Hi, im having a living nightmare with my logic combi 24 and since day 1 which was 3 and a half years ago it has always on regular occasions locked out and flashed L2. very rarely can i get it to restart again and if i do it only lasts an hour if that and locks out again. iv had more than 10 different plumbers come to it and even a new electorode been put in but despite them getting the boiler going its been a few hours later its back to square one lockout. these cheeky beggars then want paying as they claim there work is done as they got the boiler on and going when they were present. pure cheek if you ask me as a decent tradesmen wouldnt do or say that. what they needed to do was admit they couldnt fix the problem with their 15,20,25 years experience and just say that. please help i have 4 kids and were neth heat or hot water and cant be paying anymore dodgy plumbers when the jobs not getting done. thankyou

Posted by on

  • 2 more comments 
  • RJ Systems (Retired) Feb 12, 2014

    Hi Donna. I'm Roger. Sorry, I am not a plumber. I earned one of my Journeyman cards in the various heating trades. I don't know how to stay with you for sure but I"ll give it my best. Can you tell me what an L2 code means? There should be a list of the codes on a laminated card on the front panel or on the inside of the front panel. Your exact model and full model number will help also. I"ll need to look it up but will let you know when I get it. Thank you. Roger

  • RJ Systems (Retired) Feb 13, 2014

    I have the information on your system and think we can get started on your problem. Let me know when your ready to start. Roger

  • RJ Systems (Retired) Feb 14, 2014

    Hi Donna. I looked up your boiler. Your having Flame Failure trouble. There are a few things for you to look at and maybe adjust. Let me know if you still need help. I think we can get this fixed for you.

  • paulcarew Mar 11, 2017

    L2 is flame loss contact ideal

×

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Heating & Co... Master
  • 2,461 Answers

Ideal have there own tech helpline . you can also down load a manual for your comdi with fault codes .

Posted on Mar 11, 2017

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

  • 7 Answers

SOURCE: Combi bolier problem

either the h/w flow switch or diaphram reqs replacement or the secondary heat ex or (calorifier) is blocked and prevents the heat from leaving the biler to hget to he taps- the heat starts ok but backs up to the boiler very quickly causing it to shut down

Posted on Sep 18, 2008

  • 1 Answer

SOURCE: Grasslin Digital wall mounted timer programme setting instructions please

pdf file link, instructions will say it is for a topica500 also known as a logica 500.
Hope this helps.RoyG

Posted on Mar 09, 2009

  • 1 Answer

SOURCE: no hot water from combi boiler

i have a combie bolier when i turn the hot water taps on only cold water comes out central heating working fine can any one give some advise ?and can i fix it myself.

Posted on Mar 20, 2009

frcs68
  • 1605 Answers

SOURCE: I need user's manual for Danfoss Randall Thermostat TP4000

go to the following link.
download and print the user namual.
http://randall.danfoss.com/PCMPDF/40811v01.pdf

Posted on Apr 06, 2009

  • 744 Answers

SOURCE: need to set the timer!!!

Jonathan,

See this link:

http://www.glow-worm.co.uk/products/pdf/discontinued/boilers/CXI_range.pdf

Hope this helps!

Posted on Apr 27, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My ideal logic combi 30+ is saying ignition lockout and my radiatiors arent heating up as well as my water not turning hot. How can i fix this please?


Lockout is a safety feature. Usually a latching condition and needs to be investigated rather than blindly reset. (The Combi has a bit more intelligence.) With the ignition locked out, you can't hi-fire the boiler, so no hot water of either type. The 'L' should also show a code number - check your user manual (google) for more guidance.

I've had a lockout on a non-combi: it was caused by lack of circulation of central heating water through the boiler.... The system boiled and the trip tripped. The pump WAS running, but wear in a valve actuator resulted in the valve feedback saying valve open while it was physically shut.

Dec 31, 2016 | Water Water Heaters

1 Answer

Is there a manual for the Ideal Logic combi 30


Hi.

Please click on the link below to download the manual for your combo. The manual is in PDF format and covers different models:

Logic Combi Manual - Ideal Heating

Regards.

Ginko

Sep 14, 2011 | Heating & Cooling

2 Answers

MY IDEAL LOGIC 30 HAS FAULT CODE L2 ALMOST EVERY DAY SINCE INSTALATION DEC 2010


is boiler still under warranty?
normal warranty lasts at least 2 years
if so get ideal to send one of their engineers out
L2 relates to flame failure
either boiler has failed to ignite
or
boiler has not detected flame once lit

several causes

failure to ignite
ignition electrode/spark generator

failure to detect lit flame
detection electrode/detection lead

blocked condensate pipe
or defective condensate syphonic trap

you really need an engineer to check these components

Mar 16, 2011 | Heating & Cooling

1 Answer

Manual for ideal logic 30 combi boiler


Try with this:

SERVICEMANUALS @ COST www.mauritron.com Manuals at free download: homeappliance.manualsonline.com/manuals/.../lg_air_conditioner_product_list.html Helpful?

Dec 20, 2010 | Heating & Cooling

2 Answers

Manual for MAINE COMBI 30 ECO BOILER


Hi and welcome to FixYa. I am Kelly. I think this is your manual but if not let me know and I will do my best to find it for you:

http://www.burgeandgunson.co.uk/heating/Main_images/5119467_-_Main_Combi_Eco_Users_issue_01.pdf

Natural Gas

Main Combi 25 Eco

G.C.No 47 467 01

Main Combi 30 Eco
G.C.No 47 467 03

Thanks for choosing FixYa,
Kelly

Oct 21, 2010 | Heating & Cooling

1 Answer

I have an ideal standard he30 boiler instaledi have an ideal standard he30 boiler instaled about 6 weeks ago. the boiler keeps losing presure about half a bar every 2 days if i dont top it up it will trip...


Hi,
You have a problem that the installer does not know how to fix so they are just stringing you along hoping that you will give up and find some one else or forget about it..
You need to tell them to
1. fix the boiler correctly
2.take it back out and give you a new one at their expense
3. or tell them you will call another comapny to fix it and will give the bill to them to pay.
You did not get what you have paid for... do not pay them any money to come out and troubleshoot the boiler.
The boiler should work as the instructions say or someone did something wrong...
Sometimes it is best to call the boiler company and talk directly to their Tech. Support people.


I hope that this will help you to solve your problem!

Thanks for using Fixya!!

Heatman101

Dec 24, 2009 | Heating & Cooling

1 Answer

I have an ideal standard he30 boiler instaled about 6 weeks ago. the boiler keeps losing presure about half a bar every 2 days if i dont top it up it will trip the fuse on the fuse board acording to the...


All the combis I've come across merely fail to fire if the pressure is not up. not only do they not fire, nothing else works including the pump and in any event the pump should not overheat just on low pressure.
water loss - try turning off the valves on the flow & return pipes [3/4 inch ones] 1 valve per pipe . This will isolate the rest of the system - rads etc Note pressure over a time period. In this mode the hot water circuit will still work but do NOT use the heating circuit
1/2 bar over 2 days is not serious but it should be found
Once you have either mended the leak in the rest of the system or found there is not one, insist on a replacement boiler
In any event having looked at the reasons given for the fuse blowing, I would definitely get a replacement.
These problems should not happen on a new boiler
I list Worcester.-Ariston-GlowWorm-Ideal- and many others who would confirm this

Dec 24, 2009 | Water Heaters

2 Answers

Combi boiler problem


most have an overrun built in for a few minutes. if much longer have you got a room thermostat anywhere to turn down
If it never turns off check the switch which controls ON/TIMED/OFF and turn to timed or off. if it still continues on timed then it's the timer

Jan 22, 2009 | Whirlpool Aquatic Millennium VII -...

1 Answer

My aristion DIA 20-24 combi boiler keeps tripping the over heat thermostat button located under the main control panel maybe 5 times a day seems to be getting more frequent


hi,

just check your water supply of your aristion DIA 20-24 combi boiler if is in constant pressure. not properly circulated water supply can cause overheating.

and manuals can help us also in proper checking. at the link below please check this out if you don't have.

http://www.ariston.co.uk/products-select.php?t=0&id=0000000005


Nov 28, 2008 | Heating & Cooling

Not finding what you are looking for?
Heating & Cooling Logo

Related Topics:

82 people viewed this question

Ask a Question

Usually answered in minutes!

Top Heating & Cooling Experts

paulcarew

Level 3 Expert

2461 Answers

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Are you a Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...