Question about Kipor Parallel Wiring Kit, 30 amp Receptacle for IG2000P #66631

1 Answer

Engine cant run with air filter fitted, I have cleaned it .but the problem remains the same

I HAVE A KDE6500X/E/T KIPOR POWER GENERATOR. THE PROBLEM IS WHEN I TRY TO RUN THE ENGINE WITH AIR CLEANER ON THE ENGINE STALLS. BUT ENGINE RUNS WELL WITHOUT THE AIR CLEANER. I HAVE TRIED TO CLEAN THE AIR FILTER ELEMENT THE RESULT IS THE SAME, WHAT COULD BE THE PROBLEM?

Posted by on

Ad

1 Answer

  • Level 2:

    An expert who has achieved level 2 by getting 100 points

    MVP:

    An expert that gotĀ 5 achievements.

    Governor:

    An expert whose answer gotĀ voted for 20 times.

    Scholar:

    An expert who has written 20 answers of more than 400 characters.

  • Expert
  • 79 Answers

This means that you are over fueling. There is more fuel going to the carberator than air. By removing the air filter you are allowing more air flow into the carberator, which is allowing the engine to run right. Natural gas and propane generator must have no more than 11 inches of water column. Gasoline engines should have no more than 3.5 psi out of the electric pump. If gasoline is gravity fed, then this means that you need to rebuild the carberator or purchase a new carberator, but try to adjust the flow valve on the bowl of carberator first.

Posted on May 20, 2009

Ad

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of.(from cars to computers, handyman, and even drones)
click here to download the app (for users in the US for now) and get all the help you need.
Goodluck!

Posted on Jan 02, 2017

Ad

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Hello I have a kipor 3000 generator I cannot get it started, the generator was in storage and it just won't start can you help out


It helps that you said it was " in storage".
I am assuming the unit runs on gasoline.
If so, it is probable the gasoline has turned to gummy deposit and the carburetor must be rebuilt.
This is common with any gasoline engine that sits for a long period of time.
I have this problem with my 2 generators.
In the future, if this was the problem, the gasoline must be drained out at the very start of the "storage" time.
God bless your efforts.

Jul 15, 2016 | Kipor 3000 Watt Generator

1 Answer

My diesel kipor 5kva generator wont shut by key ,


Caution
the manufacture is recommending a cool down period of about 3 minutes to prevent overheating of the combustion chamber. the following is from the manufacture on shut down procedure.

3.2.8Check Stopping of Generating Set
(1)Disconnect the load from the generating set.
(2)Turn off the air switch of the generating set.
(3)Set the speed lever at RUN position, run the generating set without load for about 3 minutes. Do not stop the engine suddenly, otherwise the temperature will increase abnormally, the nozzle will blocked and the generating set will be damaged.
Press down the stop lever. Concerning the electric starter, turn the key to OFF. Turn the fuel **** lever to S position.
Pull out the recoil starter handle until you feel resistance (at this position, both intake/exhaust valve are closed.) and leave the handle in this position. This prevents the engine from rust.
If the engine keep on running even after the speed lever is placed at the STOP position, either turn the fuel **** to the CLOSE position or loosen the nut of high pressure fuel pipe on the pump side to stop the engine.
Do not stop the engine with the decompression lever.
Do not stop the generating set with load. Stop it after the load removed.

the following link provides the complete maintenance manual for the diesel generator
http://www.rcremers.nl/webshop/handleidingen?download=20:handleiding-aggregaat

Jan 12, 2016 | Kipor Electrical Supplies

1 Answer

Why unit keeps shutting down after it starts.


Your question is general without specific details. Any one of many things will cause your generator engine to stop running.

Is this question about a Kipor KDE5000TA? If so, your generator is powered by a diesel engine. There are safety shut downs built into the generator to protect the generator head and engine. Do you have any fault codes showing on your control panel display screen? (Trouble codes P-01 through P-05 will be displayed if there's a detected fault)

If you have no fault codes, then you likely have a fuel problem. Do the obvious:
  1. Visually check the fuel level in your tank. DO NOT rely on your fuel gauge. It may be stuck or otherwise not working.
  2. If you have fuel, check your fuel filter. It may be clogged. If your fuel filter is good, you may have water contamination.
  3. Drain your tank and refill with fresh #2 diesel fuel. I use "Diesel 911" with a biocide to prevent water contamination and bacteria growth in my fuel.
  4. Make certain your fuel oil supply and return lines are clear, not leaking, and the fittings are tight.
I know I'm shotgunning, peppering the target. However, I don't have enough information to zero in on a specific area where the problem could be. Good luck!

Apr 26, 2015 | Kipor Generator Diesel Kde5000ta

1 Answer

I have a Wacker portable Gen gs 5.6 It runs good but it also don't put out power ether


I suspect the inverter module has failed. The module failed on my kipor gen and produced the same problem, ie no A/C outpu. Module was about $300 for Kipor. Fitted myself, problem solved.

Dec 06, 2014 | Electrical Supplies

1 Answer

The generator shuts off after 30 minutes with an oil level alert but oil level if full


Your oil level sensor is bad. It needs to be replaced. If you unplug the wire leads to the sensor you may get the generator to run, but you'll have no low oil level/pressure protection. The oil level sensor is on the engine crankcase usually near the oil level dipstick. You'll likely see a small sensor with a couple of wires attached to it. To replace it, you'll need to drain your engine crankcase before removing the sensor.

Apr 06, 2014 | Kipor RV Generator Sinemaster IG3000

2 Answers

Oil and fuel mixing.


you need to clean out the sump air vent. and change the filter for the air breather. some are fitted with a clean easy filter you take off and wash out.

Jan 23, 2014 | Caterpillar 3306T Generator Set

1 Answer

I have a 18 hp b&s vanguard engine and it will only run on half choke any ideas


it,s not getting enough gas, your carburater needs cleaned and there's an mixture screw on most engine's hope this helps

Sep 22, 2012 | Briggs & Stratton Electrical Supplies

1 Answer

Kipor Diesel Genrator gives lotta smoke & consuming too much fuel


1- make sure the air filtr is clean
to make sure the problem is not from the air filter run witout air filter
2- there must be a ajustabe screww which controls the amount of fuel out put from the injector turn that screw and see the result .
3- make sure the engin is not burning oil . by checking the level of oil every 6 runing hours you can figuer this out
4- some smoke is normal with dissle engines

Oct 25, 2009 | Kitchen Appliances - Others

Not finding what you are looking for?
Kipor Parallel Wiring Kit, 30 amp Receptacle for IG2000P #66631 Logo

523 people viewed this question

Ask a Question

Usually answered in minutes!

Top Kipor Electrical Supplies Experts

jhnolson

Level 3 Expert

822 Answers

Jay Finke
Jay Finke

Level 3 Expert

1363 Answers

Chuck Graybill

Level 2 Expert

74 Answers

Are you a Kipor Electrical Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides