Question about Hayward 100,000 BTU Pool Heater H100ID1 - Above Ground

1 Answer

The pilot light won't come on

The pilot light on my heater won't come on

Posted by on

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Champion:

    An expert who has answered 200 questions.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

  • Expert
  • 246 Answers

Make sure the gas is open if is check the pilot must need to be clean or replace.replace the gas valve must be bad

Posted on Aug 19, 2009

  • Florinda Ramirez
    Florinda Ramirez Jan 06, 2014

    so if i changed out the thermocouple,and i get a strong spark from the igniter,but pilot wont light at all,could it be gas valve?and if so ,where is it located,?and is it hard to replace it?

×

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Pilot light wont light


Rita, Check the attached links,instruction and guides to trouble shoot pilot light, Good luck
"I hope this helped you out, if so let me know by pressing the helpful button. Check out some of my other posts if you need more tips and info."
Gas Heater Pilot Light Troubleshooting
What to Do if Gas Furnace Pilot Light Won Stay Lit DoItYourself com
Furnace Won Ignite Why and What to Do

Aug 03, 2016 | Heating & Cooling

1 Answer

Pilot light won't stay on


Dust gets inside the pilot safety during the months when it is not in use. Blow out the pilot safety without disturbing the flap. and retry.
ODS VENT FREE HEATER TUNEUP

Nov 12, 2012 | Empire ECS HearthRite HR18MN Heater

1 Answer

Delonghi Superser won't light there is gas getting


Clean pilot first see if it lights if not you could change thermocouple

Apr 03, 2012 | DeLonghi Heating & Cooling

2 Answers

My water heater won't light. The pilot light works. But, when I try to swtch the pilot to regualr, the flame goes out.


You probably have a defective thermocouple. The thermocouple sits in the flame of the pilot, and the heat generates a small electrical current conducted back to the gas valve, keeping the pilot gas line open after you switch it to the "on" position. That's why you have to manually hold the gas valve depressed (on) during lighting in the "pilot" position, allowing the thermocouple time to heat up enough to generate its current. A defective thermocouple will not generate the holding current.

Jan 06, 2012 | Heating & Cooling

1 Answer

Sterling RF-45 Pilot light comes on and the burner won't fire. The pilot goes out and fan keeps running.


clean pilot check flame sencor is clean , jump high leval limit first see if it lights , if not try low limit , check thermocouple is tight if fitted ,

Sep 24, 2011 | Sterling RF45 Propane Gas Heater (45,000...

1 Answer

I can light the pilot and the burner will come on, but it won't stay lit. I bought a new pilot assembly and installed it. the burner and the pilot light still won't stay lit. This is the unit that...


Most gas water heater problems can be solved by having service technician perform yearly maintenance. Or by doing maintenance yourself.
This maintenance includes cleaning burner parts and combustion chamber, checking gas pressure and supply, bleeding air out of gas line, checking vent draft, making sure air supply is adequate and not exposed to chemicals, cleaning air intake. Also adjusting flame sensor so it is positioned correctly. If water heater is connected to electric circuit, the outlet must have correct polarity.

You can get gas to appliance indicates the gas control valve and water heater are not locked out. But the gas control valve thermostat can still be bad.

Open following link for illustrations, typical service manuals, and maintenance information, and images of gas control valve thermostats.
http://waterheatertimer.org/How-to-install-gas-water-heater.html#troubleshoot

Jul 20, 2011 | Reliance & Pilot Assembly for Natural Gas...

1 Answer

Pilot will light after 30 seconds when you try to move knob to on position the pilot goes out and heater won't ignite.


You need to replace the thermocouple.
When you light the pilot it is supose to heat the thermocouple.
the thermocouple produces a small electric current which allows the gas valve to open and keep the pilot going. and allowing the main burner to come on.

Jun 21, 2011 | RTO Atwood Water Heater - 6 Gal LP

1 Answer

Williams debonair wall heater + pilot light problems


THE flame from the pilot should shoot past the thermo-couple and heat this up and make a small amount of mili- amps to prove the pilot light is lit. ..So if the flame doesn,t go past the thermo-couple it won, make mili-amps or its tme to change out the thermo-couple, They only cost lest than $8:00 and you can change it!

Dec 22, 2009 | Williams 3003622 Ceramic Wall Mounted...

Not finding what you are looking for?

Open Questions:

See all Hayward 100,000 BTU Pool Heater H100ID1 - Above Questions

Hayward 100,000 BTU Pool Heater H100ID1  - Above Ground Logo

Related Topics:

162 people viewed this question

Ask a Question

Usually answered in minutes!

Top Hayward Pool & Spa Experts

Jay Finke
Jay Finke

Level 3 Expert

1339 Answers

Bill Jordan

Level 2 Expert

372 Answers

john h

Level 3 Expert

12166 Answers

Are you a Hayward Pool and Spa Expert? Answer questions, earn points and help others