire and white neutral wire inside box
: Disconnect and separate wires so you can test. Use ordinary tester. Power is on. There is only 1 black hot wire inside each electrical box. Test each black wire to bare ground until tester light comes on > that identifies the black hot wire. Next, test black hot wire to white wires until tester light comes on > that is the neutral wire. Exception: This test does not necessarily work with 3-way switches since they reverse each time switch is thrown.

Sep 14, 2010 | Intermatic Inc. ST01C Digital In-Wall...

1 Answer

I am trying to install utilitech 7 day in-wall timer. Their are 3 switches in box controlling different fixtures. The old switch had black connected and a black looped to the next switch. How do I connect...


1) Wires in box:
Black looped to to next switch is Black hot wire
Other Black goes to fixture

2) Connect timer wires
Black timer wire goes to Black hot
Red (or Blue) timer wire goes to fixture
White wire connects to white neutral wires (usually connected together with wire nut and pushed to back of box)
Green goes to bare ground wire

Sep 04, 2010 | Intermatic Inc. ST01C Digital In-Wall...

1 Answer

Hello, I have 2 black wires coming from the junction box, and a copper ground wire. I connected the green wire to the ground. Where do I connect the red, white, and black wires?


The timer should have red, black,blue and green wires. (no white?) If you have only the two black wires coming from junction box, then connect green to ground like you did. Connect the incoming black (HOT) to the black wire on the timer.connect the outgoing (to the light) to the blue wire on the timer. Cap of with wire nut the red wire. This is for a single pole switch installation (Only switch for the light) If this is for a 3-way control (where you have 2 or more switches) then you use the red.

Aug 05, 2010 | Intermatic Inc. ST01C Digital In-Wall...

1 Answer

Trying to replace Intermatic with Utilitech inwall timers. Have 2 black wires in wall box with other switches for other lights. Which of the Utilitech 4 wires- black, red, white & green get conected to...


The wires on your new switch are intended for black = power .. white = neutral . and red = lights .. with two black wires on the old switch I am assuming that there is a bundle of white wires in that wall box, the white timer needs to join that bundle ... then you need to determine which black wire is the power from the electrical panel ( voltage tester) and connect to the black timer wire .. the red timer wire connects to the other black wire in the wall..

Please Vote !!

Apr 08, 2010 | Intermatic Inc. EJ500C Digital Wall Switch...

Not finding what you are looking for?
Hardware & Accessories Logo

Related Topics:

213 people viewed this question

Ask a Question

Usually answered in minutes!

Top Intermatic Hardware & Accessories Experts

Gene Haynes

Level 3 Expert

5245 Answers

Jay Finke
Jay Finke

Level 3 Expert

1343 Answers

Hippy_dd

Level 2 Expert

112 Answers

Are you an Intermatic Hardware and Accessory Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...