Question about Proview PL926WBi 19" LCD Monitor

2 Answers

Proview 900 series black flat panel monitor

I've had my monitor for over a year, and all of a sudden, the monitor is in hybernation mode. Blue power light blinks. That's all it does. It won't come on. In control panel, I made sure it's set on, "never turn off monitor", so I know the settings in the computer are set right.  Another monitor hooked up to the computer works fine. Any help? It's only  1 year old.

Posted by on

  • 1 more comment 
  • Anonymous Nov 03, 2007

    I have the same problem as allan mnf date 2-07 but it goes orange tint and bank can get a view for a few seconds by powering off then on again but same orange tint can't find a solution

  • Hydrodc1 Aug 08, 2008

    Well a solution is what I was looking for and have yet to find it. After only one year of use the Proview 900w just went black with the blue power light still on. Are Proview monitors nothing more than through away monitors and should I avoid them in the furture?

  • Anonymous Sep 01, 2008

    I have had my monitor for a little over than 1 year and it just when black on me. the blue ligth is still on but nothing else.

×

Ad

2 Answers

  • Level 1:

    An expert who has achieved level 1.

  • Contributor
  • 1 Answer

Same problem, and solution 1 given here fixed my Proview 900W. A few of the 470uF caps on the power board were oozing dielectric probably due to overheating. Hopefully the replacements will hang in there for a couple more years...

Posted on Dec 11, 2007

Ad

I had the same exact problem (Blue LED blinking but the monitor doesn't turn on), but I followed the guide that delphiuser posted in this post (http://www.fixya.com/support/t127735-white_screen) and replaced some capacitors in the power supply. (I'm the guest that posted on Nov. 15) The LCD is still working perfectly today. So.. if you have some electronic and soldering experience, you could save the LCD. You do want to be careful of the high voltage capacitor in the LCD (the big one on the power supply) when you have the LCD open though, that one can give you a REALLY nasty shock.

Posted on Nov 18, 2007

Ad

2 Suggested Answers

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi there,
Save hours of searching online or wasting money on unnecessary repairs by talking to a 6YA Expert who can help you resolve this issue over the phone in a minute or two.

Best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.

Here's a link to this great service

Good luck!

Posted on Jan 02, 2017

  • 6 Answers

SOURCE: proview 900 series black flat panel monitor

its sound you have bad inverter chip. The I.C. "BIT3193G" is the main controller in the inverter circuit. This chips is a surface mount chip and you must be careful remove it or you can damage the board. Also have you check for any burn out transistor?

Posted on Mar 21, 2009

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Proview Monitor PL926 Wbi The power indicator


Repair estimate will be according to problem.

Nov 13, 2009 | Proview PL926WBi 19" LCD Monitor

1 Answer

Monitor screen is black


bad capacitors on the power board internal to the monitor they need to be replaced.

Mar 02, 2009 | Proview PL913S 19" Flat Panel LCD Monitor

1 Answer

Proview 900 series black flat panel monitor


its sound you have bad inverter chip. The I.C. "BIT3193G" is the main controller in the inverter circuit. This chips is a surface mount chip and you must be careful remove it or you can damage the board. Also have you check for any burn out transistor?

Feb 21, 2009 | Computers & Internet

3 Answers

LCD display Proview


If the screen is pinkish chances are the panel is defective.Should follow-up with Company Proview and do some correspondence.
Samir

May 23, 2008 | Proview PL926WBi 19" LCD Monitor

2 Answers

PROVIEW FLAT SCREEN TFT 17" MONITOR


the vga mode not suppopt is on and not working

May 07, 2008 | Proview PL713S 17" Flat Panel LCD Monitor

1 Answer

Proview PRO576 error message "mode not supported" and will show nothing else


Okay, we got a fix by having another monitor hooked up to our computer and going in to display and changing the display settings to a lower setting. The screen resolution - turn it to lower - I guess somehow - the setting was too high for our monitor. Don't know how it changed itself though. Anyway, change it to a lower resolution then re-hook up your monitor and see if it works. The reslution can be pushed back up until you notice the problem again.

Mar 05, 2008 | Proview PRO576 15 in. Flat Panel LCD...

1 Answer

Doesnt power up


Most common problem is inverter board.

Dec 23, 2006 | Proview PL 566s 15" Flat Panel LCD Monitor

Not finding what you are looking for?
Proview PL926WBi 19" LCD Monitor Logo

Related Topics:

1,071 people viewed this question

Ask a Question

Usually answered in minutes!

Top Proview Computers & Internet Experts

Pieter Vleeshouwers
Pieter Vleeshouwers

Level 3 Expert

1944 Answers

ka4iup
ka4iup

Level 3 Expert

3960 Answers

Brad Brown

Level 3 Expert

17446 Answers

Are you a Proview Computer and Internet Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...