You mean Expander Card.
The original chassis was fitted with only 6 slots and thus the control card can only manage these 6 slot single bandwidth. (2Meg per slot). As the 8 slot chassis was develop it was I think cheaper to build a new card as to build a new control card to manage the other two slot (7 and 8). So the expander card was build and to extend the shelf to 16 slots you do need the expander card fitted with a +16 expander module so that you can manage both chassis and provide double bandwidth per slot (4 Meg per slot).
There are two types of DNIC cards, nl. 6 circuit and 12 circuit. This card must be fitted with a DSP module if you want to configure the ports for 128K. Only 26XX DTU’s will work with this card. This card and DTU’s has been discontinued.
The 27LC2 card is a 6 circuit card and only 27XX and 2751/2/3 DTU’s will work with this card. This card and DTU’s has been discontinued.
The replacement for this card is the 27LC3 card and 27XX and 2751/2/3 DTU’s will work on them.
The 3600 mux is a single shelf which can be extended to a dual shelf. Each slot using a expander+16 can deliver 4 Meg. If only a single shelf is used you can fit a +8 module on the control card to provide you with 8 slots and 4 meg per slot.
Was this helpful?
Yes
No
Popular Solutions for Alcatel Newbridge MainStreet
can we incoperate adsl on newbridge ?can we configure newbrige mainstreet 3600 to opperate on adsl...
(More)
can we incoperate adsl on newbridge ?can we configure newbrige mainstreet 3600 to opperate on adsl platform?
Hello there, I'm looking manual for operation and manitenance to troubleshoot the DACS. Appreciate...
(More)
Hello there, I'm looking manual for operation and manitenance to troubleshoot the DACS. Appreciate your help in advance. Vijay.
on a mainstreet 3600+ oc-3 card what is the receive min/max levels and what is the wavelength band...
(More)
on a mainstreet 3600+ oc-3 card what is the receive min/max levels and what is the wavelength band sens. of the receiver (ie. 1280 nM to 1550nM ) ?
How to reset 90-0667-01 Controller Database to default setting I can't Access the spare controller...
(More)
How to reset 90-0667-01 Controller Database to default setting I can't Access the spare controller unit with an old passowrd.
When I Check for list of CPSS connected on my DXX node , I found one CPSS connected to Serial Port 1...
(More)
When I Check for list of CPSS connected on my DXX node , I found one CPSS connected to Serial Port 1 of chassis . Somebody before me has done this now he has left the job. Plz tell me why is this so . Is it necessary to connect CPSS to SP1