Question about Kenmore AC2044-1 Air Purifier

1 Answer

Clean cell now flashes after 20 minutes

I have the same problem... it says clean cell now after it runs for 20 minutes

Posted by on

1 Answer

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 2 Answers

The previous suggestion helped me because as I was examining the cell for debris I noticed markings for "Top" and "Bottom" inscribed on the four corners of the front of the cell that I had never noticed before. After cleaning I had installed the cell upside down. It would work for 20 minutes and then shut off. The rounded thingies on the bottom of the cell are contacts which should touch the little springies on the bottom of the housing.

Posted on Jun 28, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

A red light flashing with clean filter


bad connection on plates or wires that run along the front of the plates in the cell. If you hear snapping or arcing then its the plates shorting out, look for bent plates and broken wires or loose sagging wires.

Aug 01, 2014 | Oreck XL Professional Air Purifier

1 Answer

We have model 11502 air purifier. Recently turned it on and it ran for a few minutes and then stopped. Motor sounded fine- no squealing, didn't slow down before it went off- just stopped like it was...


Yes there is a thermal cutoff that will shut the motor off for a period of time to protect it from getting to hot. If this is what happened after 20-30 mins. the motor should come back on and run again. If it does I would try to clean motor as best I could using a soft brush, vacumn, and blow out with air if possible. Clean fan of f as best you can to help motor run cooler.Hope this helps.Thank you

Jan 05, 2011 | Honeywell Air Purifiers

1 Answer

How do I clean the Oreck Air 7


Hi There,

Here's how you can clean the machine, and I have copied the link to the owners manual below for your convenience.

Cleaning
The Cabinet
You can clean the air purifier cabinet with mild, non-abrasive cleanser and a
soft cloth. IMPORTANT: Unplug the unit from its electrical power source.
Do not spray cleansers or furniture polish into the louver or grill areas.

Collector Cell
Indicator light is green under normal operation and flashes red
when the cell requires cleaning. To clean, proceed as follows:
The red "WASH CELL" light will flash or illuminate when it is
time to clean your cell. However, it is recommended that every four to
eight weeks or if snapping sounds become frequent, clean your
electronic air purifier. Your electronic air purifier is still filtering the air
when the red light illuminates. Cleaning your electronic air purifier is a
snap too... and a must for efficient operation.
1. Turn the unit off and unplug it from the electric power source. If wall
mounted, remove unit from wall.
2. Remove front grill by unscrewing the retainer screw under the grill on
the cabinet bottom. (fig. 1)
3251a7e.jpg
3. Pull the cell out of the cabinet by using the two small handles on the
front of the cell. (fig. 2)

4. Snap off the charcoal odor absorber from the back of the cell. Change
as necessary for continued odor removal. (fig. 3)
5. Slide off pre-filter. This can be cleaned with the cell and reused. (fig. 4)
NOTE: Handle the electronic cell with care. Damaged metal plates
and/or broken wires will cause the air purifier to malfunction. (Do
not wash charcoal odor absorber; it is disposable.)
Cleaning with Assail-A-Cell® Cell Cleaner:
6. Using Assail-A-Cell® Cleaner, thoroughly saturate the cell and prefilter.
Be sure to spray between each cell plate and cover every
surface. Allow product to soak for a few minutes, not allowing it to dry.
Rinse thoroughly with water. For extremely heavy deposits, repeat the
process.
IMPORTANT: Dry the collection cell thoroughly outside of the
air purifier before reinstalling it into the air purifier. Ensure
that all areas including corners and areas that may trap
water are dry before reinstalling into the air purifier. DO NOT
place a wet or damp collection cell in the air purifiereff1848.jpg
4. Snap off the charcoal odor absorber from the back of the cell. Change
as necessary for continued odor removal. (fig. 3)


e3ca384.jpg
5. Slide off pre-filter. This can be cleaned with the cell and reused. (fig. 4)


0781c8d.jpg
NOTE: Handle the electronic cell with care. Damaged metal plates
and/or broken wires will cause the air purifier to malfunction. (Do
not wash charcoal odor absorber; it is disposable.)
Cleaning with Assail-A-Cell® Cell Cleaner:
6. Using Assail-A-Cell® Cleaner, thoroughly saturate the cell and prefilter.
Be sure to spray between each cell plate and cover every
surface. Allow product to soak for a few minutes, not allowing it to dry.
Rinse thoroughly with water. For extremely heavy deposits, repeat the
process.
IMPORTANT: Dry the collection cell thoroughly outside of the
air purifier before reinstalling it into the air purifier. Ensure
that all areas including corners and areas that may trap
water are dry before reinstalling into the air purifier. DO NOT
place a wet or damp collection cell in the air purifier.

Here's the link to the owners manual for your Oreck Air 7:
http://www.oreck.com/includes/customer-service/owners-guides/pdfs/3323-3018-AIR7-Rev-H.pdf

I hope this was helpful to you. If this helped, please be kind and rate the repair, or leave feedback for me. Thank you,

Chris Jones
GoVacuum.com

May 01, 2010 | Oreck Super Air 7 Air Purifier

1 Answer

I do not know how to clean it. It is called Fresh


The Fresh Air has a reminder on the LCD to Perform Cleaning. This reminder will display if the purifier runs for 30 days. When this reminder is displayed perform the following steps to clean your purifier.

1. Cleaning the Case:

Wipe the unit with a soft cloth dampened with water. Do not use chemicals or solvents. Vacuum the front and rear grills to remove any lint buildup.

2. To clean the lint screen, RCI cell and purification plate:

3. To remove the back cover:

Remove the plug from the back of the unit. Unscrew the screw above the plug socket on the back cover. To remove the back cover, press the back sides of the back cover to unlatch and tilt the bottom of the back cover to remove.

4. To remove the rear lint screen:

Remove the two thumbscrews holding the top of the lint screen. Remove the lint screen by pulling back the top of the screen, then lift it up and out.

5. Removing the RCI cell:

Remove the RCI cell connector by pressing the connector locking tabs. Pull the connector straight out to unplug.
Remove the RCI cell by removing the two thumbscrews. Slide the RCI cell down and out of the unit.

6. Cleaning the RCI Cell:

Remove the RCI cell and carefully vacuum accumulated lint. Do not wash the RCI cell. Damage from water may result.

7. Rear lint screen cleaning:

You have two options

  1. When visibly dirty, simply remove the rear lint screen from the unit and with a duster attachment on a vacuum, remove the heavy particulate.
  2. In addition to step 1, the filter can be washed with hot water (do not use soap). Allow to dry prior to reinstalling. Replace if damaged.

8. Cleaning the Purifier Plate:

Remove the plate from the card cage by grasping the middle edge nearest to you, and slowly pull it straight out. Clean with mixture of one part water and one part ammonia. Place plate and ammonia mixture in a dish and allow it to soak for no more than 10 minutes. Remove plate and scrub with a toothbrush. Rinse thoroughly and air dry for 24 hours or use a blow dryer to dry thoroughly.

After all parts have been cleaned and are thoroughly dry, reinstall components in reverse order. Turn the purifier on, and on the key pad, press the reminder Reset button to clear the Perform Cleaning message.

If this has been helpful, please rate this solution. Thanks

Jan 28, 2010 | Ecoquest Fresh Air Living Air Purifier

1 Answer

How do I clean my EcoQuest Breeze?


The purifier should be cleaned about once a month and you should do the following:
  1. Unplug the Breeze before cleaning.
  2. Wipe the Breeze with a soft cloth dampened with water, vacuum the front grill to remove any lint buildup.
  3. Cleaning the rear lint screen - You can either vacuum the filter or you can wash in hot water. Allow to dry before reinstalling the lint screen. Do not use soap, it will damage the carbon material in the lint screen.
  4. Remove the purifier plate from the purifier and soak in 1 part amonia and 1 part water solution for 10-20 minutes. Gently scrub the metal grid on the plate with a toothbrush and rinse with water. Clean the metal contacts with the same solution. Allow the plate to dry overnight or use a hair dryer to dry throughly.

Dec 07, 2009 | Ecoquest Breeze AT Living Air Purifier

1 Answer

AC2044-1


Unit likely had large partical like dog or cat hair cross over cell, Unlplug and remove pre-filter & cell.

The unit has a timer that knows when power has been removed & front grille has been taken off by 2 micro switches in back of front grille that is connected to the units control board.

While you are there remove pre-filter & Cell, if ok and no debris is found & theres no need to wash, wait 10 to 15 minutes replace all & plug back in.

You should see the LED display flashing Clean Cell & Cell button flashing, hold Cell button in at least 3 seconds this may take longer to reset. Unit should turn back on.

This condition has happened to my 2 units on occasion even though I had washed the cell only a week or two previously.

The unit will turn off if a cell overload is detected by way of large static discharge. If I know the cell is clean, I just unplug the unit & take the front grille off for 15 minutes then & replace it plug back in & reset & all goes back to normal operation.








.

Apr 22, 2008 | Kenmore AC2044-1 Air Purifier

2 Answers

Kenmore ac2044-1 shuts off


Take Cell out and examine closely with flashlight for debris and bent aluminum cell plates or ionizing wires.

Make sure all plates are more or less clear of one an other with fairly even spacing between them and no kinks on their edges.

If any are to close together it will cause a cell overload that will cause the Clean Cell to display and or completely turn unit off all together.









.

Mar 28, 2008 | Kenmore AC2044-1 Air Purifier

1 Answer

Kenmore AC2044-1 question ASAP!


If it says "Clean Cell Now" and it is a new machine, it is broken. I have six, yes six, of this model. They are all new and you shouldn't have to clean the filter/cells for a few months.

The way to clean is:

  1. Unplug
  2. remove the white cover
  3. remove the prefilter. Good time to clean the prefilter by removing the 2 retention clips and gently swing the prefilter outward. Clean or groom it with a vacuum. Use the upholstery brush. wash the prefilter in warm, soapy water. No Chlorine! Rinse clean with regular water. Wipe with a paper towel and let dry completely. It is okay to gently use a hair blower to speed up the drying process.
  4. Onto the Cell.
  5. The cell can be washed one of two ways. Either in a hot tub of water or in a dishwasher.
  6. Wear gloves to protect your hands. Never touch the fins or wires. It will ruin them and cut you up. Use the two handles.
  7. Use hot water and dish detergent.
  8. No chlorine and no abrasives.
  9. Soak for 10 minutes, then dip a couple of times to remove stuck dust/dirt/schmutz.
  10. Rinse with clean water.
  11. Allow to dry
  12. Allow to dry
  13. Allow to dry
  14. Okay to use a hair dryer to speed up process.
  15. Reinstall
  16. Power up
  17. Press and hold CHECK button for 3 secs to reset.

Thanks.

Jan 10, 2008 | Kenmore AC2044-1 Air Purifier

Not finding what you are looking for?
Kenmore AC2044-1 Air Purifier Logo

Related Topics:

357 people viewed this question

Ask a Question

Usually answered in minutes!

Top Kenmore Air Purifiers Experts

fordexpert

Level 3 Expert

5495 Answers

kakima

Level 3 Expert

102366 Answers

Michael Youngman
Michael Youngman

Level 2 Expert

156 Answers

Are you a Kenmore Air Purifier Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides