jtuminaro
  • 56 Answers

SOURCE: Brother 8460n Fuser Unit

Hit in sequence Menu,*,2,8,6,4
This will put it in maint. mode.
Press 88
That is parts counter reset, scroll down and hit ok on the part you want to reset the counter. :)

Posted on Jan 14, 2009

Ad
  • 5 Answers

SOURCE: RESETTING FUSER LIFE ON BROTHER HL5140 PRINTER

How to reset the pf-kit message on a brother hl-5140.

Posted on Aug 12, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Ho do I reset my MFC8480DN after replacing the fuser unit?


Hi,

This is the fuser reset procedure from page 563 of the service manual:

5.1 Resetting the Periodical Maintenance Parts Life
? Resetting the Life Counter of the Fuser Unit
<Function>
This function allows you to reset the page counter of the fuser unit and increase the number
of replacement times by one.
<Operating Procedure>
(1) Press the [3] and [9] keys at the same time in the ready state.
The "Reset Menu" will appear on the LCD.
(2) Press the [ ] button a few times to select "Fuser".
(3) Press the [OK] button.
The "1. Reset / 2. Exit" will appear on the LCD.
(4) Press the [1] key when resetting the life counter of the fuser unit. Press the [2] key if not
resetting.
(5) The "Accepted" will appear on the LCD if pressing the [1] key. The page counter of the
fuser unit is reset, and the number of replacement times is increased by one. Then, the
machine returns to the ready state. If pressing the [2] key, the machine do not reset the
page counter and the "Fuser" will appear on the LCD.

Feb 10, 2015 | Office Equipment & Supplies

1 Answer

Hello, I replaced the fuser on my 734de and I still get fuser life warning


Did you replace the fuser with a new Lexmark fuser or a refurbished unit? The original Lexmark units have a chip in them that resets the counter when installed. However this only works the first time the fuser is installed. If you install a used fuser in a different printer it will not reset the counter.

Sep 30, 2014 | Lexmark Office Equipment & Supplies

1 Answer

How do you reset maintenance count on a dell 3130?


You don't. You can't.

When you install a replacement Transfer belt (it has it's own counter chip) that resets the transfer belt pagecount, and as a result clears any transfer belt life related warnings/errors.

When you install a REPLACEMENT Fuser (that has it's own counter chip) that resets the fuser pagecount, and as a result clears any fuser life related warnings/errors.

PLEASE NOTE - The fuser supplied with the DELL 3130 when new DOES NOPT have a counter chip - the fuser life warnigs are triggered by the printer pagecount. Installing a fuser from another printer (even if it has a ZERO pagecount WILL NOT reset the fuser pagecount (because the 'ship with' fuser has no counter chip.

Aug 27, 2014 | Dell 3130cn Color Laser Printer

1 Answer

E studio 520 code c447


All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0." also 447

Jan 17, 2014 | Toshiba Office Equipment & Supplies

1 Answer

Error code c43


All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0."

Jan 14, 2014 | Toshiba Office Equipment & Supplies

1 Answer

Call for service C 430


All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0."

Dec 31, 2013 | Toshiba estudio 255 Copier

1 Answer

Hp cm4540 fuser kit counter reset


allot of the newer HP printers can not be reset they have a fuse in the new fuser when it is installed it blows the fuse in the new fuser & resets the count.

Aug 01, 2012 | HEWLETT-PACKARD CM4540 AllInOne Laser...

1 Answer

TOSHIBA E STUDIO 207 ERROR C 44


All error code soloution of fuser unit Fuser Unit Error Status Counter
Purpose
When a fuser unit related error (error code C41, C43, C44 or C45) occurs, the set value of the fuser status
counter varies, depending on type of error.
Displaying and checking the set value of the fuser status counter can analyze a cause for the error. If
any of "2 to 9" is set at the fuser status counter, the fuser unit will not be operated for safety reasons.
After the fuser unit related error is resolved, if "0" is set, the fuser unit will be operated as usual. If any of
"10 to 19" is set at the fuser status counter, the fuser unit will be operated as usual, even if "0" is not set
after the fuser unit related error is resolved.
C41: Thermistor or heater abnormality at power-ON
C43: Thermistor abnormality after abnormality judgment
C44: Heater abnormality after abnormality judgment
C45: Thermistor abnormality during printing
C46 to C49: Reserved
Description
When this code is used, the current set value of the fuser status counter is displayed. Only "0" can be
manually entered, in order to restore the fuser unit to its normal operation, after the fuser unit related
error is resolved.
For further reason why the counter value differs despite the same error code, refer to 5.1.7 or 5.1.8
[Fuser unit related service call] in the Service Handbook.
0: No error 10: C47 (Reserved)
1: C41 (Once) 11: C47 (Reserved)
2: C41 (Consecutively occurs) 12: C48 (Reserved)
3: C46 (Reserved) 13: C49 (Reserved)
4: C43 14: C47 (Reserved)
5: C44 15: C48 (Reserved)
6: C45 16: C49 (Reserved)
7: C44 17: C47 (Reserved)
8: C45 18: C48 (Reserved)
9: C44 19: C49 (Reserved)
* Default: 0
Setting Timing
Use this code to resolve the fuser unit related error (error code C41, C43, C44 or C45). Resolve the
error, and set "0" (or reset the counter), in order to restore the fuser unit to its normal operation.
Caution
Remember to resolve the fuser unit related error, and then reset to "0."

Jul 08, 2012 | Toshiba E Studio 207

2 Answers

How to resert the counter of the fuser of samsung clx 3185


Do it in Tech mode
Menu # 1 9 3 4 Menu
Navigate through the menus to find the Counters menu, fuser is in there from memory (I reset imaging unit only recently on CLX3185FN but saw fuser in the menu as another option)
Or you can wipe EVERYTHING with "clear all mem" option
Password 1934 worked fine for me

May 03, 2012 | Samsung CLX3185 Printer

3 Answers

Brother 8460n Fuser Unit


Hit in sequence Menu,*,2,8,6,4
This will put it in maint. mode.
Press 88
That is parts counter reset, scroll down and hit ok on the part you want to reset the counter. :)

Jan 05, 2009 | Brother MFC-8460N All-In-One Printer

Not finding what you are looking for?
Brother MFC-9840CDW Laser Printer Logo

Related Topics:

43 people viewed this question

Ask a Question

Usually answered in minutes!

Top Brother Office Equipment & Supplies Experts

CheckitRight
CheckitRight

Level 3 Expert

1362 Answers

James Cagle
James Cagle

Level 2 Expert

454 Answers

Samyfam
Samyfam

Level 3 Expert

379 Answers

Are you a Brother Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...