Question about Ecoquest Living Air Classic Air Purifier

Open Question

Alpine / eqoquest repair schematic

Thanks for your time in advance.. do you know where to find the schmatics for these xl15's? I have around 6 of them that are broken that I want to fix. kevin@baisley.net i need a schematic for living air x 15

Posted by on

6 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Saigua
  • 981 Answers

SOURCE: Alpine Air Living Air XL15 not producing Ozone or Deodorizing. New plates

Confirm that the appropriate sections of the circuitry are powered up and drawing power; check the interlock switch action; toss it back to the maker because the Hi-V transformer or ladder circuit or sense or hold caps were (if testing proves) never quite functional.

Posted on Jun 23, 2008

  • 80 Answers

SOURCE: I have an Alpine Living Air XL15 which doesn't

The plates should not glow, but on High, you should hear a buzzing sound. But, you should also smell the ozone. I've only worked on two, but the reason they both didn't work was that the connectors on the wires leading to the plates were corroded beyond use. The top connector was the worst. Cutting them off and installing new ones solved the problem. Also, when you clean it, always clean the contacts where they touch the plates with alcohol. Look at the plates to see if they have more than one spot of glue around the center of the plate. (both sides) If so, they will be less noisy than older ones. Hint - Replace the plates when the glue on them turns dark brown.

Posted on Apr 04, 2009

  • 3 Answers

SOURCE: Have a Living Air XL15 > everything works motor, fan, BUT .....

look through the front grill while its "on" you should see a glow from a neon lamp inside. If its not on chances are the circuit card is dead (should have about 350VDC plate voltage).
I have a used but good board if anyone needs one.
dale.gilchrist@gmail.com

Posted on Jul 02, 2009

  • 18 Answers

SOURCE: Alpine Living Air XL15 owners manual

those can be found online

Posted on Oct 27, 2009

  • 74 Answers

SOURCE: is there an online owner's manual for alpine

http://www.ecoquestintl.com/support/US50300_Living_Air_Owners_Manual.pdf

Posted on Jan 02, 2010

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Xl15 wiring schematics


Request a wiring diagram directly from Alpine Air.

May 12, 2017 | Air Air Purifiers

1 Answer

Got no power on my alpine xl15, someone told me the rectifier seems to fried and to change it, does anyone know where I might order this part? Thank You, Nemo Kim


Please check the fuse first. Unscrew or unlatch the small knob at the back of the machine and inspect the fuse. Even if it looks OK, you probably should replace it. Be sure to get one that is the EXACT same size, available at an auto parts store. If the fuse was the problem, the new fuse should allow your machine to power up and work well.

Make sure the plates are inserted firmly and correctly into the grooves at the top and bottom, so the fingers press firmly on the screen portion.

If the fan now works, but you aren't detecting any purifier (or hearing the buzz caused by the electricity cycling through the plates) you'll need a new transformer. This sends the power through the contact fingers to the plates. Vollara (formerly Alpine/EcoQuest) no longer makes the XL15. The newer machine is called the Classic. Call customer service and they'll tell you what your options are. 800-989-2299. Use #16618 if you need a referral number.

Jan 11, 2011 | Alpine Air XL-15 Air Purifier

1 Answer

I bought my Living Air XL15 in Ebay. It was


The ozone plate may need to be replaced.

Mar 01, 2010 | Alpine Air XL-15 Air Purifier

2 Answers

I have an Alpine Living Air XL15 which doesn't produce ozone . It has new plates but I,m told the plates should glow or sizzle. Can you tell me what the voltage should be at the grid plates. I had the...


The plates should not glow, but on High, you should hear a buzzing sound. But, you should also smell the ozone. I've only worked on two, but the reason they both didn't work was that the connectors on the wires leading to the plates were corroded beyond use. The top connector was the worst. Cutting them off and installing new ones solved the problem. Also, when you clean it, always clean the contacts where they touch the plates with alcohol. Look at the plates to see if they have more than one spot of glue around the center of the plate. (both sides) If so, they will be less noisy than older ones. Hint - Replace the plates when the glue on them turns dark brown.

Apr 01, 2009 | Alpine Air XL-15 Air Purifier

1 Answer

New noise


Hi wendie286,

An electrical hum (for the plasma discharge plates) is normal. If you wind-up the "Purifier" control knob to "max", it will increase, and you'll probably be able to see a faint purple glow coming from th plates. This is normal, and is how the O3/activated oxygen is being produced.

A mechanical hum sounds more like the fan motor. These are the only moving parts and do eventually wear-out. If it's still turning, it shouldn't be a problem - - if it starts turning slower and slower, it's time to plan a replacement motor. I have a couple, but I think FixYa's terms forbid me selling it to you directly. Recommended solutions in this case:
1) If you still know an active dealer, you might see if they have any
2) You could probably find them on the web, though the last time I did this (in December), I couldn't seem to find them; I didn't have a lot of time to spend then.
3) Find another XL15 (maybe on eBay) and cannibalize a fan from the older machine (note: different versions of the XL15 had different motor mounting configurations, so me sure you know what you're getting - maybe ask for a digital picture of the prospective purchase showing how it's mounted).

If you write back with more details, I may be able to offer more precise guidance.

If I can be of further assistance, or if you have questions, let me know before rating me.

If this solves the issue, please rate it accordingly. My goal is to earn a "FixYa" rating from everyone I help.

Thanks for using Fixya.com,

Jon

Jan 18, 2009 | Alpine Air XL-15 Air Purifier

2 Answers

ALPINE XL15


Hi jackkikay,

A faint buzzing sound is normal - - that's the high-voltage plasma discharge simulating lightning in a thunderstorm. If the room is dark you should be able to see a faint bluish-purple glow of the metal grid on the plate(s) inside. This should somewhat louder as you increase the setting.

It should not really be so loud that is stands out in the background of normal noises (refrigerator running for example). If the buzz is loud - - like something is shorting-out internally (loud crackling sound), that would signal a different problem - - I'd need more details about what you're observing. Approximate purchase day, specific model, number of plates, general condition of the interior would all be helpful if you deem the buzz to be too loud for normal operation.

If I can be of further assistance, let me know. If this helps or solves the issue, please rate it accordingly.

Thanks in-advance for using Fixya.com,

Jon

Oct 29, 2008 | Air Purifiers

3 Answers

ALPINE AIR XL15


If that's one of those fanless air purifiers with parallel plates, it is not all right. The plates need to come up to charge and not discharge much at all unless there is a big contaminant particle (e.g. flying insects.) You may or may not be able to make the plates parallel again; there should be no sharp bits. If it's an ionizer, even then the flashing should be rare; otherwise you will get more ozone than you need. That can be fun, but it is not making plain old clean air....

Jun 23, 2008 | Alpine Air XL-15 Air Purifier

1 Answer

Xl15 sparking


Clean the contacts that touch the plates with Qtips and 70% or higher isopropyl alcohol and replace the plates. Sparking on the plates usually is a sign of a crack in the plate. The electricity is passing through the plate, creating an arc. The crack may be invisible to the naked eye.

Apr 09, 2008 | Ecoquest Living Air Classic Air Purifier

1 Answer

Alpine Air Living Air XL15 not producing Ozone or Deodorizing. New plates


Confirm that the appropriate sections of the circuitry are powered up and drawing power; check the interlock switch action; toss it back to the maker because the Hi-V transformer or ladder circuit or sense or hold caps were (if testing proves) never quite functional.

Dec 03, 2007 | Alpine Air XL-15 Air Purifier

Not finding what you are looking for?
Ecoquest Living Air Classic Air Purifier Logo

Related Topics:

205 people viewed this question

Ask a Question

Usually answered in minutes!

Top Ecoquest Air Purifiers Experts

fordexpert

Level 3 Expert

5474 Answers

Michael Youngman
Michael Youngman

Level 2 Expert

156 Answers

The Knight
The Knight

Level 3 Expert

73691 Answers

Are you an Ecoquest Air Purifier Expert? Answer questions, earn points and help others