Question about LG Art Cool LA121CNP wall/window Air Conditioner

Open Question

My neo plasma LG error CH 67

Compessor start but fan dosent runs

Posted by Anonymous on

3 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 1 Answer

SOURCE: error ch 5

check all wiring and connections - ch 5 is a communication error between the indoor unit and the outdoor unit......

Posted on Dec 16, 2007

hvac1960
  • 2133 Answers

SOURCE: LG air conditioner 24awn error code message Ch 6

CH-06 REFERS Indoor unit coil sensor fault. Disconnect from PCB measure resistance. 10 kOhm at 10C and 4 kOhm at 30C. if not replace sensor. THANKS.

Posted on Dec 13, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I have a neo plasma lg 7kw will not heat LG Air conditioner


Make sure the setting on the remote is correct . Sun symbol for heating. Make sure the filters are clean. On heating, the indoor unit will 1/2 open the flap but the fan shouldn't start. The outdoor unit should start and if working properly, will be blowing cold air. The indoor unit will open the flap fully and the indoor fan will start once it gets hot then you should feel warm air. If the outdoor unit is blowing warmish air, I would say the reversing valve coil has failed or one of the indoor temp or pipe sensors are faulty. If a sensor fails, a "CH" error should appear on the display.

Mar 30, 2016 | LG Heating & Cooling

1 Answer

LG neo plasma error code


It means the lid is open OR it has a short circuit.

Jul 08, 2015 | LG Asmc183vm Neo Plasma Filter

1 Answer

Error code 67?


The indoor fan motor had blocked.

Feb 05, 2014 | LG LSN121HSV2 11,200 BTU 20 SEER Ductless...

1 Answer

Lg dehumidifier ch 67 error


Thanks for the post by Posted by Bill L on Jul 14, 2012.
I decided to take a chance and order the new Sensor assembly $20.50 and install it in my LG LD651EBL Dehumidifier which was giving me ch 67 errors. Wala, it worked, the error code is gone and the dehumidifier is now working perfectly! Thanks

Jul 14, 2012 | LG LD651EBL Dehumidifier

1 Answer

Error code 67


Error code 67 is an airflow problem. Either clogged filter or bad blower motor. Unplug unit remove bucket and feel for filter in front behind cover it drops down. Clean filter with water and reinsert. Plug unit in turn to "on", fan should begin to run, after 3-5 minutes compressor should start. If fan does not start it is bad and should be replaced.

Jul 07, 2012 | LG LHD65EBL Dehumidifier

2 Answers

LG dehumidifier LD451EGL with error code CH67


After cleaning the filter, i had to unplug the unit to clear the ch 67 error code before the unit would run again.

Apr 16, 2012 | LG Dehumidifiers

2 Answers

Error ch 5


check all wiring and connections - ch 5 is a communication error between the indoor unit and the outdoor unit......

Dec 09, 2007 | LG LSC183VMA Split System Air Conditioner

1 Answer

Lg invertor air con "neo plasma"


i have the same, only way to get goin is turn off at mains. ive now tried running on fan low .... got this tip from another problem and seems to work.
good luck

Nov 04, 2007 | Computers & Internet

Not finding what you are looking for?
LG Art Cool LA121CNP wall/window Air Conditioner Logo

Related Topics:

58 people viewed this question

Ask a Question

Usually answered in minutes!

Top LG Heating & Cooling Experts

Donni Steen

Level 3 Expert

659 Answers

Tim Whalen

Level 3 Expert

3072 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Are you a LG Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...