Question about Kipor Electrical Supplies

1 Answer

My "KDE19STA3" Kipor generator keeps showing fault "L&H Freq.What could be responsible and what can i do? It shuts down about 30seconds after dispalying the fault.

Posted by on

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Master:

    An expert who has achieved Level 3.

  • Master
  • 342 Answers

This is telling you that the power frequency is above or below the safe limit and so shuts down.
do not run a load but
press the function button and hold then switch on but dont start keep holding until ph2 or similar is displayed then start read the frequency and adjust the engine speed until it reads correct then try will full load and adjust accordingly 1 or 2 hz either way will be ok

Posted on Apr 04, 2010

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Kipor KDE12sta generator under/over voltage LED burning, the engine stops after a few seconds


hi
this happens when voltage regulator is at fault .
what happens is that the demand out put is ( volts /amps too high ) and engine power is too low causing engine to stop renew or service voltage regulator

Nov 12, 2017 | Kipor Electrical Supplies

1 Answer

I have diesel generator Kipor kde 19 STA3 . It keeps shoutinng dowen after it starts


First check the oil, A low oil sensor will shut it down if more than a quart low. Then drain your water separator and change fuel and air filters. Anything outside of that is going to be mechanical (lift pump, injection pump)

Jul 17, 2017 | Cars & Trucks

1 Answer

My diesel kipor 5kva generator wont shut by key ,


Caution
the manufacture is recommending a cool down period of about 3 minutes to prevent overheating of the combustion chamber. the following is from the manufacture on shut down procedure.

3.2.8Check Stopping of Generating Set
(1)Disconnect the load from the generating set.
(2)Turn off the air switch of the generating set.
(3)Set the speed lever at RUN position, run the generating set without load for about 3 minutes. Do not stop the engine suddenly, otherwise the temperature will increase abnormally, the nozzle will blocked and the generating set will be damaged.
Press down the stop lever. Concerning the electric starter, turn the key to OFF. Turn the fuel **** lever to S position.
Pull out the recoil starter handle until you feel resistance (at this position, both intake/exhaust valve are closed.) and leave the handle in this position. This prevents the engine from rust.
If the engine keep on running even after the speed lever is placed at the STOP position, either turn the fuel **** to the CLOSE position or loosen the nut of high pressure fuel pipe on the pump side to stop the engine.
Do not stop the engine with the decompression lever.
Do not stop the generating set with load. Stop it after the load removed.

the following link provides the complete maintenance manual for the diesel generator
http://www.rcremers.nl/webshop/handleidingen?download=20:handleiding-aggregaat

Jan 12, 2016 | Kipor Electrical Supplies

1 Answer

My Kipor KDE16STA3 shows p03 error after 15 min runing and shuts down after 3 sec.The voltage drops to 30,40 whta's happening?


[PDF]DIESEL GENERATING SET

www.kipor.com/upload/spec2011053011590766.pdf
3/KDE16STA3/ ..... P-03 Undervoltage: Indicating voltage higher (lower), the generator will self- braking. P-04 Generator ... KDE16STA3 KDE19STA KDE19STA3.

[PDF]2

www.kipor.com/upload/spec2011061109073968.pdf
P-03. Decrease load less than the related load, turn on the breaker. P-04. Replace the fuse of the same type. Check the circuit and inserter. Replace the starting ...

Oct 31, 2015 | Kipor Electrical Supplies

1 Answer

Why unit keeps shutting down after it starts.


Your question is general without specific details. Any one of many things will cause your generator engine to stop running.

Is this question about a Kipor KDE5000TA? If so, your generator is powered by a diesel engine. There are safety shut downs built into the generator to protect the generator head and engine. Do you have any fault codes showing on your control panel display screen? (Trouble codes P-01 through P-05 will be displayed if there's a detected fault)

If you have no fault codes, then you likely have a fuel problem. Do the obvious:
  1. Visually check the fuel level in your tank. DO NOT rely on your fuel gauge. It may be stuck or otherwise not working.
  2. If you have fuel, check your fuel filter. It may be clogged. If your fuel filter is good, you may have water contamination.
  3. Drain your tank and refill with fresh #2 diesel fuel. I use "Diesel 911" with a biocide to prevent water contamination and bacteria growth in my fuel.
  4. Make certain your fuel oil supply and return lines are clear, not leaking, and the fittings are tight.
I know I'm shotgunning, peppering the target. However, I don't have enough information to zero in on a specific area where the problem could be. Good luck!

Apr 26, 2015 | Kipor Generator Diesel Kde5000ta

1 Answer

Yanmar 4TNV88 engine starts,then cuts out after 20-30seconds


It sounds like there is a fuel flow problem. There is a restriction either in the tank or fuel filter that lets enough fuel through to start the engine, but not enough to keep it running.

Mar 17, 2014 | Electrical Supplies

1 Answer

I have generator kipor kde19sta3 when we start then generator after 1 or 2 minutes generator will automatically off and show the fault p 03 so plzzz tell me about p 03 fault thankx


Sounds like an overload on the board. Be sure you're not drawing more amperage out of the plugs on the front of the unit than is listed (typically 12.5 or 20 amps is the limit). If you try and draw more or a surge on the appliance happens during startup, you may end up having to use the 240 volt plug and direct that into a distribution panel to get the 110v unhindered by the plug limitations.

Sep 23, 2013 | Electrical Supplies

3 Answers

My Kipor KDE19STA3 shows lower voltage on one of three phases in control pannel and keep shutting down. Voltage is actually OK on all 3 phases, if I measure it with my voltmeter. I need to adjust measuring...


There is no way to adjust voltage on just one phase. I would check voltage sensing leads and check to see if there is a way to calibrate. Otherwise it sounds like a logic problem.

Jul 08, 2011 | Electrical Supplies

Not finding what you are looking for?
Electrical Supplies Logo

Related Topics:

1,339 people viewed this question

Ask a Question

Usually answered in minutes!

Top Kipor Electrical Supplies Experts

Vernon Taylor

Level 3 Expert

4604 Answers

mark52001p

Level 1 Expert

17 Answers

Jay Finke
Jay Finke

Level 3 Expert

1384 Answers

Are you a Kipor Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...