Question about Scotsman C0630MR_HD30B-32 684 lb 30" Remote-Cooled Medium Cube Ic

2 Answers

Short freeze Code 8 short freeze cycle

Posted by Anonymous on

2 Answers

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that has over 10 points.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Expert
  • 100 Answers

HOW OLD THIS THIS MACHINE? IT COULD BE THE CONTINUITY SENSORS NEED TO BE DESCALED, DO YOU HAVE WATER RUNNING OUT THE DRAIN DURING ICE MAKING PROCESS TRY AND CLEAN PURGE VALVE OF ANY DEBIS, ICE SENSOR SHOULD BE 3/16 OR 7/32 AWAY FROM EVAP (GAP) ,ALSO GENERAL MAINTENCE IS VERY IMPORTANT FOR ICE MACHINES

Posted on Dec 04, 2014

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that got 5 achievements.

    Novelist:

    An expert who has written 50 answers of more than 400 characters.

    Champion:

    An expert who has answered 200 questions.

  • Scotsman Expert
  • 373 Answers

Ice is to thin. Check to make sure water inlet valve is not letting water go through valve during freeze cycle. Make sure condenser coil is clean and condenser fan is running. Check the hot gas valve to make sure it is not bypassing during freeze cycle.

Posted on Jul 17, 2014

  • Beto Flores
    Beto Flores Dec 04, 2014

    HOW OLD THIS THIS MACHINE? IT COULD BE THE CONTINUITY SENSORS NEED TO BE DESCALED, DO YOU HAVE WATER RUNNING OUT THE DRAIN DURING ICE MAKING PROCESS TRY AND CLEAN PURGE VALVE OF ANY DEBIS, ICE SENSOR SHOULD BE 3/16 OR 7/32 AWAY FROM EVAP (GAP)

×

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Code 8 blinking machine making very thin ice?


Short freeze, thine ice.
Cause: Grounded ice thickness sensor.
Solution: Check sensor for dirt and position. Clean and adjust gap to evaporator surface using 13/64" drill bit as a gauge, lay flat between evaporator plate and ice thickness probe and adjust 1/4 screw 1/8 of a turn clock wise at a time after every harvest cycle. You don't wont the ice any thicker than 13/64 or thinner either. If you are still having problem after cleaning probe then replace it but you will still have to adjust the probe.

Aug 08, 2013 | Scotsman Cooled Modular Contour Cuber Air...

1 Answer

Fault Code 8 Short Freeze


Likely cause.
1. Grounded ice thickness sensor.
Solution, check sensor for dirt and position. Clean and check gap to evaporator surface.

Apr 18, 2013 | Scotsman Cooled Modular Contour Cuber Air...

1 Answer

2 problems one water escaping to the drain freeze cycle short


first, freeze cycle too short because you are loosing water. Water may be leaking thru the dump valve. Look at drain while machine is running and see of alot of water is draining. The dump valve spring may be week or there is trash in the dump valve preventing it from seating properly. drain water first before pulling dump valve apart.

Aug 29, 2011 | Hoshizaki Freezer Commercial Ice Machines...

2 Answers

Long beeps not booting up


problem....the beeps are beep beep beep beep..........contiues...........plus the computer will then not recieve signal????

May 25, 2011 | MSI K9VGM-V Motherboard

1 Answer

English instructions for saivod fhs186 ice maker


DO THE BASICS:
Change the water filter
Add ice machine cleaner and go by the directions.
What should be kept clean?
There are 5 things to keep clean:
1. The outside cabinet & door.
2. The ice storage bin.
3. The condenser.
4. The ice making system.
5. The ice scoop.
The ice storage bin should be sanitized
occasionally. It is usually convenient to sanitize the
bin after the ice making system has been cleaned,
and the storage bin is empty.
A sanitizing solution can be made of 1 ounce of
household bleach and two gallons of hot (950F. -
1150F.) water. Use a clean cloth and wipe the
interior of the ice storage bin with the sanitizing
solution, pour some of the solution down the drain.
Allow to air dry.

How to clean the condenser.
The condenser is like the radiator on a car, it has
fins and tubes that can become clogged. To clean:
1. Remove the kickplate.
2. Locate the condenser surface.
3. Vacuum the surface, removing all dust and lint.
Caution: Do not dent the fins.
4. Replace the kickplate.
Winterizing
1. Clean the machine as explained on the next
page.
2. Turn off the water supply.
3. Drain the water reservoir. See page 24, Spray
Pump Repair and follow the instructions to remove
the pump hose (step 2, bottom hose only).
4. Disconnect the incoming water line at the inlet
water valve.
5Remove control box cover and turn the timer
into the harvest cycle.
6. With the machine operating, blow air through
the inlet water valve; a tire pump could do the job.
7. Drain pump models should have about 1¤2 gallon
of RV antifreeze (propylene glycol) poured into the
ice storage bin drain.
Note: Automotive antifreeze must NOT be used.
8. Replace control box cover. Switch off and
unplug the machine.

CUBE ADJUSTMENTS
There are three items that may be adjusted: Cube
Size, Harvest Time, and Bin Level. Note: Cube
Size and Harvest Time adjustments should only be
done by a qualified service person.
Cube size control.
The cube size control should only be adjusted to
bring the cubes to the correct shape, the overall
size cannot be adjusted. Try to adjust the cube
size control when the ice machine is in the harvest
cycle, or in the first 10 minutes of the freeze cycle.
1. Open the door and remove the control box
cover.
2. Locate the cube size adjustment screw, and to
make fuller cubes, turn the screw clockwise about
1/4 turn. This will make the freezing cycle longer.
3. To shorten the freezing cycle and make cubes
that are not as full, turn the adjustment screw 1/4
turn counterclockwise.
4. After the next freezing cycle, the cubes should
have responded to the adjustment, if another
adjustment is required, do it early in the freeze
cycle.


Diagnostic Codes
Code Description
F - - - - - - - Freeze Cycle
F flashes- - - - Freeze Cycle is Pending
H - - - - - - - Harvest Cycle
H flashes- - - - Manual Harvest
b - - - - - - - Bin is Full
C - - - - - - - Clean Cycle
L - - - - - - - Board Locked
d - - - - - - - Test Mode
O - - - - - - - Off
E - - - - - - - Self Test Failed
1 flashes- - - - Max Freeze - Retrying
1 - - - - - - - Max Freeze Time Shut Down
2 flashes- - - - Max Harvest - Retrying
2 - - - - - - - Max Harvest Time Shut Down
3 - - - - - - - Slow Water Fill
4 - - - - - - - High Discharge Temp
5 - - - - - - - Sump Temp Sensor Failure
7 - - - - - - - Discharge Temp Sensor Failure
8 flashes - - - Short Freeze - Retrying
8 - - - - - - - Short Freeze - Thin ice
All 4 Upper Lights Flashing - Unit Remotely Locked Out

Jul 14, 2010 | Scotsman Ice Maker CM3 30inW Cubed Ice...

1 Answer

Penguin 13500 ac short cycling


UNITS THEMOSTAT IS BAD REPLACE THERMOSTAT IF DONT SOLVE PROBLEM MAKE SURE UNIT IS NOT FREEZING UP AND BOUNCING OFF A "FREEZE STAT" CASING COMPRESSOR TO SHORT CYCLE

Jul 31, 2009 | Dometic Rooftop RV Air Conditioner

1 Answer

Emerson quiet cool cycles every 6 mins


YOU ARE HAVEING A SHORT CLCLE PROBLEM COMPRESSOR SHOULD NOT SHUT OFF UNLESS THEMOSTAT SAY OK AT TEMP OR UNIT FREEZES UP AND FREEZE STAT SHUT COMPESSOR OFF USUALLY REALLY SHORT CYCLING LIKE YOU ARE EXPERANCING IS CAUSE BY COMPRESSOR OVERHEATING OR FAULTY THEMO SHUT OFF ON CMPRESSOR REPAIR SHOULD BE DONE BY LICENCED TECH

Jul 29, 2009 | Dometic Rooftop RV Air Conditioner

1 Answer

Unit compressor keep short cycling not feezing or


replace your compressor relay. that's what goes wrong 99% of the time

Jul 15, 2009 | Whirlpool Gold White-on-White 21.9 cu. ft....

1 Answer

Goldstar Dehumidifier compressor short cycling...


If the coil is freezing up and the compressor is short cycling,there must be a low pressure switch opening, do to either, low on charge or not enough air across the coil.

Jul 05, 2009 | Dehumidifiers

1 Answer

Wont turn on


yes they tell you if there is something wrong

Beep Code Descriptions Document

1 short DRAM refresh failure
2 short Parity circuit failure
3 short Base 64K RAM failure
4 short System timer failure
5 short Process failure
6 short Keyboard controller Gate A20 error
7 short Virtual mode exception error
8 short Display memory Read/Write test failure
9 short ROM BIOS checksum failure
10 short CMOS shutdown Read/Write error
11 short Cache Memory error
1 long, 3 short Conventional/Extended memory failure
1 long, 8 short Display/Retrace test failed

Sep 25, 2008 | Dell Dimension 5100 (D51L1) PC Desktop

Not finding what you are looking for?
Scotsman C0630MR_HD30B-32 684 lb 30" Remote-Cooled Medium Cube Ic Logo

118 people viewed this question

Ask a Question

Usually answered in minutes!

Top Scotsman Kitchen Appliances - Others Experts

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

John Tripp
John Tripp

Level 3 Expert

4654 Answers

Tim Whalen

Level 3 Expert

3072 Answers

Are you a Scotsman Kitchen Appliances - Other Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...