Question about Konica Minolta bizhub C450P Laser Printer

1 Answer

Bizhub C450: After replacing the image transfer roller & ozone

Filter, how do I reset the message to replace same?

Posted by on

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Vice President:

    An expert whose answer got voted for 100 times.

  • Expert
  • 210 Answers

In Service Mode -> Counter -> Life -> Select the one you want to reset and press 'C'

Posted on Aug 23, 2009

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Color printing is printed with a yellow background in bizhub c450


have you replace the Transfer belt.??? It also has a transfer roller for yellow. (Called First Transfer) since it is transferring yellow off the drum. You have replaced the yellow image unit???? 2nd transfer is to the paper!!!

May 18, 2016 | Konica Minolta bizhub C450P Laser Printer

1 Answer

Fuser unit


can you explain more the functions of each are as followed fuser melts the toner to the paper so it dosnt rub off ozone filter filters out the ozone so you don't get headaches and turn al the rollers to bubble gum transfer roller pushes the paper onto the transfer belt applying the image to the paper and imagine unit is where thetransfer belt gets the image from

Aug 16, 2014 | Konica Minolta bizhub Office Equipment &...

1 Answer

How I can reset counter imaging unit bizhub c450?


u cant reset those , u have to change the counter chips .These are available in market

Apr 19, 2012 | Konica Minolta Office Equipment & Supplies

1 Answer

The machine says "replace ozone filter" i did that but the message won't reset itself. is there something i can do to reset it?


On most models of Color Bizhub machines, to reset the ozone filter message you must go into service mode. Press the Utility/Counter button on your operation panel, select meter count, then detail, press stop,0,0,stop,0,1. This will put you in service mode. Find and press counter button, Locate life counters, and clear ozone filter. You will not be able to clear some of the counters in this menu. They are automatically cleared when the items are replaced.

Apr 23, 2010 | Konica Minolta bizhub C351 All-In-One...

1 Answer

I have a Konica Minolta Bizhub C350 which is now indicating that it needs to have the image transfer roller unite and paper dust/ozone filter replaced. Where are these located in the machine and is it...


I would advise having a copier technician replace those items it is not that hard to do but if you dont get the roller seated in the holder properly it can destroy the transfer belt and that could get expensive

Nov 29, 2009 | Konica Minolta bizhub 350 All-In-One Laser...

1 Answer

Reseting counter after installing new image transfer roller unit


You need to go into tech rep mode to reset.
press: stop 0 0 stop 0 1, then 0 0 0 0 0 0 0 0, press enter, then press counter on the left, select life, then highlight image trans roller and press the C button, repeat for paper dust remover and exit tech rep mode

Jan 17, 2009 | Konica Minolta bizhub 350 All-In-One Laser...

2 Answers

Konica Minolta Bizhub c351


you have to clear the counters in tech rep mode.
Utility - counter - details- then the following sequence....

stop-0-0-stop-0-1 then press counter - life - then highlight the parts you changed and press the C button, then exit .

Jul 23, 2008 | Konica Minolta bizhub C351 All-In-One...

1 Answer

Need a reset code


hey.
You have to go to service menu ---> stop -> 0 -> 0 -> stop -> 0 -> 1 ---- and choose counter -> maintance/parts counter find these parts on the list, make them blue/touch them and touch C.
then exit to normal mode

good luck

May 05, 2008 | Konica Minolta bizhub 350 All-In-One Laser...

2 Answers

Need to know how to reset codes


To reset the life counters for the transfer roller & ozone filter you will need to enter the service mode.

To do this press utilty, meter count,details(if available), then stop, 0, 0, stop , 0, 1.
You should now be in tech rep mode, select counters then life.
Select the transfer roller/ozone filter button and press the C key on the keypad.
It should zero the life count.
Now press end, exit etc until you back at the copy screen.

Warning: Please do not reset or clear any other data within tech rep mode or you may inadvertantly affect the performance of you machine.

Hope this Helps.

May 05, 2008 | Konica Minolta bizhub 350 All-In-One Laser...

Not finding what you are looking for?
Konica Minolta bizhub C450P Laser Printer Logo

1,574 people viewed this question

Ask a Question

Usually answered in minutes!

Top Konica Minolta Office Equipment & Supplies Experts

Norman  J Weimar Jr
Norman J Weimar Jr

Level 3 Expert

6161 Answers

Ben
Ben

Level 2 Expert

108 Answers

David Burkhart
David Burkhart

Level 2 Expert

210 Answers

Are you a Konica Minolta Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...