Question about Computers & Internet

3 Answers

Time/date never stay set.f1 f2 f3 always there on start up

My laptop always needs F1 F2 or F3 pressed before loading why is this AND also the time/date never stay set im running on windows 2000 service pack 4. i have back up disks from my hp laptop for windows xp so am i able to up from windows 2000 to xp onto my compaq or is there alot more to it tanx for any help

Posted by on

  • steve May 29, 2009

    a big tanx for the help on my compaq laptop you r ALL so helpfull this site is great il probably never be off it hahha .



    all the best steve

    ssideburns@hotmail.com

×

3 Answers

  • Level 1:

    An expert who has achieved level 1.

    Hot-Shot:

    An expert who has answered 20 questions.

    Corporal:

    An expert that has over 10 points.

    Mayor:

    An expert whose answer got voted for 2 times.

  • Contributor
  • 31 Answers

This sounds like the cmos battery is low.
This battery sits on your motherboard and provides the ROM with energy. Replace this small battery, set date and time a final time and then it won´t happen again.

Posted on May 28, 2009

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 3,600 Answers

Your bios battery is bad take it to a shop have it fixed, laptops are hard to work on if you don't know where things are and it won't cost that much a cmos battery is about 5 bucks and then the charge for labor to replace it.

Posted on May 28, 2009

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 4,806 Answers

Hi there.
In response to you being able to upgrade from Win2000 to WinXP yes you can with no problems, just set the CD as the first boot device in the bios and pop the XP disk in the drive.
Now the reason it won't keep date and time is because the CMOS battery is dead and needs to be replaced, this is why you have to keep hitting the F keys to get it to boot into Windows, to get to the CMOS battery i am in no doubt that the laptop has to be disassembled to get to it, the only other way around is it to keep on setting the date and time in the BIOS every time you turn on the computer.
Please post back if you need any additional advice.

Good luck and thanks for choosing FixYa!!

Posted on May 28, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

How do I get it to go into bios when pressing f2 doesn't work?


Per the internet site, it depends upon the model of laptop. Here are some examples:

Laptops - Access Bios Settings Key

Issue


The most common Access Bios key is the "DEL" button or "F2". This depends on the laptop model, however, and can be confusing if you do not know which key to press.


Solution


Here is a list of laptop models and brands with the keyboard commands / key for accessing the BIOS Setup:



Acer: F1, F2, CTRL+ALT+ESC

ARI: CTRL+ALT+ESC, CTRL+ALT+DEL

AST: CTRL+ALT+ESC, CTRL+ALT+DEL

Compaq 8700: F10

CompUSA: DEL

Cybermax: ESC



Dell Laptops:

Dell 400: F3, F1

Dell 4400: F12

Dell Dimension: F2 or DEL

Dell Inspiron: F2

Dell Latitude: Fn+F1 (while booted)

Dell Latitude: F2 (on boot)

Dell Optiplex: DEL

Dell Optiplex: F2

Dell Precision: F2



eMachine: F2

Gateway 2000 1440: F1

Gateway 2000 Solo: F2

HP (Hewlett-Packard): F1, F2 (Laptop, ESC)

IBM: F1

E-pro Laptop: F2

IBM PS/2: CTRL+ALT+INS after CTRL+ALT+DEL

IBM Thinkpad (newer) Windows: Programs-Thinkpad CFG.



Micron: F1, F2, or DEL

Packard Bell: F1, F2, Del

Seanix: DEL

Sony VAIO: F2

Sony VAIO: F3

Tiger: DEL



Toshiba 335 CDS: ESC

Toshiba Protege: ESC

Toshiba Satellite 205 CDS: F1

Toshiba Tecra: ESC then F1 or F2



Toshiba Notebook [Newer models]:


  • Turn on the computer by holding down the power button while pressing the ESC key



    • The machine will beep, then display:




    • Check System, then press [F1] key.





  • Release the ESC key


  • Press the F1 key


Laptops Access Bios Settings Key

Apr 03, 2015 | Computers & Internet

Tip

Troubleshooting KitchenAid oven, range and microwave error codes


Here list of Kitchen Aid range and oven codes.
4 Digit Failure Codes
F1 - E0 EEPROM communication error
F1 - E1 EEPROM checksum error
F1 - E2 UL A/D error
F1 - E4 Model ID error
F1 - E5 Calibration shifted
F1 - E6 Latch signal mismatch error
F1 - E9 Stack overflow
F1 - E3 Wiring harness cavity size does not match stored value
F2 - E0 Shorted touch pad
F2 - E1 Keypad cable connection error
F2 - E5 Cancel key drive line open
F2 - E6 Cancel key drive line open
F3 - E0 Oven temperature sensor (RTD) opened (upper oven on double oven models)
F3 - E1 Oven temperature sensor (RTD) shorted (upper oven on double oven models)
F3 - E2 Oven temperature is too high (Cook mode)
F3 - E3 Oven temperature is too high (Clean mode)
F3 - E4 Oven temperature sensor (RTD) opened (lower oven on double oven models)
F3 - E5 Oven temperature sensor (RTD) shorted (lower oven on double oven models)
F3 - E6 Drawer sensor open
F3 - E7 Warming drawer sensor shorted
F4 - E1 Meat probe malfunction - shorted
F5 - E0 Door Switch
F5 - E1 Self clean latch will not lock
F5 - E2 Latch during CLEAN error
F5 - E5 Self clean temperature not reached within 45 minutes.
F5 - E6 Door is open, but latch is locked
F5 - E7 Self clean latch will not unlock
F6 - E0 Return line not connected
F7 - E1 Common switch wire defective
Two digit codes:
F0 ERC Board failure
F1 ERC Board failure
F2 Oven temperature is too high
F3 Oven temperature sensor open
F4 Oven temperature sensor shorted
F5 ERC Board failure
F7 Function key stuck on ERC
F8 ERC Board failure
F9 Oven door lock failure
Microwave and Microwave combo error codes:
F1 - E3 or F1 - E4 Electronic control malfunction
F2 - E0 or F2 - E1 Keypad connection error
F2 - E3 Keypad held down too long, or keypad is shorted.
If you get an error code, try first resetting the code:
1. Disconnect power for about two minutes.
2. Connect back power.
3. If code re-appears, test and eventually replace faulty part.

on Apr 24, 2015 | Kitchen Ranges

Tip

Troubleshooting KitchenAid oven, range and microwave error codes


Here list of Kitchen Aid range and oven codes.


4 Digit Failure Codes

F1 - E0 EEPROM communication error
F1 - E1 EEPROM checksum error
F1 - E2 UL A/D error
F1 - E4 Model ID error
F1 - E5 Calibration shifted
F1 - E6 Latch signal mismatch error
F1 - E9 Stack overflow
F1 - E3 Wiring harness cavity size does not match stored value
F2 - E0 Shorted touch pad
F2 - E1 Keypad cable connection error
F2 - E5 Cancel key drive line open
F2 - E6 Cancel key drive line open
F3 - E0 Oven temperature sensor (RTD) opened (upper oven on double oven models)
F3 - E1 Oven temperature sensor (RTD) shorted (upper oven on double oven models)
F3 - E2 Oven temperature is too high (Cook mode)
F3 - E3 Oven temperature is too high (Clean mode)
F3 - E4 Oven temperature sensor (RTD) opened (lower oven on double oven models)
F3 - E5 Oven temperature sensor (RTD) shorted (lower oven on double oven models)
F3 - E6 Drawer sensor open
F3 - E7 Warming drawer sensor shorted
F4 - E1 Meat probe malfunction - shorted
F5 - E0 Door Switch
F5 - E1 Self clean latch will not lock
F5 - E2 Latch during CLEAN error
F5 - E5 Self clean temperature not reached within 45 minutes.
F5 - E6 Door is open, but latch is locked
F5 - E7 Self clean latch will not unlock
F6 - E0 Return line not connected
F7 - E1 Common switch wire defective

Two digit codes:

F0 ERC Board failure
F1 ERC Board failure
F2 Oven temperature is too high
F3 Oven temperature sensor open
F4 Oven temperature sensor shorted
F5 ERC Board failure
F7 Function key stuck on ERC
F8 ERC Board failure
F9 Oven door lock failure

Microwave and Microwave combo error codes:

F1 - E3 or F1 - E4 Electronic control malfunction

F2 - E0 or F2 - E1 Keypad connection error

F2 - E3 Keypad held down too long, or keypad is shorted.

If you get an error code, try first resetting the code:
1. Disconnect power for about two minutes.
2. Connect back power.
3. If code re-appears, test and eventually replace faulty part.

Regards.

on Mar 27, 2010 | KitchenAid KHMS155LSS 1000 Watts Microwave...

1 Answer

HOW DO I BATCH OUT


GETI CHECK SALE [F2]
PAYROLL/BUSINESS [F3]
MORE VERIFY ONLY [F4] Press the Purple key below the More option. GETI CHECK SCANNER MENU [F1]
BATCH MENU [F2]
REPRINT [F3]
MORE VOID [F4] Select Batch Menu [F2]. ERASE BATCH [F1]
CLOSE BATCH [F2]
HISTORY REPORT [F3]
BATCH REPORT [F4] Select Close Batch [F2]. KEY IN MANAGER PASSWORD
AND PRESS ENTER Press [1] and [Enter]. ARE YOU SURE? CLOSE BATCH [F3]
CANCEL [F4] Select Close Batch [F3]. DIALING . . . The terminal will dial in to close the batch. Once closed, the terminal will print the batch report indicating Batch Accepted.
See example below. BATCH ACCEPTED
EXIT [F4] Select Exit [F4] to return to the menu.

Oct 19, 2011 | VeriFone VX510

Tip

Whirlpool oven, stove and range fault codes (ERC and EOC display errors).


Here a list of Whirpool oven fault codes. The codes had been collected from different service manuals. This was a memo that I wrote for my own use. I think this can be useful to owners and technicians.

WHIRLPOOL - most models
Range/Stove and Oven Fault Codes, Common error codes.

F1 - Analog control board Failure
Disconnect for one minute - if error comes back, replace control board
F1 - Shorted control keypad
Replace keypad
F3 - Oven temperature sensor open
Replace oven temperature probe
F2 - Oven temperature sensor shorted
Replace oven temperature probe
F3 - Oven too hot
Replace oven temperature probe
F3 - Clean temperature too hot
Replace oven probe
F5 - Door latch switch fault
Test and replace the door switch.


Whirlpool with 4 Digit Failure Code:

F1 - E1 - Electronic control (flip flop)
Replace control board
F2 - E0 - Shorted control keypad
Replace keypad
F3 - E0 - Oven temperature probe open
Replace temperature probe
F3 - E1 - Oven temperature probe shorted
Replace temperature probe
F3 - E2 - Oven temp too high
Replace temperature probe
F3 - E3 - Clean temp too hot
Replace temp. probe
F5 - E0 - Check door latch
F5 - E1 - Check door latch
Replace switch if defective

WHIRLPOOL Polara models 5 digit codes:

F1 F0 - EEPROM communication error
Replace ERC
F1 E1 - EEPROM checksum error
Replace ERC
F1 E2:7 - UL A/D errors
Replace ERC
F1 E4:2 - Model ID error
Reinsert keytail.
F1 E6:0 - Latch signal mismatch error
Replace ERC
F2 E0:4 - Shorted key error
Replace keypad assembly
F2 E1:3 Keytail unplugged
reinsert the keytail
F3 E0:5 Top oven sensor open
Test and replace top probe.
F3 E1:6 Top oven shorted
Test and replace temp probe
F3 E2:9 Bake range over temperature
Test and replace temp probe
F3 E3:8 Clean range over temperature
Test and replace temp probe.
F3 E4:10 Bottom oven sensor open
Test and replace temp probe
F3 E:15 Bottom oven sensor shorted
Test and replace temp probe
F5 E0:14 Door switch errot
Test and eventually replace door lock switch
F5 E1:16 Door latch not operating
Test and eventually replace door latch
F8 E0:17 Refrigeration error
Test the cooling module.
PF Power failure - Does not indicate a fault.
PF occurs when power is disconnected.

WHIRLPOOL
Models SF3, 30'' and 24"

F2 - Oven temperature above specifications
Check 8-pin connector from temp. probe to Electronic Oven Control
F3 - Open oven temperature probe failure
Check wiring, replace oven probe if necessary
F4 - Shorted oven temperature sensor failure
Check wiring harness, replace oven temperature probe if necessary
F5 - Push button stuck or faulty
Check for binding of pushbuttons and control panel glass. If OK, replace touch panel
F6 - Electronic control logic error (timing)
Replace Electronic Range Control (ERC)
F7 - Electronic control logic error (lock motor)
Replace ERC.
F8 - Electronic control logic error
Replace ERC.

on Jan 31, 2010 | Whirlpool RBS305PDS Electric Single Oven

1 Answer

I dont know what some of the buttons are on my keyboard. like therre is a circle with a check mark in it(F3) and another circle that has a 1/4 colored in (F2) and (F1) is just a ?


ok friend. press those botton with FN.
Exam: FN+F2 SHOW YOU COMPUTER CONTROL PANEL.
FN+F3 SHOW YOU POWER OPTION.
FN+F1 SHOW YOU HOTKEYS HELP.

Jan 30, 2010 | Acer Aspire 5315 Notebook

1 Answer

I need to know how to get to reduced row echelon form


Hello,
The matrix cell operations (row calculations, column operation) are accessed as follows:

Press [Menu] button. Highlight [MATRIX] icon and press [EXE]. The list of matrices is diplayed. If you already created the matrix, it will be listed and you can select it (using the arrows) and press [EXE].
Three menu items are displayed:
F1:R.OP (Swap, XRw,XRw->,Rw->
F2:ROW (Del, Ins, Add)
F3: COL (Del, Ins, ADD)

Matrix Operations are accessed in RUN screen by pressing [OPTN] and selecting [F2:MAT] . Availabble options ( they are commands) are
F1: Mat displays identifier Mat on screen
F2: M->L converts a matrix to a list
F3: Det Calclates the determinant
F4: Trn Calculates the transpose of a matrix
F5: Aug Augments a matrix
F6 -> accesses additional operations
F1:Iden Create an identity matrix with specified dimensions
F2:Dim
F3: Fill

In addition to the foregoing you have the matrix operations (+, -, x, square, inverse).
However there is an additional piece of software that performs the row echelon reduction on the CFX9850GBPlus. The information is available here (page 13: program ROWREDA)

The program can be downloaded from this site.

Hope it helps.


Aug 15, 2009 | Casio FX-9750GPlus Calculator

1 Answer

Toshiba Satellite 1400


To Access the Bios Setup Utility Here Is A List Of Key Commands And The Make/Model They Are For..

Acer - Aspire, Power, Veriton, Extensa, Ferrari, TravelMate, Altos
  • Press Del or F2 immediately after powering on.
  • The BIOS on the Acer Altos 600 server uses the Ctrl+Alt+Esc key and the F1 key for advanced options.
  • Older Acer computers may use also use the F1 or Ctrl+Alt+Esc keys to access BIOS.
Compaq - Presario, Prolinea, Deskpro, Systempro, Portable
  • Press F10 while the cursor in the top right corner of the screen is blinking.
  • Older Compaq computers may use the F1, F2, F10, or Del key to give access to BIOS.
Dell - XPS, Dimension, Inspiron, Latitude. OptiPlex, Precision, Vostro
  • Press F2 when the Dell logo appears. Press every few seconds until the message Entering Setup appears.
  • Older Dell desktops and laptops may instead use Ctrl+Alt+Enter or Del to enter BIOS.
  • Older Dell laptops may use Fn+Esc or Fn+F1.
eMachines - eMonster, eTower, eOne, S-Series, T-Series
  • Press Tab or Del while the eMachine logo displays on screen.
  • Other eMachine computers may use F2 to enter BIOS.
Fujitsu - LifeBook, Esprimo, Amilo, Tablet, DeskPower
  • Press F2 once the Fujitsu logo appears.
Gateway - DX, FX, One, GM, GT, GX, Profile, Astro
  • Press the F1 key repeatedly after restarting the computer.
  • Some older Gateway computers use F2 to access the BIOS Setup utility.
Hewlett-Packard (HP) - Pavilion, TouchSmart, Vectra, OmniBook, Tablet
  • Press the F1 key after restarting the computer.
  • HP Tablet PCs may use F10 or F12.
  • Other HP computers may allow access to BIOS using the F2 or Esc keys.
IBM - PC, XT, AT
  • Press F1 immediately after powering on the computer.
  • Older IBM computers (including some laptops) may utilize the F2 key for BIOS entry.
Lenovo (formerly IBM) - ThinkPad, IdeaPad, 3000 Series, ThinkCentre, ThinkStation
  • Press F1 or F2 after powering on the computer.
  • Older Lenovo products allow access to BIOS using Ctrl+Alt+F3, Ctrl+Alt+Ins, or Fn+F1.
Micron (MPC Computers) - ClientPro, TransPort
  • Press F1, F2 or Del immediately after powering on the PC.
NEC - PowerMate, Versa, W-Series
  • Press F2 to enter the BIOS Setup.
Packard Bell - 8900 Series, 9000 Series, Pulsar, Platinum, EasyNote, imedia, iextreme
  • Press F1, F2, or Del to enter BIOS.
Sharp - Notebook Laptops, Actius UltraLite
  • Press F2 after the computer starts.
  • Some very old Sharp PCs require a Setup Diagnostics Disk to access BIOS.
Shuttle - Glamor G-Series, D'vo, Prima P2-Series, Workstation, X Mini XPC, Surveillance
  • Press F2 or Del on startup.
Sony - VAIO, PCG-Series, VGN-Series
  • Press F1, F2 or F3 after turning on the computer.
Toshiba - Portégé, Satellite, Tecra
  • Press F1 or Esc after powering on to access BIOS.
The following companies are either closed for business or no longer manufacture or support mainstream computers systems so verifying the following BIOS access information is nearly impossible. I have included what I could dig up for anyone who might be interested:
ARI / ALR / AST (Advantage) - Press the Ctrl+Alt+Esc or Ctrl+Alt+Del keys.
Cybermax - Press the Esc key.
Tandon - Press the Ctrl+Shift+Esc keys.


Good Luck and Hope it helps...
http://www.wnycomputerpro.com

Jun 12, 2008 | Toshiba Satellite A35-S159 Notebook

2 Answers

Buttons


F1, F2, and F3 are the strength of the fan blowing the air conditioner. F1 circulates the least amount of air, F3 the most. I generally find that if the air conditioner isn't getting the job done on F1, F2 will do it. I typically only use F3 if I just want to circulate air fast in my place for awhile. As far as what is "better" with closed vent or open, that depends on what you want to do. If you are using air conditioning on a hot day, then vent closed is better because it will cool only air circulating in your place. Vent open will allow fresh air in from outside, and if it's a really hot day, the air conditioner might have a harder time cooling off the fresh air than the circulating air inside your place (as it's continually being cooled repeatedly by your air conditioner).

Jun 10, 2008 | Goldstar M1003R Air Conditioner

Not finding what you are looking for?
Computers & Internet Logo

Related Topics:

216 people viewed this question

Ask a Question

Usually answered in minutes!

Top Computers & Internet Experts

Doctor PC
Doctor PC

Level 3 Expert

7733 Answers

kakima

Level 3 Expert

102366 Answers

David Payne
David Payne

Level 3 Expert

14161 Answers

Are you a Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...