Anonymous Posted on Feb 09, 2014

Pool motor runs slowly for a couple of seconds then trips.To restart one has to wait for truflex plate to click but same result when you try again.

Replaced melted capacitor with a25 was 30 before

2 Related Answers

Anonymous

  • 22 Answers
  • Posted on Jul 10, 2009

SOURCE: Proline 1.5 hp pump gets hot and trips breaker.

motor is locked up in the motor are two bearings they will rust if they are set up for a while.you can take the back off the motor and where the shaft goes thru the houseing take a pair of needle nose plires and try to free it up.

Ad

Anonymous

  • 111 Answers
  • Posted on Nov 19, 2012

SOURCE: replaced pool pump motor but breaker keeps tripping

Breakers are mechanical parts and can fail. If none of your components are causing the breaker to trip it's the breaker itself.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
2answers

Pentair pool heater keeps tripping breaker when i turn on

When you switch it on, watch the breaker trip. Does it slowly move to off? That is a lazy breaker and needs replacing. People use breakers as switches and they are not made for that, so they wear out.

If the breaker snaps straight to off, you have a short to earth. Look for water around the electrics particularly at the pump.

If you can't see anything obvious, call out a pool electrician to diagnose and fix.

There are other ideas on the link.

https://www.google.com/search?q=pentair+pool+heater+trips+breaker

..
2helpful
2answers

What would cause a FLYGT 3152 submersible communator pump to keep tripping at the breaker in the control panel

earth leakage is tripping the breaker from bad insulation or water in the motor or wires
Jun 19, 2017 • Pool & Spa
1helpful
1answer

Why does my aqua drive 1100 auto reset pool pump work in intervals of a few seconds.it goes on for a few seconds then stops and after a few minutes it goes on again

Check for restrictions causing the pump motor to be overworked.
Motor is overheating, the the Thermal Overload Switch senses that and will trip. Once the motor cools, it will restart.
0helpful
1answer

Why does my hydromate motor trip the breaker?

Drag on the Motor is increasing the HEAT, the HEAT is what is causing the trip. Your motor sounds like it is getting weak.
Jul 03, 2014 • Pool & Spa
0helpful
1answer

New ao smith pool pump motor keeps tripping out under load

check the breaker might be weak possibly from previous pump motor also if it was hooked up incorrectly at first might have done damage to motor windings
0helpful
1answer

I tried my Rule 1800 cover pump to get the spring water off. I plugged it in and it tripped the switch on the outlet. I reset and it ran for about 2 seconds and then quit. I waited a few minutes and...

I assume the device being tripped is a GFCI -- the pump has a short to ground. Most practical solution is to replace the pump. Don't try to run it from an un-protected outlet (no GFCI) -- it's dangerous.

Charlie
1helpful
1answer

Pump overheated and tripped the safety switch, it will restart for about 20 seconds after you turn it on but then trips off again. I'm thinking it could be the starter solinoid.. how can it diagnose the...

I am thinking the run capacitor is bad, if the motor has a centrifugal swith on the shaft under the motor cover, it could be sticking in the "start" position. This can be repaired with a non-conducting cleaner for the switch..
0helpful
1answer

Proline 1.5 hp pump gets hot and trips breaker.

motor is locked up in the motor are two bearings they will rust if they are set up for a while.you can take the back off the motor and where the shaft goes thru the houseing take a pair of needle nose plires and try to free it up.
1helpful
1answer

Overheats and trips off

internal thermal over loads in motor are working properly! how old is the motor? double check all vavles on the intake and discharge line to make sure that they are open? sounds like the pump is pushing against what is known as dead head pressure. obstruction in discharge line! if valves are ok you can take the jet covers off (the piece that helps direct flow of water) which will relieve some of the pressure should allow it to run without tripping tgermal overloads. if none of this works replace motor!!
Not finding what you are looking for?

49 views

Ask a Question

Usually answered in minutes!

Top Hayward Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1397 Answers

john h

Level 3 Expert

29494 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Hayward Pool and Spa Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...