Question about Dometic NDR 1062 Refrigerator

1 Answer

Does not cool on either ac or gas. there is green fluid to right of coils undera 1 ft cyliner tube.

Posted by on

1 Answer

  • Official Brand Answer
  • 73 Answers

Your cooling unit has leaked, the green fluid you see is the ammonia solution. We are Arcticold Refrigeration. Our NEW replacemnt cooling units come standard with new installation hardware, installation instructions, and a lifetime warranty. Our products are a cost effective solution to buying a new fridge and our units outperform the factory installed units. Our Units are "Built tough to last a Lifetime"Give us a call 1888-782-6665 ArctiCold Refrigeration We keep it cold I have attached a pic bellow of an Arcticold built NDR1062 cooling unit. Does not cool on either ac or gas.  there is green - c9cd0543-0253-4ec8-b002-2cece05f86e6.jpg 3e135613-2b82-4462-bd42-72e04ed7e14f.jpg

Posted on Mar 07, 2014

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Model 42999B troubleshooting


The thermostat has a metal tube that lays against the cooling coils. This tube is filled with a gas that operates a switch to control when the compressor runs. If the tube loses that gas from a leak, you get the result you have now. Replace the thermostat and you're problem will be solved.

Jun 11, 2016 | Heating & Cooling

1 Answer

Worst case diagnosis/cost scenario? front underbelly damage,hit 1' tall stake in ground. hissing sound ~5 sec & a/c fluid leaked by radiator gills. a/c blows warm air.


the damage will be a punctured condenser for the ac system
the green oil is the compressor oil that is circulated with the gas
you will not see the gas as it evaporates as soon as it hits the air. Best have an accredited ac specialist shop replace the condenser and any other damaged pipe work

Mar 09, 2015 | 2003 Pontiac Grand Am

1 Answer

Ac cooling insufficient


Sounds like not enough freon was put back in When you use a torch to heat the tubing a flake from the inside of the tube can travel to the capillary tubes in the evaporator plugging one or more of them. That would cause a very low suction pressure on the test gauges.

May 17, 2013 | Honda civic clutch set, compressor. a/c...

1 Answer

2002 taho location of orifice tube, ft and rear systems


I would check the low and high readings with a gauge set first.
Its possible the compressor has failed internally.
If the orifice is plugged up one of the lines should be cold where the freon gas is concentrated.
The fan clutch is working ok, right ?
I'm showing an orifice tube in the front and an expansion valve in the back, so its doubtful both would fail at the same time.

Jul 23, 2012 | Chevrolet Cars & Trucks

1 Answer

My Window unit cools real well in the morning. The air flow from the ac is 50 degrees, then by noon the temperature is 80 degrees and then it won't cool again. I am trying to cool an 8 x 35 ft....


When was the last time you cleaned the evaportor coil and condensor coil???? When its cool outside the condensor if its plugged with dirty can mantain the right condensor Head Pressure by useing the cool outside air when it has to run with 80 to 100 degree air it can't get the head pressure with in range to cool the freon. I would clean the condensor coil.......

Jun 19, 2011 | Friedrich ZStar ZQ10A Air Conditioner

1 Answer

Can I mix brands/tons when installing AC unit to existing coils?


First off - the 'rule of thumb' is 600' per ton of Air Conditioning. In other words your old unit is a 2 ton unit. So - 2 tons x 600' = 1200'. As you can see if you install the 2.5 ton unit - you will be installing a AC that 'could' cool a 1500 sq ft house (2.5 x 600' =1500 sq ft.). Slightly more than what you need; and the 3.5 ton unit is 'way to big,' (3.5 x 600' = 2100 sq ft.).

Note: fyi - many in the AC business will sometimes refer to tonnage in btu's, i.e. 1 ton = 12000 btu - hence a '2 ton unit' can also be referred to as a 24000 btu unit and vice versa.

So... from the above - you can easily see that "2 tons" of Air conditioning is what is required to cool the 'average' home of 1100 sq ft. "roughly speaking."

Note: it is always best to have a professional 'size' your cooling/heating needs.

One of your questions was could you 'mix tonnage?'

The answer is 'usually you don't mix the tonnage of your outside/inside units.' However, professionals sometimes do (mix the tonnage) in certain situations, and installing a 2.5 ton outside unit with an existing 2 ton inside unit is often done, however, there are some 'tech issues' here and - I would "again" recommend that you call a Service Tech to help you with the sizing/mixing of your cooling/heating needs.

hope this has helped

Jun 20, 2010 | Carrier 38CKC036 Air Conditioner

1 Answer

MOD on a window AC


The capillary tubes are your metering device, without those, and the length of the tubes are determined by the design of the unit and tonnage.
On bigger units we use expansion valves to do the same job,

Apr 04, 2010 | Heating & Cooling

1 Answer

AC not cooling during the day


Your AC cooling efficiency is low when he ambient temperature is high and naturally it cools well when the outside temperature drops.

Please remove the filter on the grill and try to clean it under the tap water and after removing all the dust fix it back to the unit. This would increase the cooling efficiency of the unit.

Your AC is also five years old. Please avoid frequent opening of doors or windows.

Ensure that the exhaust fan and the blower of your unit are functioning normal.

The technician might not have done a proper job in fixing the area where the refrigerant would have leaked out. Please check the refrigerant pressure to ensure that no further refrigerant leak has taken place. Or even servicing your unit he would have punchered the tubes resulting in very slow leak of refrigerant resulting in no cooling or less cooling. It takes around a month to feel the pinch of it and the refrigerant. One fine morning after sometime the unit will run and it would start throwing hot air instead of cool breeze!

Jul 13, 2009 | Heating & Cooling

1 Answer

Loss of spark on 2001 srx lost all three coils


1. Disconnect AC Magneto Coupler. (Located on right side of sled under the black 2" cooling line)
2. Connect meter. OHM x 1

White/Red - White/Green
189 - 231 OHM at 20 degree C (68 degrees F)

Charge Coil Resistance
White - White
.36 - .44 OHM 20 degree C (68 degrees F)

If out of spec replace.

Jan 27, 2009 | Sport & Outdoor - Others

1 Answer

1999 Kenmore side by side fridge not cooling


You're frosting up due to either: bad defrost timer/heater or low gas. I'm assuming that you completely defrosted the unit, that there are no open liquids inside and the door remained closed most of the time to remove the threat of excess moisture in the box.

Defrost timer issues:

The unit should 'rest' about 1-2 hours a day where you don't hear the compressor and the unit should try to melt the ice. It has a heater to do that. The timer or the heater or a connection could be bad.

More likely: you've got a low gas situation. The way to check is that the compressor should come on at some point. Check the larger tube. Is should get frosty and then clear off or stay wet. It might even dry off. If it remains frosty...you're low on gas. Depending on the type of gas you need...it may be R 12...they unit may be unrepairable by other than a licensed tech.

Jun 12, 2008 | Amana 22.6 cu. ft. Side-By-Side...

Not finding what you are looking for?
Dometic NDR 1062 Refrigerator Logo

Related Topics:

127 people viewed this question

Ask a Question

Usually answered in minutes!

Top Dometic Refrigerators Experts

John Tripp
John Tripp

Level 3 Expert

4654 Answers

4stevetaylor

Level 1 Expert

62 Answers

RV REFER LLC

Level 1 Expert

20 Answers

Are you a Dometic Refrigerator Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...