The humidifier has been working fine but turned it on a couple days ago, lights came on but no fan, no mist. Recently cleaned and put in new filter and it was working without any issues. Tanks are filled with water, unit is sitting on level floor. I unplugged it, turned it off for a day, tried higher setting...no luck. All the lights come on. Thanks
Check the thermo protector fuse at the bottom near the heating pad. The fuse must not be open circuit. If it is, replace it. You can order the fuse for $1 from eBay or Amazon. Good luck!
"Take the humidistat out of the humidifier and look for the 3 slits below the restart button, take a hair dryer and send some warm air into those slits for 5 minutes. That usually recalibrates the humidifier."
Testimonial: "fiantella...can you please explain to me how to remove the humidstat. Do I have to unscrew parts from inside the motor caseing or can it be pried without damage from the top? thanks"
SOURCE: Fan works, but no mist and water isn't going away
Turn on furnace and urn up humidistst to call for it. Tube from solenid to the filter should have water running if water is up to the valve and solinoid is opening . It should be warm to your touch., Using an ohm meter you can sheck the coil it shuold have continuity.
SOURCE: Honeywell HCM-305T Spits droplets rather than creating a mist.
this has nothing to do with any sort of nozzle as there isn't one on this device. As Skybum said, the "moat" overflows into the fan and then gets spit out as the fan turns. The device is wonderful at saturating floors but unfortunately not the air!
This is also not a consistent event. The humidifier will work for some time and then all of a sudden I wake up with a soaking wet floor.
I’m happy to assist further over the phone at https://www.6ya.com/expert/jason_ee8f979baffc115f
947 views
Usually answered in minutes!
sorry I posted this in the wrong place: "fiantella...can you please explain to me how to remove the humidstat. Do I have to unscrew parts from inside the motor caseing or can it be pried without damage from the top? thanks"
Remove side tanks. Remove casing (tower). No need to unscrew aything, just lift it. You swill see the 3 slots underneath the restart button. Blow it with a hair dryer for 5 minutes. The green light should turn on.
Cas Gabriel, Remember... This applies to Clairion DA-1030.
fiantella mine is a Honeywell Quietcare HCM 6009 totally different from the Clairon and there is no reset button on this model.
Check the thermo protector fuse at the bottom near the heating pad. The fuse must not be open circuit. If it is, replace it. You can order the fuse for $1 from eBay or Amazon. Good luck!
×