Question about Hayward 250kbtu Ng Pool Heater - Inground

1 Answer

Pilot light is lit, but heater will not fire

Just started up the pool, got the pilot lit but the heater will not fire, it is an h250 about 10 years old. Help.

Posted by on

  • Anonymous Mar 12, 2014

    replace pilot generator pilot is lit but bureners do not fire

×

Ad

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Master
  • 864 Answers

Make sure thermostat is set higher than water temperature. Make sure pump is running and water is flowing through unit. If gas valve is not opening then flame sensor or gas valve is bad.

Posted on Jun 02, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
New users get to try the service completely Free afterwhich it costs $6 per call and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

My laar hot shot natural gas pool heater pilot says lit but wont fire any more replaced pilot generator pilot that whole unit nice pilot but wont fire


problem isnt with the pilot generator. you have either an open safety withing circuit, lose wiring connection, or tstat issue

Aug 17, 2013 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

Every year I have a problem getting it to light. The pilot is lit but the heater will not turn on. It is 8 years old and I have been having trouble with it since day one. My pool guy comes out fires it up...


First, check the gas valve and make sure the valve in all the way to "on" not "pilot".After shutting to off for the winter, and not turning the valve all the way on start up could be it. If that is ok, check/replace the pilot generator next to the pilot lite. One question. Does the pilot go out soon after calling for heat? Next, if you have it on "spa" or "pool" on the temperature adjusting module, try the other setting. eg. If it is on "pool", switch the knob to "spa" and adjust the temperature.

Jun 05, 2010 | Teledyne Laars Laars Lite 2 Pool Heater...

1 Answer

Pilot light is lit but the heater won't fire


it's possible there is a blockage in one of the lines---those tubes are a very popular place for spiders to build a nest. check especially where you see curves in any of the tubes

May 11, 2010 | Hayward 2001 Series Millivolt Gas Pool...

1 Answer

Pilot lit clicking noise no burner


make sure knob on gas valve(inside heater)is turned to on position.3/4" should be fine as long as heater is not larger than than 175,000 btu

Jul 14, 2009 | Jandy Lite 2 Natural Gas Pilot Light...

1 Answer

Pool heater pilot works but no heater


make sure filter is clean, make sure filter is at 10-18 psi , also post if electronic or millivolt heater

Jun 16, 2009 | Pool & Spa

1 Answer

Have a Triton Millivolt pool heater pilot is lit and nothing!!


Low out put voltage from the pilot generator and/or an open circuit in the control circuit...the most common is a bad pressure switch (dirty filters can hamper pressure switch operation).

Jun 08, 2009 | Pentair PUREX MINIMAX HEATER; THERMOSTAT,...

1 Answer

Pilot did not stay lit,replace gas valve , pilot stays lit,but now it won't fire up. Jumped the TH terminals and it shut off the pilot light.thermostat is set highier than the water temp.Jump all ths...


Your problem is the pilot generator where the flame is by the burners. This needs to be repalced. That is what is causing the pilot to go out and not start. It is a flame sensor and also tells the gas valve when to release more or less gas.

May 28, 2009 | Hayward H Series Pool & Spa Heater 400k...

2 Answers

Rheem Pool Heater Clicks


see if gas is on if ok check to see if cobwebs if ok see if voltage to gas valve when cycling

May 24, 2009 | Solar Rheem Gas Fired Pool & Spa Heater...

Not finding what you are looking for?
Hayward 250kbtu Ng Pool Heater - Inground Logo

Related Topics:

775 people viewed this question

Ask a Question

Usually answered in minutes!

Top Hayward Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1343 Answers

Bill Jordan

Level 2 Expert

372 Answers

john h

Level 3 Expert

12650 Answers

Are you a Hayward Pool and Spa Expert? Answer questions, earn points and help others