Generac 43903 standby Generator overspeed indicator on starting

Posted by Anonymous on

3 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

CarlGehrke
  • 169 Answers

SOURCE: 10kw Generac shut down overspeed

Make sure that the throttle linkage is all there and not damaged/misadjusted, then get a manometer and check your inlet gas pressure. Gas pressure should be 8 inches of water column and stay there running or not.

Carl

Posted on Apr 06, 2009

  • 14 Answers

SOURCE: Generac 43903 standby Generator overspeed indicator on starting

I have a generator that did the same thing. It would start and then stop within a few seconds. The more expensive generators have an oil level safety switch to prevent the engine from burning up. There is usually a wire connecting to the switch on the outside of the engine near the oil fill hole. Remove this wire and try to start the generator. If it runs without a problem then it is the switch. You need to remove the switch and take it apart carefully and clean it. There is a small float inside the assembly. When the oil runs low the float allows the switch to short to ground which kills the spark to the spark plug. Hope that helps.

Bob Janelli

Posted on Oct 01, 2009

Testimonial: "This is good information in the event that the low oil switch is part of the problem."

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Generator hard to start and sputters like its missing


About 15,000 results (0.73 seconds) Search Results

    2 - Generac : Questions, Answers, How To, FAQs, Tips ...

    answers.generac.com/answers/1506-en_us/searchquestions.htm?...
    Can I run an 8kw standby generator on a 100 lb propane tank? 2 answers ... What am I getting for the extra cost of the Guardian unit? ... The engine starts hard and runs rough. 1. Air ... On auto start, unit sputters and I smell gas. ... Does the gas and electrical feed into the unit from the back as previous air cooled units?

    2 - Generac Questions and Answers

    answers.generac.com/answers/1506.../generac.../questions.htm?...
    On auto start, unit sputters and I smell gas. .... The 20kW automatic standby generator has the option to delay start up during an ... This is for a guardian 20kw. ....has been designed to make the battery installation and removal so difficult? ... The air cooled generators are designed to allow for the smallest footprint while still ...

    3 - Generac Questions and Answers

    answers.generac.com/answers/1506.../generac.../questions.htm?...
    Generac's Guardian Series 17kw automatic standby generator does not come with a.... The automatic response features of our air-cooled units initiates the unit's startup,.... This week I tried the same and it tries to start but just sputters and fails until .... A C delayed start still chocks 17kw generator would a hard start kit help?

    On auto start, unit sputters and I smell gas. On manual start ...

Feb 08, 2016 | Generac Guardian Air-Cooled Standby...

1 Answer

Why does it crank and almost start on 1st try?


Generac Generator Troubleshooting - YouTube

? 1:39
https://www.youtube.com/watch?v=AKN2dc59cxY
Dec 20, 2013 - Uploaded by Appliance Princess
I want to learn about Generac generator troubleshooting. ... I have a 16 kW propane fueled standby air-cooled generator. ... I have a brand new generac 20K guardian Evolution and the first time my power went out my generac ...

Generac Power Systems - ConsumerAffairs.com

www.consumeraffairs.com > Homeowners > Utilities

Rating: 1.3 - ‎26 votes
Hey, Generac, make a change and start making generators that work, don't cost .....Standby generators are not supposed to be used as a primary power source ... and three months ago, I spent $4,000 to have a Guardian generator installed at ...

Generac standby generator - Propane - wont start?? - DoItYourself ...

www.doityourself.com/.../487838-generac-standby-generator-propane-w...
Feb 4, 2013 - I have a Generac 4LM41A standby generator that I need help introubleshooting and repairing. It is about 12 years old and hasn't been used ...

141 GENERAC complaints and reviews @ P'ed Consumer


Dec 12, 2015 | Generac GUARDIAN Standby Generator 10 kW/9...

1 Answer

Generac Guardian 12 KW Model 04456-2 shuts down on overspeed in cold weather


Leigh,
See my 5/22/12 comments on my "overspeed fault" problem resolution [Generac 43903 standby Generator overspeed indicator on starting] . If it only runs for a few seconds and then quits, you may have a similar condition to the one my unit had. A good technician should be able to diagnose the problem and determine if you have a similar failure to the one I had, or one of the other causes suggested by RSG000.

Jan 20, 2012 | Generac 13,000 Watt / 13,000 Watt Home...

6 Answers

Generac 43903 standby Generator overspeed indicator on starting


I have a generator that did the same thing. It would start and then stop within a few seconds. The more expensive generators have an oil level safety switch to prevent the engine from burning up. There is usually a wire connecting to the switch on the outside of the engine near the oil fill hole. Remove this wire and try to start the generator. If it runs without a problem then it is the switch. You need to remove the switch and take it apart carefully and clean it. There is a small float inside the assembly. When the oil runs low the float allows the switch to short to ground which kills the spark to the spark plug. Hope that helps.

Bob Janelli

Oct 01, 2009 | Generac 13,000 Watt / 13,000 Watt Home...

1 Answer

10kw Generac shut down overspeed


Make sure that the throttle linkage is all there and not damaged/misadjusted, then get a manometer and check your inlet gas pressure. Gas pressure should be 8 inches of water column and stay there running or not.

Carl

Apr 06, 2009 | Guardian Electrical Supplies

2 Answers

Generac Guardian 15 kw overspeed fault


Did you remember to set the overspeed shutdown threshold on the control board?

Apr 03, 2009 | Generac 13,000 Watt / 13,000 Watt Home...

1 Answer

Start runs shutsdown


Typically caused by the fuel line (LP or Natural Gas) having a lot of air in it. Was your generator just installed, or was there any work done to the gas line of the building / generator? Consult local gas contractor / propane dealer / gas company for assistance in purging the fuel line.

A low battery can also cause this as well as the generator is not able to come up to starting speed quick enough. Try placing a stand alone battery charger on the generator and charge the battery. Also check the air filter as well.

OverCrank condition occurs when generator tries to start itself, or be manually started, and the starter spends too much time turning.

This can also indicate failure of the control board. This will need the expertise of generac technician. Call 1-888-GENERAC (1-888-436-3722)
M-F 7am-6pm Central

Mar 29, 2009 | Generac 13,000 Watt / 13,000 Watt Home...

Not finding what you are looking for?
Electrical Supplies Logo

Related Topics:

196 people viewed this question

Ask a Question

Usually answered in minutes!

Top Generac Electrical Supplies Experts

 Kenneth
Kenneth

Level 2 Expert

50 Answers

Ottoniel

Level 2 Expert

202 Answers

JOHN LAPIER

Level 3 Expert

2422 Answers

Are you a Generac Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...