Question about Heating & Cooling

Open Question

Samsung db98-32889a What is this Air Conditioner's PCB model No.?

Posted by Anonymous on

Ad

3 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad
  • 15 Answers

SOURCE: fixiaI need the code for the remote control SAMSUNG AIR CONDITIONER MODEL SH12ZB9.

hi if you input all the details on the internet the name and the model number it will bring up any relevent sites or type in code number for the remote for your unit and it normally brings a list of codes for different air conditioning units it should be there. Good luck .

Posted on Aug 04, 2014

Testimonial: "hi, can not find the remote control code for the model Samsung SH12ZB9 on the internet, thanks for your help"

Ad
  • 960 Answers

SOURCE: After I replaced the pcb on my samsung air conditioner indoor unit it won't start and all 3 led's are blinking

I have had similar problems with Samsung. Apparently, the indoor board fits a lot of different models and each has to be "programmed" in to suit your model. Not sure what was wrong with your machine before but it has been known for these units to have a faulty outdoor fan motor which causes the outdoor board to fail as well. When this happens, the indoor unit will usually work fine for about a minute or 2 and then shut down, with lights flashing. The outdoor wont start at all. If these were the symptoms, I would suggest putting your old indoor PCB back and then getting a new outdoor fan motor and outdoor PCB.

Posted on Apr 19, 2015

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

After I replaced the pcb on my samsung air conditioner indoor unit it won't start and all 3 led's are blinking


I have had similar problems with Samsung. Apparently, the indoor board fits a lot of different models and each has to be "programmed" in to suit your model. Not sure what was wrong with your machine before but it has been known for these units to have a faulty outdoor fan motor which causes the outdoor board to fail as well. When this happens, the indoor unit will usually work fine for about a minute or 2 and then shut down, with lights flashing. The outdoor wont start at all. If these were the symptoms, I would suggest putting your old indoor PCB back and then getting a new outdoor fan motor and outdoor PCB.

Apr 19, 2015 | Samsung Heating & Cooling

1 Answer

My samsung mini split comes on for a few second and then the turbo button comes on and system turns off


replace your thermistor possible damage it is attach on the main pcb board then observe after replacement.

Mar 04, 2011 | Samsung AP500PF Air Conditioner

1 Answer

Error message CH47


Compressor discharge sensor fault. Disconnect from PCB measure resistance. 237 kOhm at 20°C and 168 kOhm at 30°C. If OK replace PCB, if not replace sensor. Thanks, helpful?

Jan 25, 2011 | Samsung AS18A6RB Air Conditioner

2 Answers

Greeting, I have problem with SAMSUNG air condicioner inverter. The display shows me an error E1 A1 and does not include the external unit, please help what is the problem.


E-1 Room sensor and A1 Indoor PCB fault. Please you replace first,indoor sensor and reset.Sometimes indoor pcb shows fault code due to sensor short. After replacing sensor it will show only A! or sometimes no error. If it shows A1, you have to repair/replace PCB. Helpful?

Jan 24, 2011 | Samsung AW1203B Air Conditioner

1 Answer

Lights are blingking


thermostat command to out door unit not there . Check your PCB

Jul 14, 2010 | Samsung AS18A6RB Air Conditioner

1 Answer

Air conditioner shuts off


C5
Communication Error

• Wrong or missing wiring between indoor and outdoor unit cable

• Defect of communication components in indoor pcb assembly

• Defect of communication components in outdoor pcb assembly

• Defect of power supply components in outdoor pcb assembly

• No ground connection in air conditioner unit

(affected by noise in power source)

Jun 30, 2009 | LG Heating & Cooling

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

22 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

Paul Carew

Level 3 Expert

2557 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides