1 Answer

Wiring for a

Fedders Y Chassis AEY12F7E Air Conditioner?

Posted by on

  • 1 more comment 
  • merk09 May 15, 2009

    No it's digital AEY12F7E-D I had the cover going to change out the capacitor and a child pulled the wires all off just about everything and I do not have a wiring diagram for the unit 230v, It looks like L2 goes to the piggy backs to Hearn. L1 goes to the board everything works but the compressor, it works fine when hook to L1, L2 & hearn

  • merk09 May 16, 2009

    as it looks now the HEARN and L2 are piggy backed but off the condencer and it looks like L1 goes through board with a wire from there that can only reach C on the Capacitor. It's the L2 piggy back with (Compresor Hearn) that has me perplexed. Wired that way the compressor doesn't run.

  • Robert Moller
    Robert Moller May 11, 2010

    Do you have a rotaray type selector switch ?

×

1 Answer

  • Level 3:

    An expert who has achieved level 3 by getting 1000 points

    All-Star:

    An expert that got 10 achievements.

    MVP:

    An expert that got 5 achievements.

    Guru:

    An expert who has written 7 tips or uploaded 3 video tips

  • Master
  • 1,524 Answers

L1 to board to one side of thermostat.
Other side of thermostat to one side of compressor overload.
Other side of overload to (C) terminal on compressor.
Should work now.

Posted on May 15, 2009

  • 2 more comments 
  • Robert Moller
    Robert Moller May 16, 2009

    The thermostat is on this board ? Sorry Fedders now blocks everyone from their wiring diagrams.

  • Robert Moller
    Robert Moller May 16, 2009

    The only thing that should be on the Herm. terminal of the capacitor is the lead from the start (S) winding of the compressor.
    L2, one lead from fan, lead from run (R) winding on compressor.
    Those three to "C" terminal on capacitor.
    L1 to control to one side of thermostat. The other side of thermostat to one side of overload. The other side of overload to common (C) terminal on compressor. End of sentence.


  • Robert Moller
    Robert Moller May 16, 2009

    The only thing that should be on the Herm. terminal of the capacitor is the lead from the start (S) winding of the compressor.
    L2, one lead from fan, lead from run (R) winding on compressor.
    Those three to "C" terminal on capacitor.
    L1 to control to one side of thermostat. The other side of thermostat to one side of overload. The other side of overload to common (C) terminal on compressor. End of sentence.


  • Robert Moller
    Robert Moller May 16, 2009

    The only thing that should be on the Herm. terminal of the capacitor is the lead from the start (S) winding of the compressor.
    L2, one lead from fan, lead from run (R) winding on compressor.
    Those three to "C" terminal on capacitor.
    L1 to control to one side of thermostat. The other side of thermostat to one side of overload. The other side of overload to common (C) terminal on compressor. End of sentence.


×

1 Suggested Answer

6ya6ya
  • 2 Answers

SOURCE: I have freestanding Series 8 dishwasher. Lately during the filling cycle water hammer is occurring. How can this be resolved

Hi,
a 6ya expert can help you resolve that issue over the phone in a minute or two.
best thing about this new service is that you are never placed on hold and get to talk to real repairmen in the US.
the service is completely free and covers almost anything you can think of (from cars to computers, handyman, and even drones).
click here to download the app (for users in the US for now) and get all the help you need.
goodluck!

Posted on Jan 02, 2017

Add Your Answer

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1 Answer

Won't heat


Too vague. make and model of your A/c, split system or package?

Nov 16, 2012 | Fedders Y Chassis AEY12F7E Air Conditioner

1 Answer

This is a heating and cooling company looking for a heating element or fuse link. The unit is blowing cold air when on heating setting. Is the heating element behind the evaporator coil?


You're right. The eating element always be behind the evaporator coil.But check whether your unit model has heating and cooling or cooling only.

Dec 14, 2010 | Fedders Y Chassis AEY12F7E Air Conditioner

1 Answer

2 air conditioners won't start and they are not that old. have done the reset and don't know what else to do.


mcdevito75 here, If both units are on 1 fuse change it. In other words if the fuse keeps blowing change the electrical sockets 1 for each unit.

Jun 22, 2010 | Fedders Y Chassis AEY12F7E Air Conditioner

1 Answer

Blower lockes up when u turn it on but it spins freely when


mcdevito75 here, Fan Motor appears fine while running, once shut off won"t strart again, fan needs help in starting, If so replace, the fan motor. See your local A/C repair shop, they come to the house.

May 31, 2010 | Fedders Y Chassis AEY12F7E Air Conditioner

1 Answer

I have an error code e-1 on my aey12f7e-d


I can't get the Microsoft Security Essentials. Please help me to get it.

Dec 29, 2009 | Fedders Y Chassis AEY12F7E Air Conditioner

1 Answer

I have a Fedders air conditioner/heater and the it will not heat. Turned it on and fan was frozen and didn't turn it off in time. Bought new element but still nothing.


Are you sure the fan is frozen? Are you able to turn it freely by hand? These units have a limit switch in them to keep the fan from starting right away, normally about quarter size& 1/2" thick with 2 or more wires going to it. If the limit switch is bad it will keep the fan fo going on. May want to have a pro look at it.

Lee

Dec 18, 2009 | Fedders Y Chassis AEY12F7E Air Conditioner

1 Answer

My Feeders is on but doesn't cool.


mcdevito75 here, Sounds like the compressor will not kick in, usually the A/C unit will need a charge of freon gas, see your local A/C repair shop, they come to the house.

Aug 24, 2009 | Fedders Y Chassis AEY12F7E Air Conditioner

1 Answer

I have a thru the wall fedders ac unit. The heat stopped working when you turn it on it just hums.


no blower !!! or heating element is bad or switch try putting the fan on only if it works than it is probaly the switch not letting the blower on only heat

Apr 01, 2009 | Fedders Y Chassis AEY12F7E Air Conditioner

1 Answer

Heat doesn't work on ac unit


u have to be more specific. is it gas or electric. If electric check breaker first. Gas check thermocouple

Apr 01, 2009 | Fedders Y Chassis AEY12F7E Air Conditioner

1 Answer

Fedders Y Chassis Quit Running


Bummer. I bought an AEY08F2G that put out no warm air and very little cool air. Fedders filed chapter 11 in August. They do not honor warranties now, and apparently offer no repair service. I was fortunate that I bought mine from Venting Direct, and the unit was still within the 60 defective return period. They told me that Fedders units are junk. They provided full credit for the unit (plus shipping costs) without requiring that the unit be returned to them. My advice is to toss it. Live and learn.

Aug 26, 2007 | Fedders Y Chassis AEY12F7E Air Conditioner

Not finding what you are looking for?
Fedders Y Chassis AEY12F7E Air Conditioner Logo

Related Topics:

205 people viewed this question

Ask a Question

Usually answered in minutes!

Top Fedders Heating & Cooling Experts

Dan Webster
Dan Webster

Level 3 Expert

8220 Answers

Donni Steen

Level 3 Expert

659 Answers

Tony Pez

Level 1 Expert

9 Answers

Are you a Fedders Heating and Cooling Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...