   Pilot light blows out about a minute after I turn the furnace on..tried 3 times, and every time, furnace runs for a minute or so, then blows out the pilot light. We just put a new roof on our trailer and had to extend the chimney about 4', could this be building somekinda back pressure?(doubt it). We also didn't properly seal the chimney right away and had some water leak down into the pipe. Any suggestions??  Thanks

Posted by on

  • Richard G. Carrillo Dec 29, 2007

    I have an Intertherm furnace in my mobile home. We recently had a new roof put on and the vent pipe to the furnace was extended to about 4'. The pilot light wouldn't stay lit, so I replaced the thermocouple. It would light, but once the furnace came on, it would blow itself out. So I replaced the gas valve and cleaned everything with air. It's doing the same thing.

×

Ad

10 Answers

  • Level 1:

    An expert who has achieved level 1.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 1 Answer

The blower on my furnace keeps going on and off when i turn the furnace on .ichanged the snapdiscs no change changed thermocoupler and therostat still no change whats my problem

Posted on Mar 27, 2010

Ad
  • Level 1:

    An expert who has achieved level 1.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 1 Answer

Check the  chimney  On mobile homes this is a 2 piece chimney and must be installed correctly  What may be happening is the flue gases are getting into the fresh air comming back to the furnace and  and this will smother the flame .

Posted on Oct 30, 2007

Ad
  • Level 1:

    An expert who has achieved level 1.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 1 Answer

My mother has a Intertherm MAC2460A furnace. It quits after running for maybe a day or two. by toggling the auto/fan switch it runs again. any ideas? Motor seems to be fine and I replaced the room thermostat

Posted on Jan 23, 2009

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 4,655 Answers

If the pilot light is the thermocouple type the thermocouple is bad and will need replaced. It's the little tube the flame/pilot keeps hot in order that the gas valve will open when the thermostat tells the gas valve to open and the large burner ignites. Hope this helps, Let me know, Thanks Sea Breeze

Posted on Oct 30, 2007

  • John Tripp
    John Tripp Oct 30, 2007

    Yes air blowing over the thermocouple can blow the flame out so check this too.

×

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

I have a mac 2254 series it constantly runs, any idea what
the problem may be

Posted on Oct 12, 2009

  • MIke M Sep 02, 2010

    some untis the blower fan will run constantly when the fuse is blown and, if thats not so look into the circuit board.

×

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

Intertherm furnace, just replaced blower. Now it will not shut off

Posted on Nov 07, 2009

  • Russell Sadowski
    Russell Sadowski Mar 25, 2014

    Does your furnace have 2 plugs? One black, one white. one is specifically for furnace the other is for summer air circulation

×

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that has over 10 points.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Expert
  • 36 Answers

Put a dial type Thermometer in a register farthest from the furnace. I lowered my temp by 2 degrees, by slowing the blower speed. If you have problems with the blower shutting off, before the thermostat set point, it may be the thermo overload built into the motor. I slowed the speed of my blower from High to Medium High. The heat went from Medium High to Medium Low. This created less heat in the motor, & let it run longer to keep the Temperture at the set point. If you have a dehumidifier, make sure it is not near the furnace intake, because they blow warm air, & the A/C unit will run longer.

Posted on Jul 10, 2010

  • Level 1:

    An expert who has achieved level 1.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 2 Answers

I replaced the new thermocouple and that was the problem. I've found out, hundreds of dollars later that just because it's a new thermocouple, right out of the package, doesn't mean it's good.

I replaced the new thermocouple with another new one and now my heater works fine. My cousin seems to think the length of the new vent had something to do with it too.

Posted on Oct 11, 2008

We had same problem the chimney wasn't connected properly when installed, once the repairman connected it problem went away.

Posted on Oct 11, 2008

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

Fan runs on heat not on cool

Posted on Oct 31, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

I HAVE A MODEL UFG-101AG-4 SERIAL # 800H2 INTERTHERM FORCED AIR FURNACE FOR MOBILE HOME OR TRAVEL TRAILER THAT I DONT KNOW WHATS WRONG WITH IT?


OK. Let me answer you, even if honestly I don't have any idea about an INTERTHERM FORCED AIR FURNACE. To get any answer, to a problem, you should describe your problem. Just telling that you don't know what's wrong with it is simply no enough information, even for a star expert in your INTERTHERM FORCED AIR FURNACE.

Jun 25, 2015 | Intertherm Heating & Cooling

1 Answer

I need an Owners Manual for Intertherm M7RL 060A BW


Unfortunantly In order to download the manual you have to fill out that you are a student HVAC professional at NORDYNE University Log In Register
Once you are in you select north american products.
Then select intertherm and click search products.
The Search will come up.
Select HVAC, Leave Select product type set to optional and type in the box below that M7RL. Click Search products.
Click the first Item on the list M7RL 95.1% AFUE Gas Furnace.
This will give you it all!

Be advised. If you are not a HVAC professional. Installing the furnace is not recommended. In order to get parts you will need to have a Contractors license or EPA Certification to purchase from the supply chains like Johnstone supply (the best place to get any part). Please be careful and think about the dangers of carbon monoxide, gas explosions and improper electrical hookups if you are attempting to do the repair yourself.

Hope this helps you
Jay

Nov 03, 2014 | Heating & Cooling

1 Answer

Where on internet can I find a diagram of the furnace listed below?


Google that number. Find manufacture, go to their site search customer support or contact us. Ask them for it.

Mar 05, 2014 | Intertherm E3EB-017H Furnace 17Kw 2

1 Answer

Pilot won't stay lit


as long as it is in the flame you should be fine

Dec 04, 2012 | Intertherm Gas Furnaces - M1GB-056-AA

1 Answer

Intertherm furnace will not ignite the board flashs four times


Hi, you will have a chart glued to a panel with a list of codes per flashes telling you what to check with 4 flashes. Read this and get back to me on what is is telling you.
Robert Horton

Oct 25, 2011 | Intertherm P3RA-048K Air Conditioner

1 Answer

Need a product manual for intertherm model p5rd-036k


http://www.nordyne.com/Literature/455a.pdf
and here ya go. check this web site for your manual.
Hope this is what you want.

Dec 26, 2009 | Intertherm P3RA-036K Air Conditioner

1 Answer

How do I remove the limit switch from my old furnace?


Sounds like you took a hit from a capacitor. That is the only thing that could Zap you if you are sure all power is off. Usually capacitors hold a charge if their is no resistor/ bleeder on it. Find your capacitor(s) round or oval with wires coming off the top. DISCONECT POWER TO UNIT. Short across the terminals on all capacitors with a screw driver to release charge. Do not touch metal part of screw driver while doing this. Then remove your wires form your limit with insulated insulated needle nose pliers.

Nov 02, 2009 | Intertherm P3RA-048K Air Conditioner

1 Answer

The Intertherm AC Model B3BV-030K-A is blowing warm air


If you don’t see any frost on the suction line or big line on the furnace
(that goes from the furnace to the outdoor unit) and the filter and coil are clean then you are probably low on refrigerant.

Apr 14, 2009 | Heating & Cooling

1 Answer

Where do the filters go on the Intertherm MGH055AB?


The filters on an Intertherm usually go on the inside of the front panel

Mar 06, 2009 | Intertherm P3RA-048K Air Conditioner

2 Answers

Intertherm heat pump blows hot then cold then hot


You may have a problem with a temperature safety system.  Before changing anything else, check to see if the unit is clean!!!  Dirt/dust can fool the safety system into an overtemperature status.  Inspect the heat coils for damage and dirt.  Gently clean.  

Nov 23, 2008 | Intertherm P3RA-048K Air Conditioner

Not finding what you are looking for?
Intertherm P3RA-048K Air Conditioner Logo

5,261 people viewed this question

Ask a Question

Usually answered in minutes!

Top Intertherm Heating & Cooling Experts

Dennis Boxerman

Level 3 Expert

1262 Answers

Bill Long

Level 3 Expert

588 Answers

john h

Level 3 Expert

16317 Answers

Are you an Intertherm Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...