Question about Williams Heating & Cooling

Open Question

Need BTU on wall furnace William 25-35-50 - Williams Heating & Cooling

Posted by Anonymous on

4 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Therinnaiguy
  • 1420 Answers

SOURCE: I have a newly installed 35k btu natural gas wall

The disc is doing its job, saving your life! If the heat exchanger gets too hot this disc is the safety. Find out how hot the heat exchanger is getting and what the disc is rated for. Check that there is air flowing over the heat exchanger keeping it from over heating. If your vent was installed incorrectly it could be keeping too much heat inside the furnace not allowing it to escape to the outside.

Posted on Dec 29, 2009

  • 59 Answers

SOURCE: What's the BTU for an Ultra-Aire wall furnace?

MOST SINGLES ARE 25.000 BTU TO 35.000 DUEL SIDED ARE 50.000

Posted on Apr 21, 2010

Testimonial: "I knew it's either 25k or 35k, just not sure which one. I have a room that is big enough for 25k but not 35k. Thanks though!"

  • 2456 Answers

SOURCE: can you vent a rinnai 38,000 BTU wall furnace through a chimney

No you cannot

Posted on Feb 11, 2012

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Chimney type wall furnace. The furnace won't start However after switch was off for a couple hours and turn on the switch it started. What is a possible problem?


The problem sounds like the thermocouple is not working correctly. After being off for a couple hours allowed it to cool down and reset. Sometimes you can clean the soot build up from it and it will work again. Sometimes they just need replacing. the thermocouple is what the pilot light flame heats up when you turn on the heater. when the thermocouple gets hot it sends a 20 to 60 millivolt signal to the gas valve to activate the gas flow to the main burner.

Feb 16, 2015 | Williams Wall Heaters: 50,000 BTU/Hr...

1 Answer

How to wire a gas valve and thermosat


We need more information. Is this a 30 year old furnace or newer one? The safeties vary greatly.

Nov 22, 2014 | Williams Wall Heaters: 35,000 Btu/hr...

1 Answer

Williams direct-vent wall furnace gas pipes instalation process


There is only 1 way and that is inside the unit, How would your gas line end up outside the wall ?
I suggest you have someone who has experience do this for your safety.

Feb 19, 2013 | Williams 14,000 Btu/hr Direct-Vent Furnace...

1 Answer

How can I clean my suddenly stinky Cozy wall furnace?


It may well need a service if you have not had it done in 12 years this could well be a job for a gas fitter

Sep 13, 2012 | Rinnai Orbis Vented Heater 15,000 BTU Wall...

1 Answer

EMPIRE MANUAL DV2353SG


I believe all the Empire manuals are there to download or read at their website: EmpireComfort.com.

Nov 08, 2011 | Empire Direct Vent Wall Furnace;...

1 Answer

I have a William 14000 BTU wall heater and the pilot don't stay on


Make sure the pilot sensing device is clean and free of any dirt or soote! If not then that will probably be the part you need to replace!

Oct 08, 2010 | Heating & Cooling

1 Answer

What's the BTU for an Ultra-Aire wall furnace?


MOST SINGLES ARE 25.000 BTU TO 35.000 DUEL SIDED ARE 50.000

Apr 20, 2010 | Heating & Cooling

1 Answer

I have a newly installed 35k btu natural gas wall


The disc is doing its job, saving your life! If the heat exchanger gets too hot this disc is the safety. Find out how hot the heat exchanger is getting and what the disc is rated for. Check that there is air flowing over the heat exchanger keeping it from over heating. If your vent was installed incorrectly it could be keeping too much heat inside the furnace not allowing it to escape to the outside.

Dec 29, 2009 | Cozy (W352E) Heater

1 Answer

How to change the orfis from propane to gas on a empire 40,000btu


what is the model # for the furnace. You are going to have to change the pilot orofice and gas valve for natural gas also.

Oct 30, 2009 | Empire Hight Efficient Direct Vent Wall...

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

24 people viewed this question

Ask a Question

Usually answered in minutes!

Top Williams Heating & Cooling Experts

paulcarew

Level 3 Expert

2453 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Mack Baxter

Level 3 Expert

381 Answers

Are you a Williams Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides