Air compressor can't start (hums) under pressure

Just bought a used Campbell Hausfeld 1.5 HP 11 gal. ''Super Pal'' 110v electric air compressor. Hasn't been used much in last few years. Has trouble starting under pressure (hums). Will start from 0 psi and go to 90 and auto shutoff, sometimes only makes it to 80 psi, then stalls (humming). Can't restart until about 15 psi. Same results in two different garages.

Posted by on

  • zauggs Jun 24, 2009

    Thanks for your reply. It turned out to be burned contacts in the
    pressure switch, so the motor wasn't getting full current and didn't
    have the umpf to start when there was pressure in the tank. The
    unloader valve was working OK. When starting at 0 psi, in could
    maintain enough momentum to reach shut off pressure. thanks again!

×

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Sergeant:

    An expert that hasĀ over 500 points.

    Champion:

    An expert who has answered 200 questions.

  • Expert
  • 266 Answers

Maybe high pressure vavle is bad

Posted on Jun 20, 2009

Ad

2 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
  • 174 Answers

SOURCE: Air compressor motor stalls under pressure

this sounds like a bad pressure switch.if the unit is not shutting off at the same pressure each time this would be the cause.2 if the pressure is not unloading the air pressure on the compressor side of the unit it will cause the unit to struggle when it starts a cycle because the piston is under a load .how this works is say the unit starts from 0 psi when it get to the desired pressure you have it set on the unit kicks off . the other adjustment most units have on them is what pressure to cycle back on.so when the unit reaches say 100 pounds ,it kicks off and bleeds the air off the compressor side so when it starts back up it wont start up with pressure on the piston.

Posted on Jun 22, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My Campbell hausfeld air compressor runs to 20 psi and then motor starts to bogg and then stops but motor still trying to run? Please help!


dont know size of unit ---if 220 check power in- under that will bog motor same with 110v --if using extension cords to long a feed from source and your voltage drops from resistance in wires ---motor may need service oil bearings --same with compressor motor oil change/needs oil added

Jul 12, 2016 | Campbell Hausfeld Air Tools & Compressors

1 Answer

Electric compressor motor problem


Unloader valve on switch. That switch is not bleeding off cylinder head pressure,when it shuts off.

Apr 06, 2010 | Campbell Hausfeld 26 - Gallon Air...

1 Answer

Compressor trips breaker on re-load


if it has been an on going problem i would suspect that your power cord is too small,try a outlet closer to the breaker system.or get a bigger cord if one is used.is it maintaining pressure in the tank?if not a check valve is defective,you should hear air leaking if this is the case.let us know.

Mar 21, 2010 | Campbell Hausfeld Air Tools & Compressors

2 Answers

Need new pressure regulator for Campbell Hausfeld


their web site is chpower.com can order on line if not to old can check warranties also they can direct u to service location in ur area

Feb 01, 2010 | Campbell Hausfeld Air Tools & Compressors

1 Answer

Air compressor motor stalls under pressure


this sounds like a bad pressure switch.if the unit is not shutting off at the same pressure each time this would be the cause.2 if the pressure is not unloading the air pressure on the compressor side of the unit it will cause the unit to struggle when it starts a cycle because the piston is under a load .how this works is say the unit starts from 0 psi when it get to the desired pressure you have it set on the unit kicks off . the other adjustment most units have on them is what pressure to cycle back on.so when the unit reaches say 100 pounds ,it kicks off and bleeds the air off the compressor side so when it starts back up it wont start up with pressure on the piston.

Jun 18, 2009 | Air Tools & Compressors

1 Answer

Compressor runs hot and won't build pressure


THE COPPER LINE IS SUPPOSED TO GET HOT, SCALDING HOT ACTUALLY. THE MOST COMMON REASON FOR COMPRESSORS NOT BUILDING PRESSURE IS CLOGGED AIR FILTER OR THE VALVES IN THE HEAD ARE BROKEN OR NOT OPENING AND CLOSING CORRECTLY. YOU MAY POSSIBLY HAVE A BAD AIR LEAK DOWNSTREAM BUT YOU CAN CLOSE THE DISCHARGE VALVE ON THE TANK TO ELIMINATE THAT PROBLEM. HOPE THIS HELPS OR GET YOU STARTED.

Mar 27, 2009 | Campbell Hausfeld Air Tools & Compressors

Not finding what you are looking for?
Air Tools & Compressors Logo

Related Topics:

521 people viewed this question

Ask a Question

Usually answered in minutes!

Top Air Tools & Compressors Experts

John Trevino

Level 3 Expert

1388 Answers

Joe Garcia
Joe Garcia

Level 2 Expert

205 Answers

Brad Brown

Level 3 Expert

16195 Answers

Are you an Air Tool and Compressor Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...