Hello, I have a error code H16 in a Panasonic air conditioner CS-E12EKK / CU-E12EKK end i want check and I would like tested with a tester the part corresponding to this code Thank You By Advance Ben

Hello, I have a error code H16 end i want check and I would like tested with a tester the part corresponding to this code Thank You By Advance Ben

Posted by on

  • MYMechanical May 11, 2010

    what does the code mean and what part needs testing

×

2 Answers

  • Level 1:

    An expert who has achieved level 1.

    MVP:

    An expert that got 5 achievements.

    Governor:

    An expert whose answer got voted for 20 times.

    Hot-Shot:

    An expert who has answered 20 questions.

  • Contributor
  • 21 Answers

H16 Outdoor Current Transformer open circuit
• Outdoor PCB
• IPM (Power transistor) module
or try this manual page 21

http://www.hetluften.se/contents/sv/Servicemanual_TE9_TE12_DKE.pdf

Posted on Jun 17, 2009

  • Level 1:

    An expert who has achieved level 1.

    Corporal:

    An expert that has over 10 points.

    Mayor:

    An expert whose answer got voted for 2 times.

    Problem Solver:

    An expert who has answered 5 questions.

  • Contributor
  • 4 Answers

Compressor

Posted on Dec 31, 2009

×

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Power indicator just keeps blinking


H16 on this model means that either the power supply transformer has failed, The outdoor PCB has failed or the machine is low on gas.

This info is from the Panasonic service guide. The outdoor unit LED 1 is on, LED 2 is on, LED 3 is off, LED 4 is off.
H16 On On Off Off Current Transformer Problem Power Transistor Module or Outdoor PCB Faulty. Very Low Gas

Mar 28, 2014 | Panasonic Heating & Cooling

1 Answer

Blue star split 1.5 tr ac eror code e5


The H16 code came on, still does not work machine how to solved H16 error. ???

Jul 02, 2012 | Heating & Cooling

1 Answer

I have a Panasonic air conditioner model CU-E12EKU (inverter). The unit stop working and the timer indicator is blinking. I checked for this error and followed the instructions in the Operating Manual,...


Not sure if yours has a letter 'H' before the 16 but if it does, it's the:
- Outdoor Current Transformer open circuit.
which means that your outdoor controller board is faulty.

Sep 08, 2011 | Panasonic Heating & Cooling

1 Answer

Panasonic air conditioner cs e28gkr, has error code f97.


f-97 out door compressor over heating due to in sufficient refrigerant. Check leak and arres ***. do gas charging.

Jan 01, 2011 | Panasonic Heating & Cooling

1 Answer

FAULT CODE H19? WHST IS IT? panasonic air conditioner cs/cu-e18jkr.


H-19 Error code means indoor fan mechanism locked. replace fan.

Dec 12, 2010 | Heating & Cooling

1 Answer

I have a problem with my panasonic cs-e12ekk H16 ???


Normal 0 MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman";}
Hi,

Here is a tip about troubleshooting your air conditioner...
There are many things that can cause your air conditioner not to cool…

Air Conditioner Trouble - Review the Possibilities

heatman101

Sep 02, 2010 | Panasonic Room Air Conditioner CWXC104HU

1 Answer

Panasonic air conditioner CS-E24GKR...The unit stops and the timer indicator blinks. Also displays error code H 11...Help...Please...its hot in here


H-11Indoor / outdoor abnormal communication. Check • Internal / external cable connections
• Indoor / Outdoor PCB

Jan 04, 2010 | Panasonic CS-A12C Air Conditioner

1 Answer

WHAT IS ERROR CODE F96 ON A PANASONIC INVERTER AIR CONDITIONER - MODEL CS-E28HKR ?


F-96. Over heating protection. to solve it-------Check for • Excess refrigerant
• Improper heat radiation
• IPM (Power transistor)

Nov 21, 2009 | Toyotomi TID-1800HP Air Conditioner

1 Answer

Panasonic split system air con cs/cu-e24gkr


check the indoor unit sirkit board,there is problem.

Feb 14, 2008 | Heating & Cooling

Not finding what you are looking for?
Panasonic Room Air Conditioner CWXC104HU Logo

Related Topics:

3,267 people viewed this question

Ask a Question

Usually answered in minutes!

Top Panasonic Heating & Cooling Experts

Bill Long

Level 3 Expert

587 Answers

Fotis Papastamatiou

Level 2 Expert

96 Answers

Dennis Boxerman

Level 3 Expert

1033 Answers

Are you a Panasonic Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...