I have a CWC 1600 everything works fine on it but it does not get cold. Everything powers on fine and you can adjust the temp up and down but it just does not get cold.

Posted by on

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    Welcome Back:

    Visited the website for 2 consecutive days.

    Mayor:

    An expert whose answer got voted for 2 times.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 5 Answers

Your Peltier is most likely shot! You can fix it for less than $10 in about 30 minutes.
Take the back of the fridge apart and remove the fan and aluminum heat-sync. Sandwiched in between the heatsync you'll see the Peltier pad with two wires coming off it. That's what you need to replace. The peltier has a make and model number on it. I would recommend ordering the same make and model. The specs should be 12v DC and less than 5amp and 60 watt draw. Your wine cooler's power supply can only output 5amp and 60watt max power. When you install the new Peltier you'll need to spread new thermal compound on both sides of the Peltier. I recommend Artic Silver Ceramique. You can buy this at your local Radio Shack or any computer store where they sell motherboards and CPUs.
Ceramique Thermal Compound

Posted on Apr 14, 2014

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

Is there a replacement circuit board for the Cuisinart CWC-1600 unit?


The actual manufacturer of the circuit board out of China does not seek direct, but you may be able to order a replacement board through cuisinart support. More than likely your board is fine, but rather your power supply has failed. Check my post on how to replace the power supply for under $20

Jun 17, 2014 | Cuisinart CWC1600 Wine Cooler

1 Answer

TEMP GUAGE JUST QUIT WORKING. COOLANT LEVEL IS FINE, HOSES ARE FINE. EVERYTHING IS COOL TO THE TOUCH. TEMP GUAGE READS BELOW COLD, YET ELECTRIC COOLING FAN COME ON WHEN ENGINE IS SHUT DOWN.


your gage has just gone out and needs to be replace. the computer control the fan. so as long as the temp sensor is connected to the engine it will work fine but you will not know the temp of your vehicle.

Nov 30, 2010 | 2001 Chevrolet Malibu

2 Answers

Side by side refrigerator the refrigerator does not get cold but freeze works fine


Normal 0 MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-fareast-font-family:"Times New Roman";} The fridge gets its cold air from the freezer through a vent(damper) between the freezer and fridge.The fan in the freezer blows air through it. Make sure this fan is running. You may have to hold the door switch in for it to run. There is a flap you adjust with the fridge temp. control. Make sure it's opening and closing when you adjust the fridge temp.
The problem could be the electronic control if you have one or the mechanical linkages.

If the evaporator coils behind the back panel of the freezer are icing up because of auto defrost failure that will stop the circulation of cold air and eventually affect the freezer too.

check defrost timer, defrost heater, defrost thermostat. In most newer models the timer has been replaced by an electronic control board. If the heater and thermostat are ok it’ll be the control.

You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.

Jan 01, 2010 | GE GSS25JFM Side by Side Refrigerator

1 Answer

Ge freezer works fine but the fridge wont cool.you


How to check everything
http://www.acmehowto.com/howto/appliance/refrigerator/refrigerator.php


The fridge gets its cold air from the freezer through a vent(damper) between the freezer and fridge.The fan in the freezer blows air through it. There is a flap you adjust with the fridge temp. control. Make sure it's opening and closing when you adjust the fridge temp.


If the evaporator coils behind the back panel of the freezer are icing up because of auto defrost failure that will stop the circulation of cold air and eventually affect the freezer too.

check defrost timer, defrost heater, defrost thermostat. In most newer models the timer has been replaced by an electronic control board. If the heater and thermostat are ok it’ll be the control.

You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.

Sep 14, 2009 | Refrigerators

1 Answer

My model MFF2557KES refrigerator not getting cold and freezer operating fine.


The fridge gets its cold air from the freezer through a vent(damper) between the freezer and fridge.The fan in the freezer blows air through it. There is a flap you adjust with the fridge temp. control. Make sure it's opening and closing when you adjust the fridge temp ..

OR
How to check everything
http://www.acmehowto.com/howto/appliance/refrigerator/refrigerator.php
If the evaporator coils behind the back panel of the freezer are icing up because of auto defrost failure that will stop the circulation of cold air and eventually affect the freezer too.

check defrost timer, defrost heater, defrost thermostat. In most newer models the timer has been replaced by an electronic control board. If the heater and thermostat are ok it’ll be the control.

You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.

Sep 07, 2009 | Maytag MFF2557KES 25 cu. ft. French Door...

2 Answers

Kenmore Coldspot EM5119829. The Freezer works


The fridge gets its cold air from the freezer through a vent(damper) between the freezer and fridge.The fan in the freezer blows air through it. There is a flap you adjust with the fridge temp. control. Make sure it's opening and closing when you adjust the fridge temp

or..
If the evaporator coils behind the back panel of the freezer are icing up because of auto defrost failure that will stop the circulation of cold air and eventually affect the freezer too.

check defrost timer, defrost heater, defrost thermostat. In most newer models the timer has been replaced by an electronic control board. If the heater and thermostat are ok it’ll be the control.

You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.

Sep 03, 2009 | Refrigerators

1 Answer

Fridge not cold as should be


The fridge gets its cold air from the freezer through a vent(damper) between the freezer and fridge.The fan in the freezer blows air through it. There is a flap you adjust with the fridge temp. control. Make sure it's opening and closing when you adjust the fridge temp .

OR.
If the evaporator coils behind the back panel of the freezer are icing up because of auto defrost failure that will stop the circulation of cold air and eventually affect the freezer too.

check defrost timer, defrost heater, defrost thermostat. In most newer models the timer has been replaced by an electronic control board. If the heater and thermostat are ok it’ll be the control.

You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.

Aug 29, 2009 | KitchenAid Architect KBRA20ERSS Bottom...

1 Answer

Zanussi fridge compartment has stopped cooling but freezer is ok


How to check everything
http://www.acmehowto.com/howto/appliance/refrigerator/refrigerator.php


The fridge gets its cold air from the freezer through a vent(damper) between the freezer and fridge.The fan in the freezer blows air through it. There is a flap you adjust with the fridge temp. control. Make sure it's opening and closing when you adjust the fridge temp .

OR.
If the evaporator coils behind the back panel of the freezer are icing up because of auto defrost failure that will stop the circulation of cold air and eventually affect the freezer too.

check defrost timer, defrost heater, defrost thermostat. In most newer models the timer has been replaced by an electronic control board. If the heater and thermostat are ok it’ll be the control.

You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.


Aug 24, 2009 | Zanussi ZI918 / 12K Bottom Freezer...

1 Answer

Freezer works fine but refrigerator is not cold


The fridge gets its cold air from the freezer through a vent(damper) between the freezer and fridge.The fan in the freezer blows air through it. There is a flap you adjust with the fridge temp. control. Make sure it's opening and closing when you adjust the fridge temp .
OR
.
If the evaporator coils behind the back panel of the freezer are icing up because of auto defrost failure that will stop the circulation of cold air and eventually affect the freezer too.

check defrost timer, defrost heater, defrost thermostat. In most newer models the timer has been replaced by an electronic control board. If the heater and thermostat are ok it’ll be the control.

You can turn the defrost timer till it clicks and everything shuts down. The heater should now come on. If it does, replace the timer. If it doesn't, check the heater and defrost thermostat. Turn the timer again till everything starts back up to end the defrost cycle.

How to check everything
http://www.acmehowto.com/howto/appliance/refrigerator/refrigerator.php

Aug 18, 2009 | KitchenAid Refrigerators

Not finding what you are looking for?
Cuisinart CWC1600 Wine Cooler Logo

527 people viewed this question

Ask a Question

Usually answered in minutes!

Top Cuisinart Refrigerators Experts

yadayada
yadayada

Level 3 Expert

75817 Answers

Darrell

Level 2 Expert

68 Answers

richie46

Level 3 Expert

12869 Answers

Are you a Cuisinart Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...