I have a Bostich coil roofing nailer #RN46-1 leaking air at trigger area when depressed. Replaced trigger assy but same results. Anything else it could be?

Replaced trigger valve assy. but still leaks at trigger when depressed

Posted by on

  • John Trevino May 26, 2014

    Remove the head and pull out the head valve. Check for fine scratches where the orings make contact. If scratched, sand with fine sandpaper (lightly sand the head and also the white plastic headvalve where orings make contact. Apply some white grease to the orings and retest. If deeply scratched, replace the head and the white valve. Good luck.

×

Ad

2 Answers

  • Level 1:

    An expert who has achieved level 1.

    MVP:

    An expert that got 5 achievements.

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that has over 10 points.

  • Contributor
  • 42 Answers

Sounds like your gun needs servicing. normally strip, clean and usually fit new O rings to head valve assy, piston & usually sleeve.

Posted on Apr 11, 2014

Ad
  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    President:

    An expert whose answer got voted for 500 times.

  • Stanley Master
  • 1,388 Answers

Leaking at the trigger on bostitch rn46 with new valve indicates that safety foot is not depressing the firing pin of the trigger valve all the way in. Easy test. Remove the nails, remove the trigger to expose the firing pin of the trigger valve. Connect to 100psi and with very quick motion, depress the trigger pin all the way in. If gun fires, adjust safety foot or replace worn trigger to fix. If gun does not fire, check for worn orings and scratches in head valve. Applying plenty of white grease to headvalve orings will help if oring kit is not available. Good luck.

Posted on Oct 25, 2014

Ad

2 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

  • 7 Answers

SOURCE: constant air leak

Sounds like you need a repair kit or take to a tool company that installs the kit.

Posted on Jun 10, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

2 Answers

Nailer is shooting air out of trigger, is not releasing brad


Sounds like the head valve. Remove the head cap take out the head valve, clean, re-fit and give it a few drops of air line oil. Then give it a try. Good luck.

Oct 19, 2014 | Stanley Bostitch 18 Gauge Brad Nailer 1 -...

1 Answer

Hitachi 45ab blowing air out of trigger


If air leaks thru trigger as soon as you connect airline, replace the vinyl ball under the trigger stem. If air leaks when you depress the trigger, replace the small oring on the trigger stem. If air leaks slightly from plunger in front of the trigger valve, problem is inside of the gun. Remove the head and pull the large circular plate. Replace the large outer oring. Good luck

Feb 10, 2014 | Hitachi NV45AB2 Roofing Coil Nailer

1 Answer

Blowing air out of trigger


Leaking under trigger could be the ball seal part # 875645 if leak starts as soon as you connect the air hose. If no air leaks when you connect hose but begins to leak when you depress the trigger then replace the oring on the plunger which is part # 874820. If air leaks when you connect the hose and the ball mentioned above is good then most likely is leaking from oring # 876161 installed on cylinder plate (remove head and pull out the plate). Good luck.

Feb 10, 2014 | Hitachi NV45AB2 Roofing Coil Nailer

1 Answer

Hitatchi nv45b2 trigger leaking


Air leaking around the trigger area could be caused by vinyl ball / gasket under trigger valve bushing or orings within the gun. Easy test, remove nails and connect air (assuming that air is now leaking around the trigger area). Depressing the trigger stops the leak, replace vinyl ball. Depressing trigger does not stop leak, move plunger b (plunger B, small shaft under bubber bushing next to the trigger valve) with your finger in then out to determine if air leak changes tone. If air leak changes sound or tone, then air is leaking past orings of the cylinder guide and/or cylinder plate and/ or the cylinder itself is scratched by debris where the orings make contact. Pull out the cylinder and examine the contact areas. If scratched, use 300 grit paper to smooth, if smooth, however, suspect the orings of cylinder guide (or cylinder guide is cracked). The cylinder guide is difficult to remove and install without causing damage to guide or cutting new orings when installing. Do not remove the guide unless all the other options have been checked. One last bit if information, I have noticed that some guns will leak air if the orings on the feeder piston do not fit snuggly. Make sure that leaking sound is not coming from feeder area (remove the basket and feeder/feeder pin/spring and pull out the feed piston, making sure that the largest oring is making good contact within the cylinder). Good luck with repair.

Sep 28, 2012 | Hitachi NV45AB2 Roofing Coil Nailer

1 Answer

My hitachi roofing gun leaks air from trigger when not pressed


Two areas to check when air leaks from around the trigger. Rubber ball under trigger pin will cause air to leak, however when good side of the ball falls on the seat, air will not leak for a while. If air is leaking from plunger pin (just in fromt of the trigger pin), remove the head and pull out the cylinder plate to reveal broken oring (oring part # 876161). Good luck with your repair project.

Jun 05, 2012 | Hitachi NV45AB2 Roofing Coil Nailer

1 Answer

Air leaks around green cylinder at trigger area and nail plunger will not retract. this is a stanley bostich rn45b nailer


Your nailer uses a trigger valve (part # tva6 cost about $20) and is sold at www.bostitch.com or generic valves sold on ebay . If you have a source for orings, you could try to repair the valve. Remove the roll pin that holds the trigger to expose the tva6 valve. There are roll pin/pins that hold the valve in just above the valve in the body. Remove these pins and apply air pressure to gun to pop-out the valve. Use caution when you do this. Remove nails, lower pressure to gun and use glove or rag to catch valve because it could come out with force. With tva6 valve in hand remove two pins that hold valve together and remove inner plunger. The middle oring on plunger is cause of leak. Try using an oring about same size as the broken seat. It must fit pretty tight to work. If you had a small leak it could be that the firing pin orings fit too loose or just too worn. Use silicone lube or oring lube on the orings and the valve port. Good holidays.

Dec 02, 2010 | Stanley Bostitch Rn45b1 Industrial Coil...

1 Answer

Hello 2 of my bostich rn-46 nail guns will not fire in the morning after working the day before. What causes this. thanks mike L.


There can be a number of reasons for this. A little more info is needed though (See below). This symptom can be due to a lack of lubrication, the plunger being stuck and not in the fully retracted position, etc.

1) Can you hear any air leaking anywhere?
2) Can you see the location of the plunger (drive pin)?
3) Is there any reaction to the trigger? WIth the trigger held, and hitting the roof, is there any air release or anything at all?

Thanks,
Dan

Sep 26, 2010 | Stanley Factory Reconditioned Bostitch...

1 Answer

Air is leaking through trigger when trigger is not depressed. When trigger is depressed and nail tail cover is in safety position (holding gun in air) it completely stops. The gun fires well but there is...


could be either that or a damaged o ring, when was the last time serviced, all o rings replaced?? could be that the tool needs a thorough cleaning and new one installed. it is not hard

Aug 26, 2010 | Hitachi NV45AB2 Roofing Coil Nailer

1 Answer

Constant air leak


Sounds like you need a repair kit or take to a tool company that installs the kit.

Jun 09, 2009 | Stanley Bostitch Coil Framing Nailer

2 Answers

Air leaks arond trigger when depressed, but no nail fires.


Where does the air leak out from? If it leaks from the trigger DeWalt makes a trigger valve assembly part # 641006-00 list 8.89 BUT if it leaks from other areas we have to look into it deeper. If it is just the trigger valve let me know and I will give you instructions how to remove and install the new one.

Feb 05, 2009 | Dewalt Round Head Framing Nailer D51845

Not finding what you are looking for?
Stanley Bostitch Rn461 Gun Coil Roofing Nailer Logo

545 people viewed this question

Ask a Question

Usually answered in minutes!

Top Stanley Air Tools & Compressors Experts

John Trevino

Level 3 Expert

1388 Answers

yoopertech

Level 2 Expert

131 Answers

Joe Garcia
Joe Garcia

Level 2 Expert

205 Answers

Are you a Stanley Air Tool and Compressor Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...