Navien combi boiler

Randomly runs of of hot water. Shower for 5--7 minutes with hot water than goes completely cold. Turn off water. Wait 3 minutes or so. Hot water is back. Does not happen every shower. Sometimes happens at kitchen faucet after less than a minute of hot water.

Posted by on

Ad

1 Answer

  • Level 1:

    An expert who has achieved level 1.

    MVP:

    An expert that got 5 achievements.

    Greenhorn:

    A rookie expert who has answered 20 questions on their first day.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Contributor
  • 21 Answers

Call in a plumber. it sounds like it is malfunctioning.

Posted on Mar 18, 2014

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

WHEN MY NAVIEN COMBI BOILER GOES TO DOMESTIC USE THE AIR HANDLER DONT SHUT OFF UNTIL IT GOES BACK INTO HEAT MODE DONT KNOW WITCH 2 WIRES TO BRING TO THE NAVIEN WITCH HAS A SPOT NEXT TO TT SAYS A/H


I don't see the above problems being of help because it's not a heat pump or a issue about a fan switch. This is a stat and system wiring issue.
Here's a link to a proper wiring diagram.

https://www.dropbox.com/s/808zsozmkxce7fu/CH_NCB%20AHU%20Wiring.pdf
/uploads/images/when-navien-combi-boiler-goes-domestic-34752482-3-1.jpg

Dec 07, 2014 | Heating & Cooling

1 Answer

Water fluctuating hot and cold on a shower run off a combi boiler


could be a number issues 1 the hot and cold water supply going to shower could be of unequeal pressure thus the fluctuating 2the heat exchanger in your boiler is conjested with debris 3 the gas bed in boiler is cross burning giving an unbalanced "heat pick up"out put !2 &3 would apply if your on a combi boiler system .if your on a conventinal system you could be pulling air from the head of the cyclinder ,

Jan 19, 2011 | Home

1 Answer

My shower is run off a combi boiler and recently started to go cold for a couple of seconds every few minutes and nobody is running water elsware in the house.


Check the hot water flow at the shower - if it's as good as other taps the boiler diverter valve is suspect. Replace either the complete valve or the internal rubber diaphragm, depending on the boiler make

Mar 29, 2010 | Home

3 Answers

Shower goes hot and cold


If you are having trouble only at the one fixture (shower), and no where else, the problem is most likely in the shower valve...which either needs new cartridges, or a complete replacement.
hope this helps

Jan 08, 2009 | Home

1 Answer

No hot water from combi boiler


i have a combie bolier when i turn the hot water taps on only cold water comes out central heating working fine can any one give some advise ?and can i fix it myself.

Jan 03, 2009 | Combi Centre DX - Mango

2 Answers

Combi Boiler - Hot water pressure low


the coil inside got clogged

Dec 22, 2008 | Water Heaters

1 Answer

Installing a Mixer Shower from a Combi Boiler.


hi there, your boiler will perfectly match the mira excel ( a great choice i might add) a 24cdi will give about 9.8 litres a minute flow rate hot water.
The mira excel is suitable for any plumbing set up and there installation instruction are very well laid out & their helpline is fantastic.
The hot water will fluctuate accordingly to the time of year as the cold water temp coming into the property will vary. but the boiler will modulate to compensate.So in brief in the summer you will notice it hotter than you would in the winter, this has nothing to do with the boiler just the incoming temp of the cold water.

Kindly

Richie

Dec 15, 2008 | Home

2 Answers

Have a combi boiler and the hot water from my taps are running cold to luke warm. My British Gas engineer has told me it is nothing to do with the boiler but is caused by a faulty thermostat cartridge in...


Modern shower valves have an "anti scald device" in them to prevent scalding from to hot water.

They come preset at 120 degrees.

Sometimes they can start to malfunction and all you get is warm, not hot water, they can also be intermittent.

This will only effect the shower valve though, not the other faucets.

Dec 06, 2008 | Heating & Cooling

Not finding what you are looking for?
Taco SR503-4 3 Zone Switching Relay Logo

332 people viewed this question

Ask a Question

Usually answered in minutes!

Top Taco Electronics - Others Experts

kakima

Level 3 Expert

102366 Answers

yadayada
yadayada

Level 3 Expert

76164 Answers

Brad Brown

Level 3 Expert

15667 Answers

Are you a Taco Electronics - Other Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...