TV cant be switch on, RED LED diagnostic Blinks .. 3 times... then 4 times. Please advise probable cause and send sTV hcematic diagram.

When power is switch on, the two green LED lights up but the screen remain blank .. after a few seconds, two green LED switch off and the red LED diagnostic blinks 3 times... then 4 times ... then continue blinking 4 times.

Posted by on

  • 1 more comment 
  • prosant May 21, 2009

    Thanks Local wonder.. but I would like to correct ... model number is SONY KV29SF1. and this is the problem...." " " " " --> When power is switch on, the two green LED lights up but the screen remain blank .. after a few seconds, two green LED switch off and the red LED diagnostic lights up for 2 secs... then blinks 4 times .and continue blinking 4 times " . However, There are times that the TV will normally operate after switching on.. Suspect problem with Horizontal ckt - unable to generate horizontal sweep current to operate the CRT which is being sense by the microprocessor protective circuitry.? This is a guess... as I dont have ckt diagram .Please advise..

  • prosant May 21, 2009

    I studied Radio TV servicing but practice Control system engineering.. So I still understand quite well TV circuitry operation and can repair down to component leve -- given the correct information. l. I just need familiarity with the operation / function of the IC used in this KV29SF1 , service manual and ckt diagram will be very helpful. There is no Sony service center near our place so I have to fix the TV ..Will appreciate if anybody can e-mail me a copy of Schematic Diagram..

  • Anonymous Mar 17, 2014

    LED blink and no power and i need circuit diagram. my email address is stewardmoli@gmail.com

×

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    Superstar:

    An expert that got 20 achievements.

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

  • Master
  • 6,784 Answers

Hi, this is main board failure and you will need to replace this vital board. you power board is fine but, it is unable to send a proper current through the main mother board due to the damage at hand.

Posted on May 21, 2009

  • Michael Masters
    Michael Masters May 21, 2009

    Ckt is probable but, this component may be discontinued. i will do some further research on this a and return within the hour. this could be a faulty CRt tube as well. i will resarch this further...

×

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Sony TV set, KV20FS120 BA6 chassis: light blinks, set isn't coming on. Why?


Sony sets like this have a built-in self-diagnostic function.
The blinks of the Standby LED are the self-diagnostic codes.
There may be more than one error. The blinks indicate only the first error.

Unlug the set. Wait 30 seconds.
Prepare to count the number of times the Standby LED blinks.
Plug the set back in. Count the blinks.

2 blinks
  • Diagnostic Item Description: +B overcurrent (OCP)
  • Probable cause:
    • H.OUT (Q506) is shorted. (A Board) (20"/21" models only)
    • RGB Amp (IC1751) is shorted. (CV Board)
  • Detected Symptoms:
    • Power does not come on.
    • Load on power line is shorted.
4 blinks
  • Diagnostic Item Description: I-Prot
  • Probable cause:
    • +13V is not supplied. (A Board)
    • IC545 is faulty. (A Board)
  • Detected Symptoms:
    • Has entered standby state after horizontal raster.
    • Vertical deflection pulse is stopped.
    • Power line is shorted or power supply is stopped
5 Blinks
  • Diagnostic Item Description: IK (AKB)
  • Probable cause:
    • Video OUT (IC545) is faulty. (A Board)
    • IC001 is faulty. (A Board)
    • Screen (G2) is improperly adjusted.
  • Detected Symptoms:
    • No raster is generated.
    • CRT Cathode current detection reference pulse output is small.

The above may be of little help. Your best bet is to download the service manual for the KV20FS120.

...Google search: Sony KV20FS120 service manual

Apr 26, 2016 | Sony Televison & Video

1 Answer

I have 3 flashing red lights when I try to power up my TV.


Over Voltage Protection . this is the cause for 3 blinks you see by its stanby/power LED.


Visit the site named 'Electro-help' for more details. Click this link. View it in "Timeslide" option, which can be selected from the drop down box menu by the [Sidebar] tag, at the top left corner of the display window. It will make search easy. There are more than 1000 posts to different brand TVs now. Pull up older posts there.

Oct 12, 2012 | Sony BRAVIA KDL-40W3000 40 in. LCD HDTV

2 Answers

Sony Triniton TV KV 32FS120 will not turn on


In standby mode (red led on/after the led stops from blinking), press "Display", "5", Volume (-)", "Power on" on the remote control in sequence, self diagnostic screen will be display, let me know the what is on the screen to diagnose where the fault came from.

Nov 25, 2011 | Sony FD Trinitron WEGA KV-32FS120 32" TV

1 Answer

Bought in Dubai 3 years ago Pan.Viera LCD 32"\r\nStandby light flashing red/green. Have to switch on with on/off button after a few minutes switches off itself..........then back on itself


Power LED Blinking timing chart
When an abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, the defective block can be identified by the number of blinks of the Power LED on the front panel of the unit.
blinking

1 dg board, (stv 5v sense time out)
2 d board
3 d board
4 p board
5 d board
6 su sd sc boards
7 su sd sc boards
8 ss board
9 panel config
10 digi board-
11 pb board
12 h board
13 dg board

Tom Miller
Broadcast Eng

Mar 04, 2011 | Panasonic VIERA TX-32LXD80 32 in. HD-Ready...

1 Answer

I have 2 of these monitors with the same problem. On power up the green led will light & remain on but the screen remains black. On one of the monitors the screen will light up for a few seconds then...


The inverter that turns on the back light may be bad - it's suppose to create the high voltage pulses to fire the CCFL back light lamps. Apparently the back light turns on after a few seconds however, it cannot stay on because the inverter might be bad. If you connect a known external CCFL lamp to the to the inverter output you can isolate the inverter.

Dec 26, 2010 | NEC MultiSync LCD2010 20.1" LCD Monitor

2 Answers

I have a Graco baby monitor, it started making a noise for the last 2 days, could it be a battery problem (even with power connected)? The monitor is about 1.5 years old.


Annoying! happens to us too frequently, but this works. We ended up buying a new one and returning our broken one after owning for three months From Manual:) 5. Turn on the Nursery Unit using the On/Off switch on the side. The green power light should come on. 6. Within a few seconds, the Parent Unit will lock on to the Nursery Unit and the top four (4) green LEDs will shut off. A second later, you will hear a series of beeps and the connection LED should change from red to green. Your monitor is now ready for use. 7. If the top four (4) LEDs do not shut off, power off the Parent Unit and the Nursery Unit and repeat steps 4 and 5 above. 8. If the connection LED on the Parent Unit does not change from red to green and the unit begins to beep, press the channel "ch" button on the Nursery Unit. Within a few seconds, the Parent Unit should lock in on the Nursery Unit and the connection LED should change from red to green. You may hear an audible beep during this process. 9. If the Parent Unit is still unable to lock in on the Nursery Unit (connection LED will be red and the unit will beep), power down both the Parent Unit and the Nursery Unit. Wait for 10 seconds then hold the volume down button on the Parent Unit while pressing the On/Off switch. When the unit powers up, you will hear a single beep and all of the soundlights will illuminate. Release the volume down switch and within 2 seconds you will hear two beeps and all of the Sound Light LEDs will stay lit and the bottom LED will be red. 10. Repeat steps 5

Oct 12, 2010 | Graco Baby Care

1 Answer

When turned on green light flashes and no picture


Check the Lamp if no picture, audio may be present. Screen is completely dark. Lamp LED flashes 2X every 5 seconds, Power LED flashes GREEN for 140 seconds then flashes RED.
Check the ballast if no picture, audio may be present. Screen is completely dark. Lamp LED flashes 3X every 5 seconds, Power LED flashes GREEN for 140 seconds then flashes RED.

Dec 24, 2009 | Panasonic PT-50LC13 50" Rear Projection...

Not finding what you are looking for?
Sony KV-29FX30 29" TV Logo

Related Topics:

740 people viewed this question

Ask a Question

Usually answered in minutes!

Top Sony Televison & Video Experts

kakima

Level 3 Expert

102366 Answers

The Knight
The Knight

Level 3 Expert

73647 Answers

Jerry Greenberg
Jerry Greenberg

Level 3 Expert

1667 Answers

Are you a Sony Televison and Video Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...