Question about GE Refrigerators

1 Answer

How do I force a defrost on a ge sxs gss20iepcww It is not a touch pad control ref. It has 2 knobs

Posted by on

1 Answer

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 2 Answers

On all ge electronic models produced since 2000 the main power lead to the main board can be jumped to test either defrost or compressor operation.to do this unplug the unit and locate the 3 wire plug (usually blue in color) .unplug the harness from the board and create a jumper wire to by pass the board.the terminals on the board will be identified as line,compressor and heater.to put unit in defrost install jumper between line and htr or def .this will ck the defrost sys.once unit is plugged in with jumper in place the heater will come on.if the heater does not come on look for a defective heater or defrost t/stat.hope this helps.

Posted on Jun 04, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Set clock on ge profile gas range


Didn't give a model number, but try the following:

For a mechanical clock, push the center knob in and turn the clock hands to the correct time. (If the Minute Timer pointer should move also, let the knob out, turn the Timer pointer to OFF.)

For a digital clock, push in the center knob of the Minute Timer and turn Knob in either direction to set the Digital Clock numerals to the correct time.

For an electronic clock, touch the Clock pad. Touch the number pad. Touch the start pad until the time of day shows in the display. Note: On double wall ovens, you can only set the Timer for one oven.

(From the GE website)

Nov 06, 2016 | GE Kitchen Ranges

1 Answer

Would like specifications to JVM1850SM2SS


  • 1.8 CF Oven Cavity
  • Electronic Touch Controls
  • 950 Watts
  • Display On/Off Yes (option pad)
  • Add 30 Seconds Instant-On
  • Cooking System CircuWave┬«
  • Defrost - Auto / Time / 1 lb. Quick Defrost
  • Delay Start
  • Express Cook Instant-on 1-6 minutes
  • Instant On Controls
  • Micro / Time Cook I & II
  • 10 Power Levels
  • Wire Oven Rack
  • Cooktop Lighting - Bright/Night/Off
  • Demo Mode
  • Interior Oven Light - Halogen
  • Night Light (option pad)
  • Child Lockout
  • Easy Mount Installation
  • Exhaust Fan 3 Speed Plus Boost (315 CFM)
  • Cooking Complete Reminder
  • Timer (On/Off)
  • Reminder (24 hr)
  • Sound Volume Control - 4 levels
  • Sensor Controls
  • Beverage Instant-On
  • Popcorn Instant-on
  • Potatoes Instant-on
  • Reheat Instant-On
  • Sensor Controls
  • Vegetables Instant-on, 3 pads (canned, frzn, fresh)
  • SmartControl System
  • Clock Plus AM/PM pad
  • Concurrent Programming
  • Custom Pad
  • Electronic Scrolling Digital Display - 2 line
  • Help Pad
  • Variable Scroll Speed - 5 Speeds (Options Pad)
  • 14.25 " Turntable - Glass Recessed
  • Turntable On / Off
  • 2 Wire Oven Racks; 2 Positions
  • Recirculating Charcoal Filter Kit JX81B

Dec 15, 2014 | GE Microwave Ovens

1 Answer

Where is defrost timer location on fridgedaire mod # ED25DQXVN00


Your mechanical defrost clock timer is located in the control panel where the rotary knobs are for the ED25 model given which is a Whirlpool SxS, For the Frigidaire Mod FRS, your defrost control will most likely be located in the long housing running down the center wall (front to back) of the fridge near the outlet vent, this is an electronic adaptive defrost control. Pleazer Appliance...

Apr 18, 2014 | Frigidaire FRS26KR4A Side by Side...

1 Answer

GE Monogram ZIDS240PSS Double Drawer Refrigerator freezes items stored. Temp indicator as low as 19 degress F. Turned unit off and back on using touch pad. Touch pad instructions were ignored without...


Please VOTE FOR ME AND GIVE ME YOUR TESTIMONIAL IF POSSIBLE, IF THIS WAS HELPFUL
ITWILL BE MUCH APPRECIATED.
The cold control needs replacing. Thats the knob with the numbers that turn the Ref OFF and ON.
What I do is call my local Appliance Parts Store with my model no. They are extremely helpful .
Get freezer and ref thermometer. Ref is probably too cold.
Freezer should be 0 to 10 degrees. Ref 33 to 35
If you need more help, Go here:

http://www.applianceaid.com/procedures.html

I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article

http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically

MORE TIPS AND TRICKS:
-----------------------------------------------------------------------------------------------------
STOP PAYING FOR EXPENSIVE WATER FILTERS FOR YOUR REF. DO THIS====
http://www.fixya.com/support/r9962087-stop_paying_high_price_refrigerator
-------------------------------------------------------------------------------------------------------
WATER SPLASHING IN FREEZER AT ICEMAKER
THE FILL TUBE IN BACK OF REFRIGERATOR CAN SLIP
AGAINST THE FILL RESERVOIR CAUSING A PARTIAL BLOCKAGE
OR BECOME CLOGGED WITH ICE.
REMOVE THE ICEMAKER AND INSPECT THE FILL TUBE.
RUN WATER IN TUBE TO ELININATE BLOCKAGE AND CHECK
TEMP IN FREEZER. IF TEMP IS BELOW 0 DEGREES, THATS
OVERKILL AND USUALLY A WASTE OF ELECTRICITY TO KEEP IT THAT COLD, NOT TO MENTION THE FILL TUBE FREEZING UP
----------------------------------------------------------------------------------------------------------------------
Thanks for using fixya
Leo Ponder
imufo2
Please VOTE FOR ME AND GIVE ME YOUR TESTIMONIAL IF POSSIBLE, IF THIS WAS HELPFUL
ITWILL BE MUCH APPRECIATED.

Sep 09, 2011 | GE Monogram ZIDS240PSS Double Drawer...

2 Answers

My freezer will not go into defrost. Has new strips, and control board. Its an HSS22GFTAWW. Is there a way to force it into defrost?


NOTE: This
is a multi-solution answer since I don't have all the tech from your question to pinpoint your problem
But the solution is in here generically, if you read and study the solutions very,very carefully.
First I would check cold control. Thats where you turn it off, if your temp is not warm. it can
be defective and not shutting off. If your temp is warm proceed with the following.
I would check the fan in the freezer. Listen to see if it is running
It moves air to the ref from the freezer
Then check to see if FREEZER CONTROL is turned WARMER WHICH MAKES THE REF COLDER AND VICE-VERSA. SEE?
The ref. temp should be about 33-35
The Freezer temp should be 0 to 10 Any thing below these temps is overkill and a waste of elect
The higher the number you turn it up to is the coldest
Also this might be a common Defrost problem, Ice
is not being melted by the defrost system.The fan can't blow through the coils into the fridge.
Take out back panel of freezer to check for ice buildup. The coils should be clean.
There are three components to a defrost system- a heater,heater thermostat, and a timer unless you have a defrost electronic card.
Its best handled by a Technician but you could possibly do it by taking your model number to the nearest appliance parts store and asking for the parts. They are mostly located in freezer ,behind back panel on freezer coils.except the card which is usually located in ref The parts store will have info
Also check fan undernearh Ref in the rear
Clean condenser coils underneath
Make sure back cover is on the fridge. Some take them off and throw them away.
make one out of cardboard if its gone, using the holes of the old one.
.I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article

http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically

MORE TIPS AND TRICKS:
-----------------------------------------------------------------------------------------------------
STOP PAYING FOR EXPENSIVE WATER FILTERS FOR YOUR REF. DO THIS====
http://www.fixya.com/support/r9962087-stop_paying_high_price_refrigerator
-------------------------------------------------------------------------------------------------------
WATER SPLASHING IN FREEZER AT ICEMAKER
THE FILL TUBE IN BACK OF REFRIGERATOR CAN SLIP
AGAINST THE FILL RESERVOIR CAUSING A PARTIAL BLOCKAGE
OR BECOME CLOGGED WITH ICE.
REMOVE THE ICEMAKER AND INSPECT THE FILL TUBE.
RUN WATER IN TUBE TO ELININATE BLOCKAGE AND CHECK
TEMP IN FREEZER. IF TEMP IS BELOW 0 DEGREES, THATS
OVERKILL AND USUALLY A WASTE OF ELECTRICITY TO KEEP IT THAT COLD, NOT TO MENTION THE FILL TUBE FREEZING UP
----------------------------------------------------------------------------------------------------------------------
Thanks for using fixya
Leo Ponder
imufo2
Please VOTE FOR ME AND GIVE ME YOUR TESTIMONIAL IF POSSIBLE, IF THIS WAS HELPFUL
ITWILL BE MUCH APPRECIATED.


NOTE: This
is a multi-solution answer since I don't have all the tech from your question to pinpoint your problem
But the solution is in here generically, if you read and study the solutions very,very carefully.
Check Temp inside freezer. It has to be down to about 10 or 15 degrees
This can cause slow ice making if its too high even tho its freezing everything else at 25 degrees
See if water is in icemaker.
Pour water in Ice Maker and wait to see if it ejects.
If it ejects thenyou need to replace water valve in rear bottom of fridge(Its the part that
attaches to water line out of wall)
If it doesn't eject then it is a faulty Ice Maker.
If its leaking or no water at icemaker or door either one, then the valve at the rear bottom of ref needs replacing
First I would check the fan in the freezer. Listen to see if it is running
It moves air to the ref from the freezer
Then check to see if freezer control is turned WARMER, which makes the Ref. colder
Also if it is getting drinking water to the door but not to the icemaker (or vice versa) Then you need to replace
the water valve at the bottom rear of the fridge. It is a double valve and one side is not working
Also this might be a common Defrost problem, Ice
is not being melted by the defrost system.The fan can't blow through the coils into the fridge.
Take out back panel of freezer to check for ice buildup. The coils should be clean.
There are three components to a defrost system- a heater,heater thermostat, and a timer unless you have a defrost electronic card.
Its best handled by a Technician but you could possibly do it by taking your model number to the nearest appliance parts store and asking for the parts. They are mostly located in freezer ,behind back panel on freezer coils.except the card which is usually located in ref The parts store will have info
Also check fan undernearh Ref in the rear
Clean condenser coils underneath
.I'm including my article on Refrigerator Repair for your help and convenience.;
Please click or copy and paste into browser for Article
http://www.fixya.com/support/r5816737-fix_refrigerator_psychologically
Thanks for using fixya
Leo Ponder
imufo2
PLEASE GIVE A TESTIMONIAL AND VOTE FOUR THUMBS UP IF THIS WAS HELPFUL

Aug 13, 2011 | Refrigerators

1 Answer

How to remove defrost timer


need complete model # to give correct help but most kenmore sxs ref / the defrost timer is located in the control panel . two screws to remove an un plug it .. reverse to install .. some older models are locaded behind the toe grill . same two screws.. mm

Oct 23, 2010 | Kenmore 52282 / 52284 Side by Side...

1 Answer

Test to see if circuit board is okay


From Appliance Aid.com

WHY Force the Arctica to Defrost if it Don�t Want to? Don't bother using the self-diagnostics feature to force a defrost cycle. On some models � those with control knobs - which technically are not Arctica models (Arctica models have plastic liners with touch pads � Standard GE electronic models with metal liners have knobs) servicers would have to invest in parts to build a �test� control panel, complete with touch pads and digital displays, to achieve this (self-diagnostics) function. Instead, save both time and money by following this helpful Arctica Tip: If a frosted evaporator or a �frost block� is apparent, initiating a defrost cycle may not reveal anything helpful anyway. First, disconnect power and then simply check the resistance across the defrost heater and bimetal circuit at the main board located at the backside. The two associated wires at the main board are almost always BLUE and ORANGE. The heater/bimetal circuit should normally read around 30 ohms roughly. Next, check the evaporator thermister at the main board between thermister input terminals J1-4 (Blue/White) and J1-5 (Blue) to determine that its resistance is greater than 1.2k ohms but not more than 166.8k ohms depending on its ambient temperature. If thermister resistance falls within this range according to temperature (Approximately: 6k ohms at 70�F � 16.3k ohms at 32�F � 51k ohms at 0�F) and the heater/bimetal circuit is diagnosed as good, then replace the main board.

Apr 30, 2009 | Refrigerators

1 Answer

Ge profile buttom freezer cold refrigerator hot


First, I think it’s important to know that the Ref side has no cooling coils, it’s basically a box and the cold air in the freezer is blown over by a fan through a channel into the Ref side. This channel has a door which regulates how much cold air goes through. You probably have two control knobs in the Ref side, one controls the temp with numbers 1-9, 9 being the coldest. This temp control tells the compressor how long to run. The other control is for that little door and it may have letters A-E, E being the coldest. If you set it on E (coldest) then this will close that little door and keep most the cold air in the freezer.

Now, why is that cold air not getting over to the Ref side?
1. The little door is not open.
check your control setting. You should be able to feel air coming through the channel on the Ref side.

2. The fan in the freezer is not working.
You can hear this fan running when you open the freezer.

3. The coils on the freezer side are clogged with ice which won't let the fan circulate the air over to the Ref side.
This is a failure of the defrost system.

Dec 17, 2008 | GE Profile Arctica Stainless Steel Top...

2 Answers

Fridge running but not staying cold


you have a defrost problem, if SxS ref. most likely bad defrost heaters. They are behind interior back wall. Sounds like you have a GE.

Jan 05, 2008 | Refrigerators

Not finding what you are looking for?
Refrigerators Logo

Related Topics:

259 people viewed this question

Ask a Question

Usually answered in minutes!

Top Refrigerators Experts

Sal DeAngelo

Level 3 Expert

2122 Answers

Lawrence Oravetz

Level 3 Expert

9587 Answers

okcchemist

Level 1 Expert

17 Answers

Are you a Refrigerator Expert? Answer questions, earn points and help others